Warning

1.In order to prevent fire or electric shock accident, do not expose the controller to the 
rain or humid environment. There are dangerous high-tension fittings inside the controller, 
therefore do not open the cover. Entrust the repairing work only to the qualified 
professional repairing personnel when repairing is required.
2.Without the clear approval from the controller manufacturer or its authorized units, any
change or alternation to this controller might bring various inconveniences to the users 
when in use.

Attention

1. Please read this operating instruction manual thoroughly, so as to allow you to master 
the correct use of this controller.
2. After reading this operating instruction manual, please keep it safe and for reference in 
the future. If repairing is required, please contact the local dealer or the technical service 
center of our company.

Notice

 

for

 

use

1. In case this controller is not used for a long time, please remove the power plug from 
the socket.
2. Before switching on the power, please make sure that all wirings and power cord have 
been connected accurately.
3. Please put this controller in a ventilated dry area. Prevent it from getting close to the 
heat source,put it away from direct sunlight, mechanical vibration, dampness and dusty 
environment, and prevent it from getting close to other thermal-radiating objects.

Dear Guest,
Thank you very much for purchasing our sanitary ware. To enable you to use this product 
safely and effectively, please read this installation and operation manual carefully before 
use.

1.Please ensure that the product installed reliable electric leakage protection device, the 
power plug contains earth line, and make sure it is reliable earth line. Check the protect 
system of leakage protection each time before use.
2.Do not turn on water pump, heat pump or air bubble pump without water.
3.Before turn on water pump, check if the water level over jets 10 to 20 mm or not, make 
sure regular usage of water pump otherwise it will be destroy because of water leakage.
4.People with Hypertension symptom, after drink or heart disease are not allowed to use
 the bathtub. Children have a bath must under adult's guidance.
5.During use please noticed that don't blocked the jets and avoiding the air adjustment 
valve overflowing. Also keep the bathtub clean and don't let it blocked by hair or mess.
6.During use, please firstly adjust the water temperature or it will be burned.
7.The bathtub is designed with ergonomic, rise and fall changes are quite big so during 
usage pay more attention of be slipped.
8.Please shut down the system when not to use.

Summary of Contents for SYM0502A

Page 1: ...MODEL SYM0502A INSTALLATIONINSTRUCTION MASSAGE BATHTUB MASSAGE BATHTUB...

Page 2: ...ir conditioning 6 pillow water pump 7 drainage 8 shower 13 CAUTIONS Heat pump and air bubble pump is required by customers 9 tap 10 drainage switch 11 hot water switch 12 shift switch 13 cold water sw...

Page 3: ...wood panel 2 Manual 150 450 450 1500 650 500 500 drainage CAUTIONS Heat pump and air bubble pump is required by customers cold water hot water tap shower SIZE 1800 1500 700mm 1800 900...

Page 4: ...urately 3 Please put this controller in a ventilated dry area Prevent it from getting close to the heat source put it away from direct sunlight mechanical vibration dampness and dusty environment and...

Page 5: ...ler otherwise it will not work or even burn out the controller 5 If it is halted accidentally please close and restart II Brief Introduction 1 Controller System Including 1 Control panel 1 2 Control b...

Page 6: ...troller is found can not be used please operate the code checking with following instruction Code checking procedure Power must be off to the bathtub before the below procedure Press the power icon on...

Page 7: ...ically at the same time the pump icon blinks When any time the system checks the water level achieves the setting value the icon stops blink and the pump starts to work 7 FM Radio 7 1 The FM frequency...

Page 8: ...ted by press and to choose from 1 18 all 18stations 7 5 5 When pressing and entering a certain function state within 5 S without pressing system will automatically exit that function operation state O...

Page 9: ...P N by pressing to choose nest song by pressing to choose the last song by press and next song and last song can also be chosen 9 5 When the blue tooth music is started pressing for 2S to play or paus...

Page 10: ...ed by illegal manufacturers must not be connected to the controller Unapproved dismantling and modification of the enclosed internal wiring are strictly prohibited It is not allowed to connect or plug...

Page 11: ...n be removed 3 install a new water pump Water Jets are not working 1 check the system whether is on 2 the impeller of water pump doesn t rotate 3 water pump is broken which caused by working without w...

Page 12: ...ularly in order to avoid troubles from crack of water pipes or blocked inside 6 If there are something such as hair stuck inside the jets then just to twist out the jets and remove it 7 To clean hydro...