28
Using
Cleaning and Storing
Clean the unit with a smooth and dry linen cloth. If necessary,
please moisten it slightly.
Clean the laser emitting window (L) only with a gentle air jet or, if
the unit is dirtier, use a slightly moistened cotton stick.
Do not use any solvents or aggressive chemicals for cleaning.
Remove batteries if the unit is not in use. Empty batteries may
discharge and damage the unit.
Protect the unit from dust and dirt.
Technical Data
Measuring Range
0.05 to 40 m
Accuracy
± 1.5 mm
Resolution
0.001 m
Measuring Speed
0.5 s
Laser
<1 mW, 650 nm
Laser Beam Size
25 mm at 30 m
Batteries
2x LR6 (AA)
Battery Life
for up to 10000 Measurements
Operating Temperature
-5 °C … +40 °C
Storing Temperature
-20 °C … +60 °C
Auto Shut-Off
Laser: after 30 s
Device: after 180 s
Dimensions
122 x 53 x 35 mm
Weight (w/o. Batteries)
117 g