Start-Up and Operation 

Installation Hints 

  Install the unit in the engine compartment of your car with the 

included cable ties and sheet-metal screws. Install it in a 
position where it is protected from splashing and dirt.  

  Conduct the wires in such a way that they can not come into 

contact with moving or hot parts (such as exhaust or cooling 
van). 

Caution!

 A connection between the high-voltage plates and 

the car body will cause a short circuit which will destroy the 
unit.  

Installation of the High-Voltage Plates 

  Install the plates (4) in such a way that the metal side of the 

plates (4) can not come into contact with electric components 
or other parts of your vehicle. The mounting holes in the plates 
(4) are intended for the cable ties or the sheet metal screws. 

Make sure

 the head of the screw cannot come into contact 

with the metal part of the plate (4). There is a danger of a short 
circuit! 

  Install the plates (4) in such a way that they are touched by a 

marten when it enters the engine compartment. The shock is 
triggered when the marten touches the car body and one of 
the 6 high-voltage plates (4). If possible, mount the plate (4) 
close to cables and hoses which are prone to marten attack.  

  There is no danger of sparking, but it is advisable to keep a 

distance of at least 5 mm between the cables and parts of the 
vehicle’s electric system. 

Advice 

If you run into problems when installing the marten shock, please 
consult a car repair shop or our customer support. 

Summary of Contents for 73 63 22

Page 1: ...Marderschock 12 V DC Artikel Nr 73 63 22 Marten Shock 12 V DC Article No 73 63 22 Bedienungsanleitung Instruction Manual...

Page 2: ...ehmen Sie sich die Zeit diese Bedienungsanleitung in Ruhe durchzulesen und bewahren Sie diese f r sp teres Nachlesen gut auf Sehr geehrte Damen und Herren Instruction manuals provide valuable hints fo...

Page 3: ...III bersicht Overview 1 2 4 3 5 6 7 1...

Page 4: ...ntroll LED Control LED 3 1 A Schutzsicherung 1 A Micro Fuse 4 Hochspannungspl ttchen 6 St ck High Voltage Plates 6 Pieces 5 Zuleitungskabel Pluspol Cable Plus 6 Zuleitungskabel zum Z ndschloss Connect...

Page 5: ...inweise Seite 7 Verlegung der Hochspannungspl ttchen Seite 7 Reinigung Seite 8 Allgemeine Tipps Seite 8 Technische Daten Seite 12 Safety Notes Page 3 Method of Operation Page 9 Electric Connection Pag...

Page 6: ...gesehenen Spannung Die Installation eine Reparatur oder andere Arbeiten wie z B Auswechseln einer Sicherung etc d rfen nur vom Fachmann durchgef hrt werden Ein Kontakt zwischen den Hochspannungspl ttc...

Page 7: ...nstallation repairs or other works such as changing a fuse etc may only be carried out by an appropriately trained skilled person Connecting the high voltage plates with the car body will cause a shor...

Page 8: ...ri e Les travaux d installation de r paration ou autre tels que Remplacement d un fusible etc ne doit tre effectu e par un sp cialiste Un contact entre la plaque haute tension et la masse du v hicule...

Page 9: ...ppropriata Il lavoro di installazione riparazione o di altro tipo come ad esempio Sostituzione di un fusibile ecc deve essere effettua ta solo da uno specialista Un contatto tra la piastra di alta ten...

Page 10: ...i Ber hrung einen schmerzhaften aber nicht t dlichen elektri schen Schlag Nach der Entladung baut sich die Ladung des Kondensators wieder auf und in dieser Zeit kann der Marder den Motorraum wieder ve...

Page 11: ...den Hochspannungspl ttchen 4 und der Fahrzeugmasse f hrt zu einem Kurzschluss der das Ger t zerst ren kann Verlegung der Hochspannungspl ttchen Verlegen Sie die einzelnen Pl ttchen 4 so dass die blank...

Page 12: ...leitungskabel Pluspol 5 entfernen sollten Die Entladung der Hochspannung erfolgt automatisch innerhalb von 60 Sekunden Allgemeine Tipps Wurde Ihr Fahrzeug bereits von Mardern besucht haben die Tiere h...

Page 13: ...hile the charge in the capacitor rebuilds the marten has time to es cape from the engine compartment This way the marten is not kept in place and killed by the current Electric Connection The marten s...

Page 14: ...ponents or other parts of your vehicle The mounting holes in the plates 4 are intended for the cable ties or the sheet metal screws Make sure the head of the screw cannot come into contact with the me...

Page 15: ...kely the animals have left their marks for the identification of their area These odours must unconditionally be removed before installing the marten shock Or other martens could even enter a bite pro...

Page 16: ...Hochspannung bei abgeschalteten Ger t Max 60 Sekunden Abmessungen 119 x 72 x 34 mm Gewicht komplett Ca 160 g Operating Voltage 12 V Function Range 10 15 V Voltage on the Plates 300 700 V Sound Pressu...

Page 17: ...festgelegt sind Hagen den 13 M rz 2012 Thomas Klingbeil Qualit tsbeauftragter We the Westfalia Werkzeugcompany Werkzeugstra e 1 D 58093 Hagen declare by our own responsibility that the product Marten...