background image

However, there is no guarantee that interference will not occur in a particular installation.
If this product does cause harmful interference to radio or television reception, which can
be determined by turning the product off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna
• Increase the separation between the unit and receiver
• Connect the product into an outlet on a circuit different from that to which the receiver

is connected

• Consult the dealer or an experienced radio/TV technician for help

NOTE
This product contains FCC ID 2AEJD-103902-DT50RF.

2.5.3. United States - AREMA
The product has been tested according to AREMA Part 11.5.1 environmental class B and
AREMA Part 11.5.2 exposure class External.

2.5.4. Canada - IC
This product complies with Industry Canada’s license-exempt RSSs. Operation is subject to
the following two conditions:

• This product may not cause interference.
• This product must accept any interference, including interference that may cause

undesired operation of the product.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:

• l’appareil ne doit pas produire de brouillage.
• l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le

brouillage est susceptible d’en compromettre le fonctionnement.

NOTE
This product contains the IC Certification number 9301A-103902DT50.

10

Ibex-RT-370 Series

Summary of Contents for 3623-077001

Page 1: ...www westermo com Ibex RT 370 Series WLAN 802 11 Access Point with Optical Ethernet ...

Page 2: ...Product Description 12 3 1 Product Description 12 3 2 Available models 13 3 3 Hardware Overview 13 3 3 1 Frontside Overview 13 3 3 2 Front Side Label 13 3 3 3 Rear Side Label 14 3 3 4 Interface Ports View 14 3 4 Connector Information 15 3 4 1 Power Input Connection 15 3 4 2 1000BASE FX Port 15 3 4 3 Ethernet Ports 16 3 4 4 Antenna Ports 16 3 5 LED Indicators 17 3 6 Dimensions 17 4 Installation 19 ...

Page 3: ...7 Revision Notes 31 Ibex RT 370 Series 3 ...

Page 4: ...www westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This p...

Page 5: ...zardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No person...

Page 6: ...g conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not open an energised product Hazardous voltage may occur when connected to a power supply WARNING PROTECTIVE FUSE ...

Page 7: ...temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This product complies with Touch Temperature Limits throughout its operational temperature range CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order t...

Page 8: ...hould not be kept unpowered for more than 30 days 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring the product is disposed of correctly you will help to reduce hazardous substances and prevent potenti...

Page 9: ...ncy devices Safety EN IEC 62368 1 Safety Requirements for audio video information and communication technology equipment EN 45545 2 Fire protection on railway vehicles NFPA 130 Fire protection for fixed guideway transit and passenger rail system 2 5 2 United States FCC The enclosed product complies with Part 15 of the FCC Rules Operation is subject to the following two conditions i this product ma...

Page 10: ...The product has been tested according to AREMA Part 11 5 1 environmental class B and AREMA Part 11 5 2 exposure class External 2 5 4 Canada IC This product complies with Industry Canada s license exempt RSSs Operation is subject to the following two conditions This product may not cause interference This product must accept any interference including interference that may cause undesired operation...

Page 11: ... is in compliance with applicable EU directives and UK legislations The full declaration of conformity and other detailed information is available at www westermo com support product support Figure 2 The European Conformity and the UK Conformity Assessment markings Ibex RT 370 Series 11 ...

Page 12: ... in local LED status indicators and through SNMP WebGUI The Ibex RT 370 access point is designed to withstand tough environmental conditions and can be remotely managed using web browser or SNMP management tools Integrating hardware software and network design support tools this router platform offers advanced capabilities the lowest total cost of ownership and will create the most reliable and re...

Page 13: ...els 3 3 Hardware Overview 3 3 1 Frontside Overview DC OPR ERR X1 X2 2 3 1 No Description 1 LED indicators 2 Front side label 3 Warning symbol for surface temperatures above 60 C Table 3 Location of interface ports and LED indicators 3 3 2 Front Side Label Ibex RT xxx xx EU Power 24VDC 0 6A 3623 075001 00001089 2012 3 2 1 4 Ibex RT 370 Series 13 ...

Page 14: ...turing Year WW Manufacturing Week Table 4 Front side label 3 3 3 Rear Side Label Type Ibex RT xxx xx EU IP66 Art No xxx xxxxxx NPN xxxxxx Max current 0 6A Power 24VDC 30 Country of origin Switzerland FCC IC e label http ip address Default IP 192 168 1 20 Westermo Neratec AG Postfach 83 CH 8608 Bubikon Figure 4 Rear side label content 3 3 4 Interface Ports View ETH2 A1 A2 A3 A4 AC ETH1 4 1 5 2 3 No...

Page 15: ...ports 1000 Mbit s operation Marking Position Direction Description X1 1 Out TX 2 In RX Table 7 ODC 2 male FO connector NOTICE The optical fast Ethernet interfaces of this device uses a class 1 laser product It complies with EN 60825 1 and FDA 21 CFR 1040 10 and 1040 11 The laser is eyesafe under all operating conditions NOTE If the optical Ethernet ports are not used the protective dust cap which ...

Page 16: ...sing Shield Chassis of product ground Table 8 M12 X coded 8 pin female Ethernet connector according to IEC 61076 2 109 NOTE If the Ethernet function is not used the protective dust cap which is part of the delivery must be closed to protect the interface from water or dust ingress 3 4 4 Antenna Ports The antenna connectors are identified on the product with A1 to A4 A1 to A3 are used for WLAN comm...

Page 17: ...onnectors cables and terminations must be used 3 5 LED Indicators AC OPR ERR X1 X2 Figure 5 LED indicators LED Description AC Power status OPR Operation status ERR Error status X1 Ethernet status for X1 port X2 Ethernet status for X2 port Table 9 LED indicators NOTE Refer to management guide for detailed LED status indication 3 6 Dimensions Dimensions are stated in mm and are regardless variants I...

Page 18: ...180 7 7 AC ERR X1 X2 OPR 37 62 5 22 7 31 3 33 3 111 4 22 24 5 24 5 60 5 87 Figure 6 Dimensional drawing 18 Ibex RT 370 Series ...

Page 19: ... to ensure proper heat dissipation NOTE For outdoor installation consider additional protection against sun radiation dust and dirt to optimize ambient temperature range NOTE Unused connectors must be covered by a protective cap delivered with the product tightened to the specified torque in order to fulfill the specified ingress protection code 4 2 Factory Reset To reset the product into factory ...

Page 20: ...on against lightning both earth contacts must be connected to a solid ground The grounding must be done always as a first step before connecting any other external interfaces An M5 grounding screw at the housing is used for the protective bonding conductor A short wire with a cross section of at least 4 mm2 shall be used The grounding wire is set below the rip lock washer The nut is fixed for good...

Page 21: ... ambient temperature is within the specified temperature range e g by avoiding obstruction of the airflow around the product It is recommended to install the product in areas where the natural convection airflow is not blocked and that there is enough spacing around the product Figure 8 Installation with reduced natural convection airflow Figure 9 Installation with natural convection airflow When ...

Page 22: ...nal parameters like RF output power amount of traffic NOTICE This product has integrated temperature sensors for monitoring the internal device temperatures If temperature limits are exceeded alarms are sent through the SW interface NOTICE The operating conditions shall be ensured so that the normal operation does not cause temperature alarms Improve installation conditions or RF parameters in cas...

Page 23: ...Repair i e time for replacement of product is 10 minutes CAUTION HOT SURFACE Be aware that the surface of this product may become hot When it is operated at high temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This product complies with Touch Temperature Limits throughout its operational temperature range Ibex RT 3...

Page 24: ...urrent Redundant power input No Conductor cross section flexible 0 5 to 2 5 mm2 AWG 20 to 13 Cable temperature rating 40 to 70 C Shielded cable Not required aRecommended external supply current capability for proper startup Ethernet FO Connector ODC 2 male Wave length 1310 nm Data rate 1000 Mbit Transmit power 11 to 4 dBm Receiver sensitivity 18 dBm or better Receiver saturationa 3 dBm aOptical at...

Page 25: ...e that the far end side of the Ethernet cable shield itself is connected to protective earth Antenna WLAN A1 to A4 Connector N female Direction Transmit A1 and A2 and receive A1 to A3 Cabling 50 Ohm coaxial cable and WLAN antenna required Conductive chassis Yes WLAN interface 2x2 MIMO 802 11n Access Point A1 and A2 1x802 11abgn Monitoring A3 WLAN frequency bands 2 400 to 2 4835 GHz 5 150 to 5 350 ...

Page 26: ...t must be terminated with 50 Ohm terminations NOTICE To avoid damages on the antenna interfaces ensure that the far end side of the antenna cable and or the antenna itself is connected to protective earth 26 Ibex RT 370 Series ...

Page 27: ...EN 61000 4 8 Enclosure 300 A m continues DC 16 7 Hz 50 Hz 60 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 AM 1 kHz at 80 MHz to 2 GHz 5 V m 80 AM 1 kHz at 2 to 2 7 GHz 3 V m 80 AM 1 kHz at 2 7 to 6 MHz Conducted RF immunity EN 61000 4 6 AC power port 10 V 80 AM 1 kHz from 0 15 to 80 MHz Ethernet ports Antenna ports Radiated RF emissi...

Page 28: ...o 2000 Hz 3 x 4 h Shockb EN 60068 2 27 Operational 20 m s2 11 ms 3 x 6 shocks half sine MIL STD 810 M516 7 10 g 11 ms 3 x 6 shocks saw tooth Weight 1750 gr Degree of protection EN 60529 Enclosure IP66c Cooling Convection Pollution degree EN 62368 1 PD2 Conformal coating type IPC A 610 Electronic modules AR Acrylic aRefer to Safety and Regulations chapter regarding touch temperature bThe power and ...

Page 29: ...opean Standard ERR Error ESD Electro Static Discharge ETSI European Telecommunications Standards Institute FCC Federal Communication Commission FLOSS Free Libre Open Source Software FO Fiber Optic IEC International Engineering Consortium IC Industry Canada ID Identification I O Input Output IP Ingress Protection ISO International Standardization Organisation LAN Local Area Network LED Light Emitti...

Page 30: ...erial Number SNMP Simple Network Management Protocol WebGUI Web Graphical User Interface WeConfig Westermo Configuration Tool WEEE Waste Electrical and Electronics Equipment WLAN Wireless Local Area Network Table 12 Abbreviations and terms 30 Ibex RT 370 Series ...

Page 31: ...er 3 5 Led Indicators illustration added 4 2 Factory Reset moved from old chapter 3 6 4 5 Cooling illustrations updated Rev F 2021 06 2 5 5 Europe Simplified Declaration of Conformity updated text and figure Rev E 2020 11 Updated with blue illustrations Rev D 2020 09 Updated for new user manual template Rev C 2017 08 Product label example updated for RED directive Rev B 2017 03 Regulation part upd...

Page 32: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6623 2280 REV G 2021 10 Westermo Network Technologies AB Sweden ...

Reviews: