Figure 26. ALARM THRESHOLDS Screen
Westell B90-311610
CLEI: T1L8AC0AAA
ALARM THRESHOLDS
PARAMETER
15-MINUTE
1−DAY
>
>
CV-L
387
0
3865
ES-L
25
250
SES-L
4
40
CVP-P
382
3820
ESP-P
25
250
SESP-P
4
40
UASP-P
10
10
SELECTIONS
S) SAVE
D) SET DEFAULT THRESHOLDS
X) DISABLE All THRESHOLDS
NOTE: Setting a threshold to a value of 0 will disable it
Enter selection or ESC to go back to previous menu
Figure 27. REPORTS Screen
Westell B90-311610
CLEI: T1L8AC0AAA
REPORTS MENU
1)
Information Report
2)
Event Log Report
3)
Current PM Report
4)
Full PM Report
?)
Help
Details on saving a report to file are available
on the help screen by pressing the ?" key.
Enter selection or ESC to go back to previous menu
selected, the REPORTS" screen, Figure 27, will allow the user
to select from one of four options, labeled as follows:
1.
Information Report - Provides all provisioning (including
Alarm Threshold) information about the unit.
2.
Event Log Report - Provides all provisioning information
and a complete listing of all stored Event/Alarm Log
events.
3.
Current PM Report - Provides all provisioning information,
and detailed PM information for the current 15-minute,
current hour and current day.
4.
Full PM Report - Provides all provisioning information, and
a complete listing of all PM information stored in the unit.
Reports Screen Download Procedure
1.
Select Transfer," Capture Text" from the Hyper Terminal
drop down menu.
2.
Enter a file name then select Start."
3.
Select a report number 1," 2," 3," or 4" to capture data
from the SEND DATA TO LOG FILE" menu.
4.
After download is complete, select Transfer," Capture
Text," and Stop" from HyperTerminal.
9.3
Remote Provisioning and Query via TL1
The NIU is capable of being provisioned and queried via TL1
commands. These TL1 commands and responses are trans-
ported via the Facility Data Link and do not require that the unit