Section 311-610-20B
030-101522 Rev. C
19
0509IBRC
Figure 24. Test Mode Provisioning Menu Screen
Westell B90-311610
CLEI: T1L8AC0AAA
TEST MODE PROVISIONING MENU
Option
Current
New
>
Test Pattern:
1:7
1:1
Framing for Pattern
SF
Test Pattern to CPE
ENABLED
Test Pattern to NET:
DISABLED
User Pattern:
10111110
SELECTIONS
S) Save
D) Set to default settings
Use <tab> to select option, <space> to change, or Esc to return to main menu
Figure 25. NOTE PAD Screen
Westell B90-311610
CLEI: T1L8AC0AAA
NOTE PAD
No.
Date
Time
Notes
1
06/05/03
14:51:17
NIU PUT INTO SERVICE
2
06/05/03
14:51:53
PM DATA CLEARED
SELECTIONS
A) Add record
D) Delete record
E) Edit record
Enter selection or ESC to go back to previous menu
Field
Parameter
Default
TEST PATTERN
1:1
1:7
ALL ONES
USER (4-16 BITS)
FRAMING FOR PATTERN
UNFRAMED
SF
ESF
TEST PATTERN TO CPE
ENABLED
DISABLED
TEST PATTERN TO NET
ENABLED
DISABLED
Table 7. 3116-10 Test Mode Parameters
9.2.7.1
Saving The Changed Options
After configuring the options, press <S> to save the new set-
tings.
Note:
If you enter <Esc> without saving, the system will give
a message asking if you want to save the new settings.
- WARNING -
If the craft terminal is disconnected without saving the changes, the
changes will be lost (unit does not save changes automatically).
9.2.7.2
The test mode is activated while in the STATUS screen
by using the <Ctrl><T> keys simultaneously. Additional ap-
plications of <Ctrl><T> will toggle the state of the test mode.
9.2.8
NOTE PAD Screen
The Note Pad screen provides a means for Craft personnel to log
notes about the circuit. See Figure 25. Each entry is date and
time stamped for future reference. Up to 15 notes can be en-
tered, with each note limited to 50 characters. Add, delete, and
edit selections allow the user to manage entries.
9.2.9
ALARM THRESHOLDS Screen
The ALARM THRESHOLDS screen allows the user to set vari-
ous performance monitoring thresholds for the different
parameters, illustrated above in Figure 26. An event will be re-
corded in the Event/Alarm log when any parameter threshold is
exceeded. A threshold setting of 0" will disable it.
9.2.10
REPORTS screen
The CRAFT port provides a means for downloading various re-
ports to a PC running HyperTerminal software. The menu
option for performing this function will be labeled RE-
PORTS", and will appear as part of the MAIN menu. Once