Bespoke Wall Mounted Extractor
Installation, Operating & Maintenance Instructions
W1826 SERNA EDGE 900 - 1100 (Energy Label Version) V1 20200803
Page 5
Westin
•
Electrical Installation
The extractor is a stationary appliance designed to be connected
by fixed wiring to the electrical supply. A competent electrical
technician must perform the electrical installation.
The hood must be fed from a 230Vac single phase electrical supply
using a switched spur fitted with a 3A fuse. The spur should be
located adjacent to the hood/cooker so that the supply can be
disconnected from the hood using the switch. The means of
disconnection from the supply must have a minimum contact
separation of 3mm in all poles. Alternatively, a means of
disconnection in the fixed wiring according to the relevant wiring
rules must be fitted.
A supply cord for connecting the spur to the extractor
is included.
The mains supply is connected to the free end of this cord as
follows:
INCOMING SUPPLY CORD CONNECTIONS
Core
Core Colour
Live
Brown
Neutral
Blue
Protective Earth
Green/Yellow
Make electrical connections for any remote motors, as described
earlier.
As a bespoke it may be that other electrical connections were
agreed for your hood, such as connections to control the lighting
from elsewhere or to operate other electrical devices. Make any
remaining electrical connections now.
Removing the Motor Transport Ties (If Fitted) (see fig.2)
Note: Transport Ties are only used on smaller appliances to protect
the motor during unpalletised transit.
Finalise Installation
Finish the installation by re-fitting any parts previously removed
and attach any chimney / cladding panels or parts supplied
separately.
ELECTRICAL HAZARD.
DISCONNECT ELECTRICAL SUPPLY BEFORE
PROCEEDING FURTHER
Fig. 2