background image

5

6650-2223

Declaration of Conformity

 
 

Westermo Teleindustri AB 

 

 

Declaration of conformity

 

 

Org.nr/

Postadress/Postal address

 

Tel.

 

Telefax

 

Postgiro

 

Bankgiro

 

Corp. identity number

 

Registered office 

S-640 40  Stora Sundby 

016-428000 

016-428001 

52 72 79-4 

5671-5550 

556361-2604 

Eskilstuna 

Sweden 

Int+46 16428000 

Int+46 16428001 

 

 

 

 

 

 
 

The manufacturer

 

Westermo Teleindustri AB 

 

SE-640 40 Stora Sundby, Sweden 

 

Herewith declares that the product(s) 

Type of product 

Model 

Art no 

Industrial fiberoptic repeaters/media 
converters 

ODW-600 Series 
 

3650-0xxx 
 

 

is in conformity with the following EC directive(s). 
No Short 

name 

 

2004/108/EC Electromagnetic 

Compatibility 

(EMC) 

 

References of standards applied for this EC declaration of conformity. 
No Title 

 

Issue 

EN 50121-4 

Railway applications – Electromagnetic compatibility 
– Emission and immunity of the signalling and 
telecommunications apparatus 

2006 

EN 55022 

Information technology equipment - Emission 

2006 +A1:2007 

EN 55024 

Information technology equipment - Immunity 

1998 +A1:2001 
+A2:2003 

EN 61000-6-1 

Electromagnetic compatibility – Immunity for 
residential environments 

2007 

EN 61000-6-2 

Electromagnetic compatibility – Immunity for 
industrial environments 

2005 

EN 61000-6-3 

Electromagnetic compatibility – Emission for 
residential environments 

2007 

EN 61000-6-4 

Electromagnetic compatibility – Emission for 
industrial environments 

2007 

The last two digits of the year in which the CE marking was affixed: 

09 

 

 

Pierre Öberg 
Technical Manager 
29th September 2009 

 

Summary of Contents for ODW-621

Page 1: ...Industrial Converter Serial RS 232 to fibre optic link Point to point applications www westermo com Westermo Teleindustri AB User Guide 6650 2223 ODW 621 Fibre Optic Modem...

Page 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Page 3: ...regulations However the user is warned not to look directly into fibre optical port or any connected fibre Care recommendations Follow the care recommendations below to maintain full operation of the...

Page 4: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses an...

Page 5: ...lity EMC References of standards applied for this EC declaration of conformity No Title Issue EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signalling and...

Page 6: ...ion 200 ms 40 residual voltage 500 ms 70 residual voltage Mains freq 50 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radi...

Page 7: ...communication via fibre optical network Serial interface asynchronous mode LC 2 Multimode LC connectors 5 km 3 1 miles LC 15 Singlemode LC connectors 15 km 9 3 miles LC 40 Singlemode LC connectors 40...

Page 8: ...scription OVP Over Voltage Protection OCP Over Current Protection Converter serial interface optical fibre ODW 621 is a fibre optic modem that converts between electrical RS 232 and a fibre optic link...

Page 9: ...o units depends on selected fibre transceiver and fibre type Distance up to 80 km 50 miles are available Note The Bi di transceivers must always be used in pair see example TX 1310 nm RX 1310 nm RX 15...

Page 10: ...al is set as long as the fibre link is in operation ready to transfer data The data set ready DSR signal is set as long as the ODW 621 is in service If RTS CTS is set to OFF will CTS always be set to...

Page 11: ...1 Baud rate Baud rate in bit s The system delay when transferring data from the serial input at one ODW 621 to the serial output of other one is calculated by adding the following 1 Fibre The optical...

Page 12: ...5 mm2 AWG 24 12 Shielded cable Not required To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port T...

Page 13: ...optic link is determined by the differ ence between the transmitter s output optical power min and the receiver input sensitivity max FX Fibre Bi di LC 60 Bi di LC 40 Bi di LC 20 Bi di MM LC 2 Fibre c...

Page 14: ...n Description Product marking 1 In Common voltage COM 2 In Voltage A VA 3 In Voltage B VB 4 In Common voltage COM Position Direction Description Product marking 1 NO Contact with C when fibre opti cal...

Page 15: ...port Data will be transmitted to the fibre link OFF RD Fibre link data Receive Flashing Receive data on the fibre link This frame is transmitted to the serial port OFF FL R Red Failure Link Remote ON...

Page 16: ...unding point e g use of wrist strap Note Disconnect power before DIP switch settings S2 S1 S1 DIP switch ON 1 2 3 4 5 6 7 8 CTS always active ON 1 2 3 4 5 6 7 8 RTS signal will be transferred to remot...

Page 17: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Page 18: ...ive ODW 621s Frames from PLC master that are correctly received the ODW 621 should be indicated by flashing TD LED Frames that are received via the fibre link will be transmitted to the PLC slave and...

Page 19: ......

Page 20: ...mo se Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Commun...

Reviews: