background image

RS-232

Electrical specification

EIA RS-232

Data rate

50 bit/s - 115.2 kbit/s

Data format

7 or 8 data bits, odd, even or none parity, 1 or 2 stop bits

Protocol

Transparent, optimised by packing algorithm

Circuit type

SELV

Transmission range

15 m/49 ft

Isolation

To all other ports

Connection

RJ-45 according to EIA-561

Shielded cable

Recommended

Conductive chassis

Yes

Number of ports

1

RS-232/422/485

Electrical specification

Configurable for EIA RS-232 or EIA RS-422/485

Data rate

RS-232

50 bit/s - 115.2 kbit/s

RS-422/485

50 bit/s - 2 Mbit/s

Data format

7 or 8 data bits, odd, even or none parity, 1 or 2 stop bits
(2 stop bits only when no parity is set)V

Circuit type

TNV-1

Transmission range

RS-232

15 m/49 ft

RS-422/485

Up to 1200 m/0.74 mi, depending on data rate and cable
type

Isolation

To all other ports

Connection

RS-232

RJ-45 according to EIA-561

RS-422/485

RJ-45

Shielded cable

RS-232

Recommended

RS-422/485

Shielded cable not required, except when installed in
Railway application as signalling and telecommunications
apparatus and located close to rails

a

Conductive chassis

Yes

Number of ports

1

a

To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.

22

Lynx L106-S2 and L206-S2

Summary of Contents for Lynx L106-S2

Page 1: ...www westermo com OS Lynx L106 S2 and L206 S2 Industrial Ethernet 6 Port Device Server Switch ...

Page 2: ... Conformity 8 3 Product Description 9 3 1 Product Description 9 3 2 Available Models 9 3 3 Hardware Overview 10 3 4 Connector Information 11 3 4 1 Ethernet Connection TX 11 3 4 2 Power Input 11 3 4 3 I O Connection 11 3 4 4 RS 232 Connection DCE 12 3 4 5 RS 422 485 Connection 13 3 4 6 Connection to the Console Port 14 3 4 7 USB Connection 14 3 5 LED Indicators 15 3 6 Dimensions 16 4 Installation 1...

Page 3: ...termo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source Software FLOSS The spec...

Page 4: ...dous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No personal ...

Page 5: ...ross sectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DIN rail must be connected to protective earth Upon removal of the product ensure that the protective earthing conductor or the connection to earth via the DIN rail is disconnected last WARNING HAZARDOUS VOLTAGE Do not open an energized product Hazardous voltage may occur when connected to a ...

Page 6: ...ecome hot When it is operated at high temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard CAUTION CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES There may be a requirement on the minimum temperature rating of the cable to be connected to the field wiring terminals see Interface Specifications 2 3 Care Recommendation...

Page 7: ...Immunity residential environments EN IEC 61000 6 2 Immunity industrial environments EN IEC 61000 6 3 Emission residential environments EN IEC 61000 6 4 Emission industrial environments EN 50121 4 IEC 62236 4 Railway signalling and telecommunications apparatus Safety EN IEC UL 60950 1 IT equipment Marine DNV GL rules for classification Ships and offshore units Table 2 Agency approvals and standards...

Page 8: ...ording to IEC 60068 2 60 method 3 This means that the product meets the requirements to be placed in an environment classified as ISA S71 04 class G3 CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated connector pins 2 5 4 Simplified De...

Page 9: ...rature range of 40 to 70 C 40 to 158 F can be achieved with no moving parts or cooling holes in the case The Lynx series has been tested both by Westermo and external test institutes to meet many EMC isolation vibration and shock standards all to the highest levels suitable for heavy industrial environments and rail trackside applications WeOS has been developed by Westermo to offer cross platform...

Page 10: ... connection 4 I O connection 5 Ethernet connection 6 RS 232 connection Figure 3 Location of interface ports and LED indicators 3 2 1 No Description No Description 1 I O connection 2 Console port 3 Accessorie cable art no 1211 2027 Figure 4 Location of interface ports bottom view 10 Lynx L106 S2 and L206 S2 ...

Page 11: ...escription 1 2 3 4 1 DC1 Input Supply voltage 2 DC2 Input Supply voltage 3 COM Input Common 4 COM Input Common Table 4 Power input Lynx supports redundant power connection The positive inputs are DC1 and DC2 the negative input for both supplies are COM Connect the primary voltage e g 24 VDC to the DC1 pin and return to one of the COM pins on the power input 3 4 3 I O Connection Illustration Pin no...

Page 12: ... opto isolated digital input which can be used to monitor external events For voltage current see Interface Specification section External load Status V V Digital in Lynx 3 4 1 2 Figure 5 Digital in 3 4 4 RS 232 Connection DCE Illustration Pin no Signal Direction Description Pin 8 Pin 1 1 DSR Out Data Set Ready 2 DCD Out Data Carrier Detect 3 DTR In Data Terminal Ready 4 SG Signal Ground not chass...

Page 13: ... used 5 Not used 6 R In RS 422 Receive 7 Not used 8 Not used Table 7 RS 422 485 connection Lynx is equipped with with an internal termination that is configurable through software in RS 422 485 mode The following termination schemes are supported No termination Rx Terminate Rx Terminate Tx Tx Rx Tx Rx Tx Rx Tx Terminate Tx and Rx Figure 6 RS 422 termination scheme No termination Termination Figure...

Page 14: ...ble 1211 2027 2 Connect cable to your computer USB port if drivers are needed they can be downloaded from the Westermo web 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information about the CLI see the WeOS Management guide Accessories Description Art no Westermo console cable 1211 2027 RJ45 to terminal block 1200 2490 RJ45 to DB9 cab...

Page 15: ...DC2a RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Product configured as FRNT focal point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Product selected as RSTP STP root switch USR1 Configurable see WeOS Management Guide Rx TD TD OFF No serial data received GREEN FLASH Serial data received Tx RD RD OFF No serial data transmitted GREEN FLASH Serial data transm...

Page 16: ...3 6 Dimensions Dimensions are stated in mm and are regardless of Lynx model 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1 Figure 8 Dimensional drawing 16 Lynx L106 S2 and L206 S2 ...

Page 17: ...mended that the DIN rail is connected to ground Snap on the product to the DIN rail according to the figure Figure 9 Mounting of product 4 2 Removal of Product This product has an integrated DIN clip To remove the product press down the support at the back with a screwdriver and lift it off the DIN rail Figure 10 Removal of product Lynx L106 S2 and L206 S2 17 ...

Page 18: ...e unit WeConfig tool This is a custom Westermo tool used for discovery of attached Westermo product Web Configuration of the product using the web browser CLI Configuration of the product via the Command Line Interface Username admin Password westermo If the computer is located in the same subnet as the switch you can easily use a web browser to configure the product Within the web you can configu...

Page 19: ...assword character NOTE Note Version of WeConfig tool must be 10 3 0 or higher 4 6 Factory Default It is possible to set the product to factory default settings by using two straight standard Ethernet RJ 45 cables 1 Power off the product and disconnect all Ethernet cables copper and fibre 2 Connect one Ethernet cable between Ethernet ports 1 and 4 and the other between Ethernet ports 2 and 3 The po...

Page 20: ...roduct will restart with factory default settings When the product has booted up the ON LED will show a green light and is now ready to use To boot as normal To skip the factory reset process just wait for approximately 30 seconds after the ON LED starts flashing RED without unplugging the Ethernet cables The product will conduct a normal boot with the existing settings 20 Lynx L106 S2 and L206 S2...

Page 21: ...al Conductor cross section 0 2 2 5 mm AWG 24 12 Stripping length cable 7 mm Tightening torque terminal screw 0 5 0 6 Nm Tightening torque screw flange 0 3 Nm Shielded cable Not required aRecommended external supply current capability for proper startup Ethernet TX Electrical specification IEEE std 802 3 Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type T...

Page 22: ...ven or none parity 1 or 2 stop bits 2 stop bits only when no parity is set V Circuit type TNV 1 Transmission range RS 232 15 m 49 ft RS 422 485 Up to 1200 m 0 74 mi depending on data rate and cable type Isolation To all other ports Connection RS 232 RJ 45 according to EIA 561 RS 422 485 RJ 45 Shielded cable RS 232 Recommended RS 422 485 Shielded cable not required except when installed in Railway ...

Page 23: ...To all other ports Connector Detachable screw terminal Conductor cross section 0 14 1 5 mm AWG 28 16 Stripping length cable 7 mm Tightening torque terminal screw 0 22 0 25 Nm Tightening torque screw flange 0 3 Nm USB Electrical specification USB 2 0 host interface Data rate Up to 12 Mbit s full speed mode Circuit type SELV Maximum supply current 400 mA Connection USB receptable connector type A Co...

Page 24: ...V 42 Ω 0 5 µF Power frequency magnetic field EN 61000 4 8 Enclosure 300 A m 0 16 7 60 Hz 1000 A m 50 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m at 80 2700 MHz 10 V m at 2 7 6 GHz 1 kHz sine 80 AM Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet Status out Digital in Serial ports Earth port Radiated R...

Page 25: ... 10 years MTBF MIL C217F2 Parts count Ground benign 25 C 593 000 hours Vibration IEC 60068 2 6 sine Operational 3 13 2 Hz 1 mm 13 2 100 Hz 0 7 g 5 5 30 Hz 1 5 g 30 50 Hz 0 42 mm 50 500 Hz 4 2 gb IEC 60068 2 64 random Operational 5 20 Hz 2 m2 s2 20 2000 Hz 3 dB oct Shock IEC 60068 2 27 Operational 30 g 11 ms 100 g 6 msb Bump IEC 60068 2 27 Operational 10 g 11 ms Enclosure EN 60950 1 Zinc Fire enclo...

Page 26: ... updated from brown to blue new information structure throughout the manual 1 2 About This Guide new chapter 2 Safety and Regulations entire chapter updated 3 1 Product Description updated 3 2 Available Models new chapter 4 1 Mounting updated 4 2 Removal of Product updated 26 Lynx L106 S2 and L206 S2 ...

Page 27: ...Lynx L106 S2 and L206 S2 ...

Page 28: ...Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6643 2240 REV I 2020 10 Westermo Network Technologies AB Sweden ...