SOP Title:
WT-
GERM KILLER™ 8910UVC BODYLight™ Operation
Effective Date:
10July2020
SOP Number:
WT-SOP-01007.05
Page:
7 of 17
Western Technology, Inc.
Confidential and Proprietary
10.
EQUIPMENT SPECIFICATIONS
10.1. UVC BODYLight Light Head with Battery Pack - ATM, BodyLight
10.1.1. Suitable for simultaneous use in Class I, Division 1 & 2, Group C, & D and
Class II, Division 1 & 2, Group E, F, & G locations; Zone 1 & 2 and Zone
20, 21 & 22.
10.1.2. Temp. Ambient: -20º to +40ºC. Temp. Rating: T5.
10.1.3. Conforms to UL Std. 153, 844, 62133.
10.1.4. Certified to CSA Std. 12, 137, 25, E62133.
10.1.5. Suitable for Wet Location Use. Type 6P.
10.2. BODYLight Battery Pack - ATM, BodyLight Lithium-Ion Battery Pack
10.2.1. Suitable for simultaneous use in Class I, Division 1 & 2, Group C, & D and
Class II, Division 1 & 2, Group E, F, & G locations; Zone 1 & 2 and Zone
20, 21 & 22.
10.2.2. Identification: 4INR19/66.
10.2.3. Output Power: 14.4VDC, 3.4Ah.
10.2.4. Temp. Ambient: -20º to +40ºC. Temp. Rating: T5.
10.2.5. Certified to UN 38.3.
10.2.6. Conforms to UL Std. 62133.
10.2.7. Certified to CSA Std. E62133.
10.2.8. Suitable for Wet Location Use. Type 6P.
10.3. Battery Charger - ATM, BodyLight Lithium-Ion Class 2 Battery Charger
10.3.1. Ordinary Location Class 2 Power Unit
10.3.2. Input Power: 110-220VAC, 50/60Hz.
10.3.3. Output Power: 16.8VDC, 1.625A.
10.3.4. Conforms to UL Std. 153, 1310.
10.3.5. Certified to CSA Std. C22.2 No. 223.
10.4. BODYLight Battery Pack Manifold - ATM, BodyLight
10.4.1. Suitable for simultaneous use in Class I, Division 1 & 2, Group C, & D and
Class II, Division 1 & 2, Group E, F, & G locations; Zone 1 & 2 and Zone
20, 21 & 22.
10.4.2. Output Power: 14.4VDC, 3.4Ah.
10.4.3. Temp. Ambient: -20º to +40ºC. Temp. Rating: T5.
10.4.4. Conforms to UL Std. 62133.
10.4.5. Certified to CSA Std. E62133.
10.4.6. Suitable for Wet Location Use. Type 6P.