background image

 

PS71090

E

 Product Manual

  

 

 

October 2019, Rev A 

 

 

 

 

 WESTELL.COM 

 

©2019 Westell 
Technologies  

 

 

September 2019; 

Doc No. CS14702802UM 

rD 

 

1.877.844.4274  

  

Page 38 of 61 

 

 

 

  

4.

 

When the Signal Booster is properly set up and ready to have power applied, 
plug the other end into the 110VAC outlet.   

   

  

  

 

Figure 5-9: Power Cable Connected to Signal Booster 

 

 

 

 

  

 

 

5.9 Connecting the Battery Back-up Cable  

 

 

 

Use the provided DC Power Cable to connect the PS71090E Public Safety Signal Booster to a 24-

 

30VDC Battery Back-up / power source.  (Pin A, White = positive, Pin B, Black = Negative) 

 

Figure 5-10: Battery Cable Connected to Signal Booster 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PS71090E

Page 1: ...STELL COM 2019 Westell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 1 of 61 PS71090E Product Manual October 2019 Rev A 5689 PS71090E 2W Public Safety Signal Booster Users Gui...

Page 2: ...om the products described herein or the infringement by such products of any property rights of any persons Use or application of such information or statements is at the users sole risk without any l...

Page 3: ...GENERAL INFORMATION 11 1 1 Document Purpose and Intended Users 11 1 2 Application 11 1 2 1 Product Registration Information 11 1 3 Safety Guidelines 12 1 3 1 Important Safety Information 13 1 4 FCC P...

Page 4: ...lines 28 CAUTION 29 5 2 Donor Antenna Installation Guidelines 29 5 3 Indoor Antenna Installation Guidelines 29 5 4 Mounting the Signal Booster 30 5 5 Verifying the Physical System Setup 31 5 6 Control...

Page 5: ...NYMS AND ABBREVIATIONS 60 TABLE OF FIGURES Figure 1 1 Product Registration 11 Figure 4 1 External Product Configuration 24 Figure 5 1 Repeater Mounting Bracket Mounted on Repeater Rear 27 Figure 5 2A...

Page 6: ...ure 6 6 Control Mode 40 Figure 7 1 Firmware Upgrade Progress Window showing File Open tab 45 Figure 7 2 Firmware Version Check 45 Figure 7 3 Firmware Update Status 46 Figure 7 4 IP Settings 46 Figure...

Page 7: ...ms and Abbreviations Copyright and Trademark Acknowledgements Purpose This manual contains information and procedures for the operation of the Westell PS71090E Public Safety Signal Booster Changes tha...

Page 8: ...ifications Also provides information about GUI items alarm status and alarm relay Chapter 4 Product Appearance Provides physical specifications photographs and information about the external and inter...

Page 9: ...voided may result in personal injury or serious equipment damage CAUTION Description of a conditions or practice that could cause damage to equipment or property Communicates information that is cruci...

Page 10: ...ese precautions or specific warnings elsewhere in the manual violates the safety standards of design manufacture and intended use of equipment Westell assumes no liability for the customer s or user s...

Page 11: ...gnal Booster Follow the instructions in this guide to minimize risks associated with modifying a live system and preclude service interruptions This document assumes the technician or engineer underst...

Page 12: ...ure and intended use of equipment Westell assumes no liability for the customer s failure to comply with these requirements Grounding This Signal Booster is designed to operate at 110VAC 1 02A maximum...

Page 13: ...tances Indoor antennas must be placed so that under normal conditions personnel cannot come within 30 cm 12 in of any inside antenna Adhering to this minimum separation will ensure that the employee o...

Page 14: ...must have an FCC license or express consent of an FCC Licensee to operate this device You must register class B signal boosters as defined in 47 CFR 90 219 online at www fcc gov signal boosters regist...

Page 15: ...stell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 15 of 61 Right Side View 1 5 FCC Contact Information Federal Communications Commission 445 12th Street SW Washington DC 205...

Page 16: ...arious other types may be used depending on the coverage application The Signal Booster amplifies both the uplink mobile to base and downlink base to mobile signals thus facilitating communications to...

Page 17: ...uded Accessories Table 2 1 contains the items that are shipped with the PS71090E Public Safety Signal Booster Table 2 1 Included Accessories Quantity Description 1 AC Power 14AWG Cable 5 feet 10 inche...

Page 18: ...4702802UM rD 1 877 844 4274 Page 18 of 61 2 4 Optional Accessories A complete line of accessories is available from Westell Check with your Westell distributor for any additional items needed Some pro...

Page 19: ...oduct Manual October 2019 Rev A WESTELL COM 2019 Westell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 19 of 61 3 Product Specification 3 1 RF Specifications Table 3 1 RF Spec...

Page 20: ...4MHz Sub Band1 851 861MHz Sub Band2 851 869MHz Sub Band3 RF technology UL DL P25 LTE LTE FirstNet Output Power DL 700MHz 800MHz 30dBm per Band Dual Band Operate 700MHz Only 33dBm Sing Band Operate per...

Page 21: ...0W Typical 3 3 Mechanical Specification Table 3 3 Mechanical Specifications Parameter Specification Note Size 15 7 x 18 9 x 5 0 in L x H x D Connectors Donor Coverage Antenna Ports 4 3 10 f Matting Ma...

Page 22: ...44 4274 Page 22 of 61 Finish Red color Paint RAL3001 Signal RED 3 4 Environmental Specification Table 3 4 Environmental Specifications Parameter Specification Note Operating Temperature 30 C 50 C ambi...

Page 23: ...tery Charger Fail Relay Status Donor ANT VSWR Malfunction Service ANT VSWR Manual Amp Off Battery Capacity Low UL HPA Fail DL HPA Fail UL Shutdown Displays alarm status UL DL Shutdown Setting 23dBm to...

Page 24: ...out the GUI 3 6 Alarm Status Table 3 6 Alarm Status Alarm GUI Outside LED of the Repeater AC Power Battery Cap Low Battery Charger RF Emitter Donor ANT Disconnect System Comp PLL LD O Green x x x x Re...

Page 25: ...arm Relay Alarm Alarm of the Relay Relay 1 1 2 3 Relay 2 4 5 6 Relay 3 7 8 9 Relay 4 10 11 12 Relay 5 13 14 15 Relay 6 16 17 18 AC Fail O X X X X X Battery Cap Low X O X X X X Battery Charger Fail X X...

Page 26: ...ity at 70 reduction of operating capacity Alarm3 7 8 9 BATTERY CHARGER FAIL Alarm4 10 11 12 RF EMITTER FAIL Alarm5 13 14 15 DONOR ANT Malfunction DISCONNECTION Alarm6 16 17 18 SYSTEM COMPONENT FAIL NO...

Page 27: ...nual October 2019 Rev A WESTELL COM 2019 Westell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 27 of 61 4 Product Appearance 4 1 External Configuration Figure 4 1 External Pro...

Page 28: ...t disassemble the Signal Booster DANGER Refer to the 1 3 Safety Guidelines section for proper antenna selection and installation To avoid serious injury death and or damage to the Signal Booster do no...

Page 29: ...approach helps avoid interference and feedback to and from the service antennas Normally mounting the donor antenna higher will allow a less obstructed path to the donor site However in high traffic m...

Page 30: ...r antenna in most cases can be expected to penetrate approximately two standard sheet rock walls to reach users If the signal must travel through more than two walls or if the walls are made of materi...

Page 31: ...pass heading Typically the directional antenna would be aimed at the same site that your handset uses but that may not always be the case If cables and alignment are acceptable and a problem persists...

Page 32: ...7 Connecting to the Alarm Relay Panel Use the provided Alarm Relay Serial Cable to connect the PS71090E Public Safety Signal Booster to the alarm relay panel If the provided cable is not long enough f...

Page 33: ...Page 33 of 61 Figure 5 3 Stripped Alarm Wire 3 Remove the protective cover on the Alarm Relay 9 position D Sub connector Figure 5 4 Alarm Relay 18 wire Gland Connector M6110 4 Connect the M6110 Gland...

Page 34: ...71090E Product Manual October 2019 Rev A WESTELL COM 2019 Westell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 34 of 61 Figure 5 5 Alarm Relay Cable Connected to Signal Boost...

Page 35: ...for connection information Table 5 1 Alarm Relay Connections Alarm 18Pin Description Alarm Information Relay Status NC NO CC Alarm1 1 2 3 AC POWER LOSS OF AC POWER Normal NC CC Alarm NO CC Alarm2 4 5...

Page 36: ...le to connect the PS71090E Public Safety Signal Booster to an AC power source 1 Remove the M6110 Gland Connector Molded from the AC 110V power connector on the Signal Booster Figure 5 6 Figure 5 6 Rem...

Page 37: ...9 Rev A WESTELL COM 2019 Westell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 37 of 61 Figure 5 7 Connection AC Power Cable 3 Screw the connector on securely Figure 5 8 Power...

Page 38: ...p and ready to have power applied plug the other end into the 110VAC outlet Figure 5 9 Power Cable Connected to Signal Booster 5 9 Connecting the Battery Back up Cable Use the provided DC Power Cable...

Page 39: ...provided PS71090E PS SMR 700 800 software through a LAN connection The Signal Booster ships with the IP address 192 168 1 150 on the GUI port To connect directly to the Signal Booster from a laptop o...

Page 40: ...s any number from 2 to 254 inclusive other than 150 e g Set Computer IP to 192 168 1 2 2 Ensure that the subnet mask is set to 255 255 255 0 NOTE Refer questions about these settings to your IT depart...

Page 41: ...lick Next and Finish Figure 6 4 PS71090E PS51080E GUI Log In Item Description 1 IP Address Field editable when Connect button is displayed 2 Connect Disconnect toggle button 3 TX RX LED indicates the...

Page 42: ...Connect button The button label changes to Disconnect 6 2 Status Clicking the Status button in the menu on the left of the page changes the button text to and displays the Status Mode page described i...

Page 43: ...ure of the Signal Booster Item Section 2 Site Location Company Company information display Address Address information display City City information display State State information display Contact Con...

Page 44: ...requency Displays sub band 1 downlink Stop frequency 800MHz Band Allows sub band 1 to be set to Select Sub band 2 Uplink Start Frequency Displays sub band 2 uplink Start frequency Stop Frequency Displ...

Page 45: ...range 700 MHz Output dBm Displays Output value by 700 MHz Band Gain dB 800 MHz Displays Downlink gain in the 800 MHz range 800 MHz Output dBm Displays Output value by 800 MHz Band AGC Level dBm Displa...

Page 46: ...80 dB Isolation Max Gain The isolation checked can be display with Isolation maximum Gain Item Section 7 Uplink Squelch Mute Level Uplink muting threshold level display Range 105 80dBm ON OFF Squelch...

Page 47: ...10 Alarm Monitoring Not User Configurable Alarm Test and Alarm Informational Only GREEN Normal RED Alarm PLL LD Local PLL Lock Detect Fail Isolation Fail After Isolation Check lack of Isolation and r...

Page 48: ...k HPA Battery Capacity Low Low Battery capacity at 70 reduction UL Shutdown PA protection Uplink HPA off Battery Charger Fail Battery Disconnection or Battery No charging status DL HPA Fail Downlink H...

Page 49: ...844 4274 Page 49 of 61 and displays the Control Mode page described in this section Item Section 1 700MHz Band Selection Uplink Displays 700MHz uplink Start frequency Displays 700MHz uplink Stop freq...

Page 50: ...ys 800MHz downlink Stop frequency Bandwidth 3MHz 10MHz 18MHz Band ON Band OFF Item Section 3 Shutdown Allows the shut down level to be set Downlink Shutdown Allows the downlink shutdown level to be se...

Page 51: ...ion Item Section 6 Downlink Gain dB 700 MHz Displays downlink gain in the 700 MHz range User Atten 700 MHz Setting User attenuation value controlled by downlink in the 700 MHz band AGC Atten dB 700 MH...

Page 52: ...lled by AGC in the 700 MHz band Gain dB 800 MHz Displays Uplink gain in the 800 MHz range User Atten 800 MHz Setting User attenuation value controlled by Uplink in the 800 MHz band AGC Atten dB 800 MH...

Page 53: ...F Mute Check ON OFF Item Section 10 Buzzer Enable Disable Buzzer ON OFF Buzzer ON OFF any alarm raised Buzzer On Off Period 1sec Buzzer On 9sec Buzzer Off Every 10sec Item Section 11 Alarm Setting Ala...

Page 54: ...ervice Antenna VSWR Check Fail Manual AMP Off HPA Off Downlink or Uplink HPA Battery Capacity Low Low Battery capacity at 70 reduction Alarm Test On Off UL Shutdown PA protection Uplink HPA off Batter...

Page 55: ...ewer version of system software as required 1 Click the Control button to display the Control page 2 Click in the menu located on the left side of the Control page The System Upgrade progress window F...

Page 56: ...M 2019 Westell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 56 of 61 6 Click in the System file upload dialog window system upgrade begins as indicated by the progress bar in...

Page 57: ...anual October 2019 Rev A WESTELL COM 2019 Westell Technologies September 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 57 of 61 7 2 IP Change Figure 7 4 IP Settings 1 With Control ON the IP Change b...

Page 58: ...ow 1 Successful completion of IP Read Status LED turns green and change icon is activated 2 When the IP Change Window is opened the current status is displayed Figure 7 10 a Static IP can be set See 7...

Page 59: ...eptember 2019 Doc No CS14702802UM rD 1 877 844 4274 Page 59 of 61 7 2 3 DHCP IP Setting Figure 7 7 DHCP IP Setting 1 After DHCP select please click the YES button Appendix A Important Product Informat...

Page 60: ...Abbreviations Acronym Abbreviation Definition AC Alternating Current AGC Automatic Gain Control COM Communications dB Decibels dBc Decibels relative to the carrier dBi Decibels relative to isotropic d...

Page 61: ...4702802UM rD 1 877 844 4274 Page 61 of 61 NMS Network Management System OSC Oscillator PLL LD Phase locked loop with lock detection RF Radio Frequency RS 232C Serial Communication Standard UL Uplink U...

Reviews: