6

6650-2223

Type tests and environmental conditions

Electromagnetic Compatibility

Phenomena

Test

Description

Level

ESD

EN 61000-4-2

Enclosure contact 

± 6 kV

Enclosure air

± 8 kV

RF field AM modulated 

IEC 61000-4-3

Enclosure

10 V/m 80% AM (1 kHz), 80 – 800 MHz
20 V/m 80% AM (1 kHz), 800 – 1000 MHz
20 V/m 80% AM (1 kHz), 1400 – 2700 MHz

RF field 900 MHz

ENV 50204

Enclosure

20 V/m pulse modulated 200 Hz, 900 ± 5 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports unbalanced

± 2 kV line to earth, ± 2 kV line to line 

Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Pulse Magnetic field

EN 61000-4-9

Enclosure

300 A/m, 6.4 / 16 μs pulse

Voltage dips 
and interruption

EN 61000-4-11

AC power ports

10 & 5 000 ms, interruption
200 ms, 40% residual voltage
500 ms, 70% residual voltage

Mains freq. 50 Hz

EN 61000-4-16

Signal ports

100 V 50 Hz line to earth

Mains freq. 50 Hz

SS 436 15 03

Signal ports

250 V 50 Hz line to line

Radiated emission 

EN 55022

Enclosure

Class B

FCC part 15

Class A

Conducted emission

EN 55022

AC power ports

Class B

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class A

Dielectric strength

EN 60950

Signal port to all other 
isolated ports

2 kVrms 50 Hz 1min

Power port to other
isolated ports

3 kVrms 50 Hz 1min
2 kVrms 50 Hz 1min (@ rated power < 60V)

Environmental

Temperature

Operating

–40 to +70°C

Storage & Transport

–40 to +70°C

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz 
2 g, 8 – 500 Hz

Shock

IEC 60068-2-27

Operating

15 g, 11 ms

Packaging

Enclosure

UL 94

PC / ABS

Flammability class V-1

Dimension W x H x D

35 x 121 x 119 mm

Weight

0.26 kg

Degree of protection

IP 21

Cooling

IEC 529

Enclosure

Convection

Mounting

Horizontal on 35 mm DIN-rail

Summary of Contents for ODW-621

Page 1: ...Industrial Converter Serial RS 232 to fibre optic link Point to point applications www westermo com Westermo Teleindustri AB User Guide 6650 2223 ODW 621 Fibre Optic Modem...

Page 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Page 3: ...regulations However the user is warned not to look directly into fibre optical port or any connected fibre Care recommendations Follow the care recommendations below to maintain full operation of the...

Page 4: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses an...

Page 5: ...lity EMC References of standards applied for this EC declaration of conformity No Title Issue EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signalling and...

Page 6: ...ion 200 ms 40 residual voltage 500 ms 70 residual voltage Mains freq 50 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radi...

Page 7: ...communication via fibre optical network Serial interface asynchronous mode LC 2 Multimode LC connectors 5 km 3 1 miles LC 15 Singlemode LC connectors 15 km 9 3 miles LC 40 Singlemode LC connectors 40...

Page 8: ...scription OVP Over Voltage Protection OCP Over Current Protection Converter serial interface optical fibre ODW 621 is a fibre optic modem that converts between electrical RS 232 and a fibre optic link...

Page 9: ...o units depends on selected fibre transceiver and fibre type Distance up to 80 km 50 miles are available Note The Bi di transceivers must always be used in pair see example TX 1310 nm RX 1310 nm RX 15...

Page 10: ...al is set as long as the fibre link is in operation ready to transfer data The data set ready DSR signal is set as long as the ODW 621 is in service If RTS CTS is set to OFF will CTS always be set to...

Page 11: ...1 Baud rate Baud rate in bit s The system delay when transferring data from the serial input at one ODW 621 to the serial output of other one is calculated by adding the following 1 Fibre The optical...

Page 12: ...5 mm2 AWG 24 12 Shielded cable Not required To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port T...

Page 13: ...optic link is determined by the differ ence between the transmitter s output optical power min and the receiver input sensitivity max FX Fibre Bi di LC 60 Bi di LC 40 Bi di LC 20 Bi di MM LC 2 Fibre c...

Page 14: ...n Description Product marking 1 In Common voltage COM 2 In Voltage A VA 3 In Voltage B VB 4 In Common voltage COM Position Direction Description Product marking 1 NO Contact with C when fibre opti cal...

Page 15: ...port Data will be transmitted to the fibre link OFF RD Fibre link data Receive Flashing Receive data on the fibre link This frame is transmitted to the serial port OFF FL R Red Failure Link Remote ON...

Page 16: ...unding point e g use of wrist strap Note Disconnect power before DIP switch settings S2 S1 S1 DIP switch ON 1 2 3 4 5 6 7 8 CTS always active ON 1 2 3 4 5 6 7 8 RTS signal will be transferred to remot...

Page 17: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Page 18: ...ive ODW 621s Frames from PLC master that are correctly received the ODW 621 should be indicated by flashing TD LED Frames that are received via the fibre link will be transmitted to the PLC slave and...

Page 19: ......

Page 20: ...mo se Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Commun...

Reviews: