background image

9

6619-2202

Interface specifications

**  To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m 

boundary to the rails and connected to this port. The cable shield should be properly connected (360°) to an 
earthing point within 1 m from this port. This earthing point should have a low impedance connection to the 
conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure 
should be connected to the earthing system of an installation and may be directly connected to the protective 
earth.

Power LV

Rated voltage

12 to 48 VDC or 12 to 34 VAC

Operating voltage

10 to 60 VDC or 10 to 42 VAC

Rated current

150 mA @ 12 VDC 
  70 mA @ 24 VDC 
  40 mA @ 48 VDC 
150 mA @ 12 VAC
  70 mA @ 24 VAC

Rated frequency

DC: –
AC: 48 – 62 Hz

Inrush current I

2

t 0.25 

A

2

s

Startup current*

0.30 A

peak

Polarity

Polarity independent

Isolation to

All other ports 3 kV

rms

 50 Hz 1 min

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

 (AWG 24-12)

Shielded cable

Not required

*  External supply current capability for proper startup

Public Switched Telephone Network (PSTN)

Electrical specification

Public Switched Telephone Network

Data rate

300 bit/s – 33.6 kbit/s

Protocol

Bell103,  Bell212, V.21, V.22, V.22Bis, V.23C, V.32, V.32Bis, V.34, V.90

Protection

Installation Fault Tolerant (up to ±60 V) 

Isolation to

Power port  3 kV

rms

 50 Hz 1 min

RS-232 2 

kV

rms

 50 Hz 1 min

Connection

RJ-11C 

Shielded cable

Not required

RS-232  

Electrical specification

EIA/TIA-232

Data rate

1 200 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits; 

Σ

 9-12 bits

Protocol

Transparent

Retiming

Yes

Transmission range

Cable length < 15 m

Isolation to

Power port  3 kV

rms

 50 Hz 1 min

RS-232 2 

kV

rms

 50 Hz 1 min

Connection

9-pin D-sub female (DCE) and Detachable screw terminal (DCE )

Connector size

Detachable screw terminal  0.2 – 2.5 mm

2

 (AWG 24 – 12) 

Shielded cable

Not required **

Conductive housing

Isolated to all other circuits 

Summary of Contents for TDW-33

Page 1: ...TDW 33 DIN rail Tele V 90 modem www westermo com Westermo Teleindustri AB User Guide 6619 2202...

Page 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Page 3: ...s voltage may occur within this unit when connected to power supply or TNV circuits Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warr...

Page 4: ...e the risk of fire use only No 26 AWG or lager telecommunication cable The USOC jack required RJ11 C and the REN is used to determine the number of devices that may be connected to a telephone line Ex...

Page 5: ...ommunication Inc 11200 Westheimer Suit 900 Houston TX 77042 TEL 713 240 0367 Connection to party line service is subject to state tariffs Contact the state public utility commission public service com...

Page 6: ...lied for this EC declaration of conformity No Title Issue EN 61000 6 2 Immunity for industrial environments 2 2001 EN 55024 Information technology equipment Immunity 1 1998 EN 61000 6 3 Emission stand...

Page 7: ...50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips and interruption EN 61000 4 29 DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 re...

Page 8: ...also has password protection dial back security and caller ID answering to ensure that only authorised users can communicate with the modem and any connected equipment The TDW 33 is ideal for industri...

Page 9: ...lation to All other ports 3 kVrms 50 Hz 1 min Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required External supply current capability for proper startu...

Page 10: ...5 Signal Ground SG No 4 Out Data Set Ready DSR 10 6619 2202 Position D sub Direction Description D sub description No 1 Out Data Carrier Direct DCD No 2 Out Received Data RD No 3 In Transmitted Data T...

Page 11: ...DCD signal is active modem has detected a carrier or the signal is set to always ON DTR Data terminal ready OFF DTR signal is inactive ON DTR signal is active REL Reliable mode OFF Reliable mode is OF...

Page 12: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Page 13: ...figure a TDW 33 any GSM ISDN or PSTN modem can be used The modem used to configure is referred as the local modem Please make sure that the remote TDW 33 is connected to the PSTN network and is powere...

Page 14: ...f DTR switches from low OFF to high ON AT W Save settings Switch DTR from OFF to ON The modem will now dial the phone number stored in the first location of the telephone number table AT Z0 nnn Set up...

Page 15: ...rce of the difficulty Below follows a list of commands that might resolve the problems The commands may of course be placed on one single command line if desired Configure the TDW 33 connected to the...

Page 16: ...n be chosen to fit the actual system requirement Configure the TDW 33 PSTN Network AT F Set the unit to factory default AT IPR 9600 DTE baudrate 9600 AT ICF 3 4 Character framing 8 data 1 stop parity...

Page 17: ...l and requests to TDW 33 Dial the number to TDW 33 CONNECT 9600 TDW 33 verifies the password to the passwords stored and if true compare dissconnects Operator system at TD 36 enters Password n3Y9kA6ot...

Page 18: ...Caller ID version is used Note that some implementations doesn t give the possibility to make a silent answer since the Caller ID is sent between first and second ring signal The modem in the calling...

Page 19: ......

Page 20: ...mo se Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Commun...

Reviews: