Leonardo Off-Grid 1kW/1500/24 GE-SL
User Manual
EN
7
PHOTOVOLTAIC CHARGE CONTROLLER SECTION
Leonardo Off-Grid 1kW/1500/24 GE is equipped with
PV charge controller with 4 independent MPPT inputs:
is a charge
controller for photovoltaic modules for lead electrochemical batteries of the OPzV or OPzS type.
For the correct recognition of the battery voltage performed at power up, it accordingly sets the appropriate charging
parameters as described in
Tab.1
.
Battery voltage measured at start-up
20.0V <Vbatt <32.0V
24V battery
Tab. 1 System Voltage Detection
Choice of the PV module
When choosing the configuration of the string of modules to be used in the system, it is necessary to strictly follow the
indications in the following table.
Thanks to the presence of the charge controller with MPPT charging circuit, the modules can be connected on
two
independent inputs
in order to ensure the best use of the whole power.
Nominal battery voltage
Features of PV modules
24V hermetic battery, charging
voltage in constant voltage phase
(ABSORPTION)
Vch = 28.8V at a temperature
of 25° C
60 cells Modules Si mono-crystalline / poly-crystalline for a typical
power of 230 - 270Wp
Connect minimum 2 modules in series for each PV input
, the
power for each input requires a minimum of 450 W up to a
maximum of 550 W.
Maximum short-circuit current: 13A for each input.
Maximum open circuit voltage: 150V for each input.
Tab.2 Choice of the PV module
NOTTE
BULK
ABSORPTION
FLOAT
NOTTE
V
float
V
ch
T
Abs.
Pic.7 Charging curve
The voltage levels that the controller imposes on the Vch, Vfloat of the battery are always referred to the nominal
temperature of 25° C. As the temperature changes, the voltages imposed by the controller also vary, as
recommended by the battery manufacturers; decreases by -48mV /°C for each increase of one degree of
temperature. The charge parameters shown in
Pic.7
, with factory defaults for OPzV OPzS batteries and nominal
voltage of 24V, equal to Vch = 28.8V and Vfloat = 27.6V.