Summary of Contents for 3642-0240

Page 1: ...www westermo com Westermo Teleindustri AB User Guide 6642 22303 Industrial Ethernet SHDSL extender DDW 225 DDW 225 W O LV E R I N E S E R I E S WeOS...

Page 2: ...ty or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of...

Page 3: ...o fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or sha...

Page 4: ...nce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference...

Page 5: ...ity No Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity for residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6...

Page 6: ...N 61000 4 29 DC power ports 10 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage Radiated emission CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class A and Class B...

Page 7: ...tatus 3 IO Digital in Uin 60 VDC max Uin 10 mA max 4 IO Digital in M5 threaded hole for PE connection Position Direction descripton Input Output values 1 In out GND U 3 3 VDC max I 24 mA max 2 Out Tx...

Page 8: ...of advanced diagnostic functions that allow the SHDSL line to be dynamically monitored allowing alarms to be configured to pre warn of any performance issues This monitoring data can be accessed in a...

Page 9: ...polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required External supply current capab...

Page 10: ...LV Maximum supply current 500 mA Isolation to All other except Console Galvanic connection to Console Connection USB receptacle connector type A Conductive housing Yes Connection to console port The c...

Page 11: ...ocated close to rails Conductive housing Yes Number of ports 4 To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer...

Page 12: ...2 wire Receive Transmit SHDSL 2 In Out 2 wire Receive Transmit SHDSL Position Direction Description 1 2 3 4 1 Out Status 2 Out Status 3 In Digital in 4 In Digital in Direction relative this unit Posit...

Page 13: ...cription 1 Out VBUS 2 In Out D 3 In Out D 4 Out GND Shield In Out Connected to PE Console see more information on page 14 Position Direction Description 1 In Out TD 2 In Out TD 3 In Out RD 4 Not conne...

Page 14: ...ED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch VPN OFF VPN disabled GREEN Configurable Default At least on...

Page 15: ...N rail TH 35 15 according to EN 60715 CLICK Wall mounting This unit can also be wall mounted see figure Earth connection For correct function the ground connection on the unit needs to be properly con...

Page 16: ...the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Con...

Page 17: ...o ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables T...

Page 18: ...18 6642 22303...