ESF-WH-070

2

3) Do not use an LED driver with this product.

4) NOT FOR USE WITH EMERGENCY LIGHTING.

1) Product should be installed by a qualified electrician. 

2) 

Switch off the power supply before commencing work, make sure all connections are secure before you power on.

For your and others safety please read the precaution carefully before installation:

Widely used in residential buildings, offices, shopping malls, supermarkets, hosptials, assembly lines, warehouses, etc. for 

energy saving illumination.

1.Product Features:

2.Product Applications:

Full glass housing: No Aging, Yellowing, Bending
Designed to work without a ballast

UL  certified

3.Installation Instructions:

Please follow all this instructions and notes, to ensure the product is installed and used in a safe manner.

Safety Precautions:

WARNING:

WARNING - Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of 

luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified 

electrician.

WARNING - Install this kit only in the luminaires that have the construction features and 

dimensions shown in the photographs and/or drawings and where the input rating of the 

retrofit kit does not exceed the input rating of the luminaire.

WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet 

metal or other sharp objects.

THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILI-

TY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. 

Do not make or alter any open holes in an enclosure of wiring or electrical components 

during kit installation.

Installers should not disconnect existing wires from lampholder terminals to make new 

connections at lampholder terminals. Instead installers should cut existing lampholder 

leads away from the lampholder and make new  electrical connections to lampholder lead 

wires by employing applicable connectors.

Summary of Contents for 23PL/H/LED/2G11 Series

Page 1: ...S A www westinghouselighting com WESTINGHOUSE and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation Used under license by Westinghouse Lighting All rights reserved Made...

Page 2: ...lation requires knowledge of luminaire electrical systems If not qualified do not attempt installation Contact a qualified electrician WARNING Install this kit only in the luminaires that have the con...

Page 3: ...L3 L2 N L1 The live hot wire can connect to either pin L1 L2 or L3 PL FLUORESCENT LAMP PL LED LAMP PL LED LAMP PL LED LAMP Electronic Ballast LINE The live hot wire can connect to either pin L1 L2 or...

Page 4: ...eight mm 23PL H LED 2G11 XX 620 x 600 x 80 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and...

Page 5: ...n de este equipo de Reacondicio namiento se necesita tener conocimientos de sistemas el ctricos Si no eres calificado no intentes instalarlo y contacta a un electricista calificado Advertencia Instal...

Page 6: ...al las connecciones L1 L2 o L3 Lampara Fluorescente PL Lampara LED PL Lampara LED PL Lampara LED PL Balasto electr nico Tension de Entrada Tension de Entrada El cable vivo tension de entrada se puede...

Page 7: ...cumple la Parte 15 de las Reglas FCC Su funcionamiento est sujeto a las dos siguientes condiciones 1 que este dispositivo no pueda producir interferencias da inas y 2 que este dispositivo debe aceptar...

Page 8: ...novation n cessite des connaissances dans le domaine des syst mes lectriques Si vous n tes pas qualifi n essayez pas de proc der l installation et contactez un lectricien qualifi AVERTISSEMENT Risque...

Page 9: ...Le fil sous tension peut tre connect la broche L1 L2 ou L3 PL lampe fluorescente PL Lampe LED PL Lampe LED PL Lampe LED Balast lectronique Ligne Le fil sous tension peut tre connect la broche L1 L2 o...

Page 10: ...D 2G11 XX 620 x 600 x 80 Luminaire r nov 3 lampe PL Lampe LED PL Lampe LED PL Lampe LED L3 L2 N L1 L3 L2 N L1 L3 L2 N L1 Le fil sous tension peut tre connect la broche L1 L2 ou L3 PL lampe fluorescent...

Reviews: