Bespoke Wall Mounted Extractor
Installation, Operating & Maintenance Instructions
W1826 SERNA EDGE 900 - 1100 (Energy Label Version) V1 20200803
Page 11
Westin
To clean the stainless-steel surfaces of the extractor, use a soft
cloth and a suitable cleaning agent, such as a specially
produced stainless-steel cleaner or washing up detergent and
warm water.
Painted surfaces should be cleaned using a soft cloth,
detergent and warm water.
Glass surfaces should be cleaned with a suitable glass
cleaning agent.
Do not use abrasive cleaning materials or products.
Do not use bleach-based cleaning materials or
products.
Clean the grease filters in a dishwasher or by hand-washing in
hot water and detergent every 2 months - sooner if the extractor
is used extensively and filters become grease laden.
If your hood has mesh grease filters, you can expect years of
service from them however, they are considered a consumable
item and may deteriorate over time and need replacement,
particularly when cleaned in a dishwasher. For dishwasher
users adhering to a 2 monthly cleaning interval, we recommend
grease filter replacement every 5 years to maintain optimum
performance, even if they show no visible signs of deterioration.
For all users, filters should be replaced whenever they exhibit
signs of physical wear.
Removing the Grease Filters
Most Westin hoods are fitted with clip-in filters that have an
integrated sprung latch mechanism.
Release the latch by pulling the lever and remove the filter. The
filter is replaced by locating the fixed tabs opposite the lever
catch into corresponding slots in the baseplate and then
pushing the filter into position with the latch held open. Once
the filter is in position carefully release the lever, allowing the
latch to engage.
For units supplied with concealed filters, the filters are located
behind a hinged panel. This panel is held shut with magnetic
catches. Open the panel by grasping it in corners opposite the
hinged side.
LED replacement
The long-life LED units are not designed for end user
replacement. In the unlikely event of failure please call Westin
to arrange a Service Call.
Caring for HP4 high efficiency carbon filters
(Recirculating hoods only).
To restore and regenerate high efficiency HP4 carbon filters,
they must be washed in the dishwasher (without other dishes
or cookware) and then be placed into an oven for 1 hour at
max 90°C.
HP4 filters should be washed whenever they are dirty or lose
effectiveness (at least every two months).
Regular washing and regeneration will maximise the efficiency
and lifespan of these filters.
These filters can be regenerated repeatedly but are
considered a consumable and will eventually deteriorate, after
which they should be replaced. The time this takes will
depend on the style of cooking but they can be expected to
deliver excellent service under normal use conditions,
although replacement is recommended at least every two
years.
8.
SPECIFICATIONS
A 3A fuse for the electrical supply is usually sufficient. Units
with multiple fans fitted may require a 5A fuse.
In all cases, because this is a custom made product you
must refer to the rating plate inside the extractor and any
remote motor and consult with your electrician to
determine the correct electrical supply fuse required to
protect you, your property and the appliance.
If your unit has been supplied to work with a remote or
third party fan then you should consult the rating plate of
both the extractor and fan(s) in order to determine the
electrical load of the system and size your fuse
accordingly.
Electrical System - All Models
Supply voltage:
230V~ 50Hz
LED voltage (17.5w per strip)
12V
Total power:
See rating plate
Commonly Used Motor Specifications
(For unlisted motors see motor rating plate)
Units with Internal GPE800 Fan
Fan airflow in free air:
800 m
3
/hr
Fan power input:
275W
Fan spigot diameter:
150mm
Units with Internal EC220 Fan
Fan airflow in free air:
1,000 m
3
/hr
Fan power input:
150W
Units with SEM1 Inline Fan
Fan airflow in free air:
800 m
3
/hr
Blower power input:
275W
Units with SEM2 External Wall Fan
Fan airflow in free air:
1,000 m
3
/hr
Fan power input:
150W
Units with SEM7 External Wall Fan
SEM7 airflow, in free air: 200mm Dia Duct
1,700 m
3
/hr
SEM7 airflow, in free air: 150mm Dia Duct
1,500 m
3
/hr
Fan power input:
490W
Note: The fan has a 200mm diameter spigot and is supplied with a
reducer for connection to 150mm ducting.
Units with SEM8 Inline Fan
SEM8 airflow, in free air: 200mm Dia Duct
1,300 m
3
/hr
SEM8 airflow, in free air: 150mm Dia Duct
1,100 m
3
/hr
Fan power input:
250W
Note: The fan has a 200mm diameter spigot and is supplied with a
reducer for connection to 150mm ducting.
Do not install ducting smaller in diameter than that agreed
with Westin or than the extractor duct spigot diameter as
to do so will reduce performance and may damage the
product.
W S Westin Ltd, Phoenix Mills, Leeds Road,
Huddersfield, HD1 6NG, UK
Tel: 01484 421585 Fax: 01484 432420
Email: [email protected]