When the unit is powered off or during reboot, any internal termination will be
disconnected from the signal lines.
NOTE
NOTE - The port is configurable for both RS-232 and RS-422/485, hence
no fail-safe biasing is available for RS-422/485 signals.
3.4.6. Connection to the Console Port
The console port can be used to connect to the CLI (Command Line Interface).
1. Connect the serial diagnostic cable to the console port (use only Westermo cable
1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can be
downloaded from the Westermo web).
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1) to
the assigned port.
For more information about the CLI, see the WeOS Management guide.
Accessories
Description
Art. no.
Westermo console cable
1211-2027
RJ45 to terminal block
1200-2490
RJ45 to DB9 cable
1211-2210
Table 8. Accessories table
3.4.7. USB Connection
Illustration
Pin
no.
Direction
Description
1
Out
VBUS
2
In/Out
D-
3
In/Out
D+
4
Out
GND
5
In/Out
Connected to
protective earth
Table 9. USB connection
14
Lynx L106-S2 and L206-S2