RS-232
Electrical specification
EIA RS-232
Data rate
50 bit/s - 115.2 kbit/s
Data format
7 or 8 data bits, odd, even or none parity, 1 or 2 stop bits
Protocol
Transparent, optimised by packing algorithm
Circuit type
SELV
Transmission range
15 m/49 ft
Isolation
To all other ports
Connection
RJ-45 according to EIA-561
Shielded cable
Recommended
Conductive chassis
Yes
Number of ports
1
RS-232/422/485
Electrical specification
Configurable for EIA RS-232 or EIA RS-422/485
Data rate
RS-232
50 bit/s - 115.2 kbit/s
RS-422/485
50 bit/s - 2 Mbit/s
Data format
7 or 8 data bits, odd, even or none parity, 1 or 2 stop bits
(2 stop bits only when no parity is set)V
Circuit type
TNV-1
Transmission range
RS-232
15 m/49 ft
RS-422/485
Up to 1200 m/0.74 mi, depending on data rate and cable
type
Isolation
To all other ports
Connection
RS-232
RJ-45 according to EIA-561
RS-422/485
RJ-45
Shielded cable
RS-232
Recommended
RS-422/485
Shielded cable not required, except when installed in
Railway application as signalling and telecommunications
apparatus and located close to rails
a
Conductive chassis
Yes
Number of ports
1
a
To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.
22
Lynx L106-S2 and L206-S2