IT
3.2
Object
Description
1
Housing
2
3
M5×13 pan head screw
No
Item
Type
1
Outdoor copper cable
• Conductor cross-section: 4-6 mm²
2
Outdoor copper cable
• Conductor cross-section: 4-6 mm²
3
• Conductor cross-section: 2.5-6 mm²
4
Meter/RS485
• Conductor cross-section: 0.14-1.5 mm²
Cable Specifications
Mounting
3.1
Step 1
Step 2
Step 3
Step 4
Step 5
1 0mm
6
12-18 mm
Direct
Sunlight
Rain
Exposure
Snow
Lay up
AVOID
3.
Installing
Installation Requirements
1. Please install the inverter(s) in places that can avoid
inadvertent contact.
2. Please install the inverter on solid/smooth surfaces.
3. The inverter(s) should not be installed near inflammable or
explosive objects.
!
1
2
3
Product Overview
1.
w
H
2
1
3
5
4
7
6
/RS485/DRED
Dimension:W×H×D=425×346×160mm
Packing List
Inverter
Mounting
Bracket
Mounting
Accessories
Documents
1
1
1
2
1
1
1
2.
!
Wi-Fi /GPRS stick
3.1.1 Use the mounting paper guide to mark holes on the wall,
Drill three holes in the marked position of 10mm diameter and 70mm depth
3.1.2 Fix the expansion bolts and mount the main bracket with the screws in mounting accessories
3.1.3 Attach the inverter to the mounting bracket. Mount the supporting bracket at the bottom of the inverter
3.1.4 Check both sides of heat sink and ensure the inverter is stably attached
3.1.5 Use M5 screw ( torque:2.5Nm ) to attach the heat sink fins to the munting bracket
3.1.6 It is recommended to attach an anti-theft lock to the inverter
5
DRED
CAT-5E, outdoor shielded cable
Standard for
/
568B
EIA TIA
• Cable outer diameter: approx. 9 mm
• cable maximum length 1000m
9
• Cable outer diameter: 5-8 mm
DC Plugs
or D4
MC4
W-HPT-3000 / W-HPT-4000 / W-HPT-5000 / W-HPT-6000
W-HPT-8000 / W-HPT-10000
EN
Quick Installation Guide
D