Westermo Wolverine DDW-142-12VDC-BP User Manual Download Page 17

17

6642-22541

LED indicators

LED

Status

Description

ON

OFF

Product has no power.

GREEN

All OK, no alarm condition.

RED

Alarm condition, or until product has started up. (Alarm 
conditions are configurable, see WeOS Management Guide).

FLASH

Location indicator ("Here I am!"). Activated when connected 
to IPConfig Tool, or upon request from Web or CLI.

DC1

OFF

Product has no power.

GREEN

Power OK on DC1.*

RED

Power failure on DC1.

DC2

OFF

Product has no power.

GREEN

Power OK on DC2.*

RED

Power failure on DC2.

FRNT

OFF

FRNT disabled.

GREEN

FRNT OK.

RED

FRNT Error.

BLINK

Product configured as FRNT focal point.

RSTP

OFF

RSTP disabled.

GREEN

RSTP enabled.

BLINK

Product elected as RSTP/STP root switch.

USR1 

(only DDW-242-
12VDC-BP)

OFF

Configurable, see WeOS Management Guide.

GREEN
RED

LNK 
SHDSL ports  
Link indicator 
Port 1–2

OFF

No DSL link.

GREEN

DSL link established.

GREEN FLASH

DSL link negotiation.

YELLOW

Port alarm and no link. Or if FRNT or RSTP mode, port is 
blocked.

 

SHDSL ports 
Quality indicator 
Port 1–2

All OFF

No DSL link.

3 RED

Signal to noise value below 3 dB. Unstable DSL link.

1 GREEN

Signal to noise value 3–5 dB. Marginal DSL link.

2 GREEN

Signal to noise value 6–9 dB. Normal DSL link.

3 GREEN

Signal to noise value above 9 dB. Strong DSL link.

RD

OFF 

No serial data received.

GREEN FLASH

Serial data received.

TD

OFF 

No serial data transmitted.

GREEN FLASH

Serial data transmitted.

YELLOW FLASH Indicate error on RS-422/485 bus.

Copper ports Port 
1–2

OFF

No link.

GREEN

Link established.

GREEN FLASH

Data traffic indication.

YELLOW

Port alarm and no link. Or if FRNT, RSTP or Link Aggregation 
mode, port is blocked.

Note: Supply voltage levels must be ensured externally. A green LED may not guarantee a valid operating voltage level.

Summary of Contents for Wolverine DDW-142-12VDC-BP

Page 1: ...www westermo com DDW 142 242 12VDC BP Industrial Ethernet Extender...

Page 2: ...2 6642 22541...

Page 3: ...and users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications Software tools Related software tools...

Page 4: ...both environment and human health which could be caused by inappropriate disposal Product disposal Care recommendations Follow the care recommendations below to maintain full operation of the product...

Page 5: ...al injuries and or damages to the product The following levels are used Warning Hazardous voltage The product must be installed by qualified service personnel and built in to an apparatus cabinet or s...

Page 6: ...Replacing the internal fuse must only be performed by Westermo qualified personell Warning Reduce the risk of fire To reduce the risk of fire use only telecommunication line cords with a cable diamet...

Page 7: ...uipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or...

Page 8: ...1kHz sine 2700 6000 MHz Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz sine 0 15 80 MHz Ethernet ports 10 V 80 AM 1 kHz sine 0 15 80 MHz SHDSL ports 10 V 80 AM 1 kHz sine 0 15 80 MHz R...

Page 9: ...hours MIL HDBK 217F2 GB 25 C Vibration IEC 60068 2 64 random Operating 5 20 Hz 2 m s 20 500 Hz 3 dB oct 3 axis 3 30 min Shock IEC 60068 2 27 Operating 6 ms 1000 m s 6 directions 3 shocks direction Bum...

Page 10: ...d contains amazing serial connectivity capability from being able to simulate an old AT modem convert Modbus RTU to TCP or encapsulate serial data into an IP packet DDW 142 242 12VDC BP is incredibly...

Page 11: ...onnection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Connect the product using at least 18 AWG 0 75 mm wiring Shielded cable Not required External supply current capability for prop...

Page 12: ...ected to this port The cable shield should be properly connected 360 to an earthing point within 1 m from this port This earthing point should have a low impedance connection to the conductive enclosu...

Page 13: ...12 V Logic zero 1V Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 SHDSL Electrical specification ITU T G 991 2 Annex B Data rate 32 kbit s to 30 4 Mbit...

Page 14: ...To Send No 8 RTS In Request To Send Female Pin 1 Pin 8 Direction relative this product Ethernet connection TX 2 ports Position Direction Description No 1 In Out Transmitted Received data No 2 In Out T...

Page 15: ...used to connect to the CLI Command Line Interface The following steps needs to be taken 1 Connect the serial diagnostic cable to the console port use only Westermo cable 1211 2027 2 Connect cable to y...

Page 16: ...within the product see WeOS Management Guide An external load in series with an external voltage source is required for proper functionality For voltage current ratings see Interface Specification sec...

Page 17: ...RED LNK SHDSL ports Link indicator Port 1 2 OFF No DSL link GREEN DSL link established GREEN FLASH DSL link negotiation YELLOW Port alarm and no link Or if FRNT or RSTP mode port is blocked SHDSL port...

Page 18: ...nside an apparatus cabinet or similar It is recommended that the DIN rail is connected to ground Snap on mounting see figure Mounting the product with integrated DIN clip Removal Removing the product...

Page 19: ...e use of the product in full operating temperature range and service life When this product is operated at an ambient temperature above 60 C 140 F forced ventilation is required to not exceed Touch Te...

Page 20: ...uration of the product IPConfig tool This is a custom Westermo tool used for discovery of attached Westermo products Web Configuration of the product using the web browser CLI Configuration of the pro...

Page 21: ...set and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cable The ON LED will stop flashing This initiates the factory rese...

Page 22: ...REV D 6642 22541 2020 06 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Reviews: