background image

WESTFIRE · WF

17

 · WF

18

 · WF

19

8

WESTFIRE · WF

17

 · WF

18

 · WF

19

9

MAINTENANCE

Ash must be removed from the stove at regular intervals.

The stove must be completely cold before being cleaned. The outside should be cleaned using a dry cloth. The
inside of the stove should be cleaned once a year. To clean the inside, remove all ash, soot and tar residue from
the combustion chamber. The smoke plate should be removed as dirt and soot will collect behind it. The packing
cord in the door will wear over time and should therefore be checked.

The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The
chimney must also be checked for blockages before relighting the stove if it has not been used for an extended
period of time.

The lacquer may wear thin in exposed places due to overheating. This, and other lacquer damage, may be
repaired using a special senotherm lacquer spray available at all stove outlets.

Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.

The combustion chamber is lined with Skamol. These panels will wear over time and will therefore need
replacing. The same is true for the smoke plate.

A Skamol panel may crack if hit too hard by a piece of firewood. This has no effect on the function of the stove
(this is not the case with the smoke plate). The Skamol panels will only need to be replaced once they become
very worn and are no longer whole, or if they crack in several places.

The air damper and the stove door must be closed in the event of overheating.

OPERATING PROBLEMS

Soot forms on the window: The firewood may be too wet, or the intake of secondary air may be insufficient.

The wood burns too quickly: The chimney draft may be too strong, or there may be a leak near the door of the stove.

The stove fails to heat fully: The firewood may be too wet.

Smoke or odour: Weak chimney draft – check for blockages in the flue pipe/chimney and check the height of the
chimney in relation to the surroundings.

Soot in the chimney: The firewood may be too wet, or the intake of secondary air may be insufficient.

GUARANTEE

Your new stove is covered by a five year guarantee against manufacturing defects.

Your 

receipt

 documents the

date of purchase.

The 

guarantee  does 

not 

cover 

damage

 caused by faulty operation such as overheating or the

stove being incorrectly connected, or damage which occurs as a result of external physical force.

The guarantee does not cover damage to replaceable parts, transport costs associated with repairs under warranty
or the installation/dismantling of the stove in connection with repairs under warranty.

Warning! Any unauthorised modification of the appliance is forbidden.
Only replacement parts recommended by Westfire ApS should be used for repairs.

UK 

UK

FIRE  BRICK 

INSTALLATION 

SEQUENCE - 

WESTFIRE UNIQ 

17/18/19

4.

8. 

7.

3.

5.

9.

Westfire Uniq 17,18 &19 completed fire chamber.

1) Fit Inner top turbulence baffle brick 10 – positioned on

secondary air pipe & between two retaining lugs on rear

panel of the fire chamber.

2) Fit rear brick 5 – push rear brick into place below stainless

steel tertiary air bar with the angled edge to the rear at

the bottom.

3) Fit base bricks 8, 7 either side of cast ash grate 6 and

fit metal spacer to front of stove. This should leave a 5mm

space for the log retail to fit into as the last procedure.

4) Fit side bricks 4 & 3 positioned on top base bricks 8 & 7.

5) Fit fire box baffle 2 (angled edge resting on the stainless

steel tertiary air bar) the baffle is supported with two metal

pins which fit into side bricks 4 & 3.

6) Slide log retainer 1 into positioned in front of base

bricks 8 & 7.

1.

6.

1.  Log retainer
2.  Firebox baffle
3.  Side brick right
4.  Side brick left
5.  Rear fire brick right
6.  Cast grate and Steel spacer
7.  Base brick right
8.  Base brick left
9.  Top turbulence baffle