Interface specifications

Power

Rated voltage

12 to 48 VDC and 24 VAC

Operating voltage

10 to 60 VDC and 20 to 30 VAC

Rated current

300 mA @ 12 V 
150 mA @ 24 V 
  75 mA @ 48 V

Rated frequency

DC and 48 to 62 Hz

Inrush current I²t

0.2 A²s

Startup current*

1.0 Apeak

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

RS-232 and Status port

Connection

Detachable screw terminal

Connector size

0.75 – 2.5 mm

2

 (AWG 18 – 13) 

Connect the unit using at least 18 AWG (0.75 mm

2

) wiring

Shielded cable

Not required

* External supply current capability for proper startup

Status

 

Port type

Signal relay, changeover contacts

Rated voltage

Up to 48 VDC

Operating voltage

Up to 60 VDC

Contact rating

500 mA @ 48 VDC

Contact resistance

< 50 m

W

Isolation to

RS-232 and Power port

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

 (AWG 24 – 13)

Shielded cable

Not required 

Branch circuit protection (fuse) is required for this unit with rating not exceeding 20 A. 
Product should be connected to UL Listed power supplies rated 12 – 48 VDC, min 500 
mA or 24 VAC, min 500 mA or reliably grounded DC SELV source.

Summary of Contents for ODW-720-F1

Page 1: ...www westermo com ODW 720 F1 Fibre Optic Modem Industrial Converter RS 232 to Fibre Optic Link Point to Point applications...

Page 2: ...2 6651 2221...

Page 3: ...essed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Westermo reserves the right to revise this document or withdraw it at any t...

Page 4: ...potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product...

Page 5: ...product Hazardous voltage may occur when connected to a power supply WARNING PROTECTIVE FUSE It must be possible to disconnect manually from the power supply Ensure compliance to national installation...

Page 6: ...pal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring this product is disposed of correctly you will...

Page 7: ...n which case the user will be required to correct the interference at his own expense Agency approvals and standards compliance Type Approval Compliance EMC EN 61000 6 1 Immunity residential environme...

Page 8: ...freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radiated emission CISPR 16 2 3 Enclosure EN 61000 6 3 ANSI C63 4 FCC part 15 Conducted emission CISPR 16 2 1 AC power ports EN 61000 6 3...

Page 9: ...al RS 232 and a fibre optic link ODW 720 F1 can also be used to convert from RS 232 to RS 485 by using one ODW 720 F1 and one ODW 730 F1 Data rate up to 250 kbit s ODW 720 F1 converts data using rates...

Page 10: ...unit using at least 18 AWG 0 75 mm2 wiring Shielded cable Not required External supply current capability for proper startup Status Port type Signal relay changeover contacts Rated voltage Up to 48 VD...

Page 11: ...aratus and located close to rails Conductive housing Isolated to all other circuits and housings To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3...

Page 12: ...O 2 Common C 3 Open no contact with C when fibre optical links are in operation NC Position Direction Description Product marking 1 In Common voltage COM 2 In Voltage A VA 3 In Voltage B VB 4 In Commo...

Page 13: ...ical inter face OFF No data received on the electrical inter face RD Flash Data received on the optical interface and transmitted out on the electrical interface OFF No data received on the optical in...

Page 14: ...with ODW 720 F2 units please refer to the ODW 720 F2 user guide for details on how to configure the units S1 DIP switch ON 1 2 3 4 5 6 7 8 S1 1 S1 8 always OFF for point to point applications S2 DIP s...

Page 15: ...es from PLC master that are correctly received the ODW 720 F1 should be indicated by flashing TD LED Frames that are received via the fibre link will be transmitted to the PLC slave and indicated by f...

Page 16: ...ent fibre transceivers and connectors can be used RS 232 interface The RS 232 interface is a female 9 position D sub Pin assignments are compliance with the EIA RS 232 standard Status port The status...

Page 17: ...cing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be mounted...

Page 18: ...REV J 6651 2221 2021 05 Westermo Network Technologies AB Sweden Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Reviews: