background image

     PS71090-P8 Product Manual

  

March 2018, Rev A 

 

WESTELL.COM 

 

©2017 Westell Technologies 

 

March  2018; Doc No. CS14000802UM rA 

1.877.844.4274 

 

Page  1 of 52 

5689 

 

 

 

 

PS71090-P8 2W Public Safety Signal 

Booster 

Users Guide 

 

 

 

 

 

 

 

 

 

 

 

P

RO
D

U

C

T MAN

U

AL
 

Summary of Contents for PS71090-P8

Page 1: ...8 Product Manual March 2018 Rev A WESTELL COM 2017 Westell Technologies March 2018 Doc No CS14000802UM rA 1 877 844 4274 Page 1 of 52 5689 PS71090 P8 2W Public Safety Signal Booster Users Guide PRODUC...

Page 2: ...sults that may be obtained from the products described herein or the infringement by such products of any property rights of any persons Use or application of such information or statements is at the...

Page 3: ...0 Technical Support 10 Acronyms and Abbreviations 10 Copyright and Trademark Acknowledgements 10 1 GENERAL INFORMATION 11 1 1 Document Purpose and Intended Users 11 1 2 Application 11 1 2 1 Product Re...

Page 4: ...arm Status 21 3 7 Alarm Relay 23 NOTE 23 4 PRODUCT APPEARANCE 24 4 1 External Configuration 24 5 INSTALLATION GUIDELINES 25 5 1 Important Installation Guidelines 25 CAUTION 26 5 2 Donor Antenna Instal...

Page 5: ...7 2 1 IP Change Window 48 7 2 2 Static IP Setting 49 7 2 3 DHCP IP Setting 49 APPENDIX A IMPORTANT PRODUCT INFORMATION 50 A 1 Registration Number 50 A 2 UL 50 APPENDIX B ACRONYMS AND ABBREVIATIONS 51...

Page 6: ...up 34 Figure 6 2 DestinationDirectory 35 Figure 6 3 Software Installation 35 Figure 6 4 PS71090 P8 GUI Log In 36 Figure 6 5 StatusMode 37 Figure 6 6 Control Mode 41 Figure 7 1 System Firmware Upgrade...

Page 7: ...t Conventions Safety Notices Technical Support Acronyms and Abbreviations Copyright and Trademark Acknowledgements Purpose Thismanual containsinformationandproceduresforthe operationof the Westell PS7...

Page 8: ...ations AlsoprovidesinformationaboutGUI items alarmstatus and alarm relay Chapter 4 Product Appearance Provides physical specifications photographs and information about the external and internal Signa...

Page 9: ...topreventinglossof dataor damage to hardware or software andactionsthatcouldresultinequipmentfailure IMPORTANT Additional importantinformationthatthe usermustbe aware of but isnot relatedtoa hazard N...

Page 10: ...fire do not operate this product in the presence of flammable gases or fumes Lightningdanger Do notinstall ormake adjustmentstothisunitduringanelectrical storm WARNING ChangesandModificationsnotexpre...

Page 11: ...ciatedwithmodifyingalive systemandpreclude service interruptions This documentassumesthe technicianorengineerunderstandsthe basicprinciplesandfunctionality involvedwith anRFSignal Boosterandin buildin...

Page 12: ...mes no liabilityforthe customer sfailure tocomplywiththese requirements Grounding ThisSignal Boosterisdesignedtooperate at110VAC 1 0A maximumcurrentandmust alwaysbe operatedwiththe groundwire properly...

Page 13: ...neral population uncontrolled exposure Outdoor antenna must be positioned so that under normal conditions personnel cannot approach closerthan 120 cm 4 ft A directional antennahavingamaximumgainof 3 7...

Page 14: ...ies March 2018 Doc No CS14000802UM rA 1 877 844 4274 Page 14 of 52 FCC Label Placement on the PS71090 P8 Right Side View 1 5 FCC Contact Information Federal CommunicationsCommission 445 12th StreetSW...

Page 15: ...endingonthe coverage application The Signal Boosteramplifiesboththe uplink mobile tobase anddownlink base to mobile signals thusfacilitatingcommunicationstoandfromthe intendedwirelessinfrastructure Wi...

Page 16: ...Table 2 1 containsthe itemsthatare shippedwiththe PS71090 P8PublicSafety Signal Booster Table 2 1 Included Accessories Quantity Description 1 AC PowerCable 5feet10 inches 1 DC PowerCable 5 feet10 inch...

Page 17: ...N 13 dB ClearLink PT13 340 2 7K 4310 ClearLink PT13 340 2 7K N 15 dB ClearLink PT15 340 2 7K 4310 ClearLink PT15 340 2 7K N 20 dB ClearLink PT20 340 2 7K 4310 ClearLink PT20 340 2 7K N 30 dB ClearLink...

Page 18: ...2 806 824 MHz Sub Band3 IndependentlyControlled via the GUI DL 851 854 MHz Sub Band1 851 861 MHz Sub Band2 851 869 MHz Sub Band3 Linear Output Power UL DL 33dBm Gain UL DL 90dB 1 0dB Gain AdjustmentRa...

Page 19: ...24 VDC Input 65W Max 0 9 Amps Max 2 7 Amps Max 3 3 Mechanical Specification Table 3 3 Mechanical Specifications Parameter Specification Note Size 17 7 x 14 1 x 4 7 in L x H x D Connectors Donor Covera...

Page 20: ...Bm to 38dBm Readsand displaysthe UL DL outputpower AlarmReadoutDisplays PLL LD Lock Detector Isolation UL DL shutdown DCFail Relay Status UL DL VSWR Manual Amp AntennaFailure Power UL HPA Fail DL HPA...

Page 21: ...linking Relay Status RED PLL LD RED DL UL HPA RED Manual Amp RED Rest GREEN Isolation Minimum isolation betw een Donor server Antenna Gain 15dB Alarm1 Alarm2 X O Solid Blinking OFF Relay Status RED Is...

Page 22: ...R RED Rest GREEN Disable Alarm Normal Solid OFF OFF Relay Status GREEN UL VSWR RED Rest GREEN Manual Amp Manual Amp Alarm2 X O Solid OFF Solid Relay Status RED Manual Amp RED DL UL HPA Fail RED Rest G...

Page 23: ...Solid Relay Status RED Manual Amp RED UL HPA FAIL RED Rest GREEN 3 7 Alarm Relay Table 3 7 Alarm Relay Shutdown Signal Relay Status Note Normally Open NO pin 2 CC pin 3 PIN 1 NC PIN 2 NO PIN 3 CC PIN...

Page 24: ...WESTELL COM 2017 Westell Technologies March 2018 Doc No CS14000802UM rA 1 877 844 4274 Page 24 of 52 4 ProductAppearance 4 1 External Configuration Figure 4 1 External Product Configuration AC PWR BAT...

Page 25: ...fety Guidelines section for proper antenna selection and installation To avoid serious injury death and or damage to the Signal Booster donotinstall donororserverantennasnearoverheadpowerlinesor high...

Page 26: ...ter adjacent channel interference When possible shieldthe rear of a donor antenna by locating it so that any HVAC units and orpenthouse structuresare behindthe antenna relativetothe donorcell siteloca...

Page 27: ...as a template mark the four 4 locations for the wall anchoring system screws 2 Move the PS71090 P8 unitanddrill the mountingholesatthe marksinthe wall Install a wall anchorin eachof the four 4 drilled...

Page 28: ...ectrumanalyzer to examine the signal environment in which the unit is operating The existence of strong adjacent channel signals within the frequency band s can cause the AGC to reduce the amplifier s...

Page 29: ...0 P8 PublicSafety Signal Boosterto the alarm relaypanel If the providedcable isnotlongenoughforyoursystem youwill needtobuild one 1 Stripthe outerserialcable insulationbacktoexposethe innerconductors...

Page 30: ...Connect the stripped end of the serial cable to the alarm relay panel Refer to Table 5 1 for connection information Table 5 1 Alarm Relay Connections Pin Number Contact Type Conductor Color supplied C...

Page 31: ...le toconnectthe PS71090 P8 PublicSafety Signal BoostertoanAC powersource 1 Remove the cap from the AC 110V power connector on the Signal Booster Figure 5 6 Figure 5 6 Remove the Power Connector Cap 2...

Page 32: ...CS14000802UM rA 1 877 844 4274 Page 32 of 52 3 Screw the connector on securely Figure 5 8 Power Cable Connected to Signal Booster 4 When the Signal Booster is properly set up and ready to have power a...

Page 33: ...c No CS14000802UM rA 1 877 844 4274 Page 33 of 52 5 9 Connecting the Battery Back up Cable Use the providedDCPowerCable toconnectthe PS71090 P8 PublicSafetySignal Boostertoa 24 30VDC Battery Back up p...

Page 34: ...tertoenable aconnectiontoa hostthat has a static IP Open Control Panel All Control Panel Items Network Connections Choose appropriate Local area connection Figure 6 1 Network Connection Set up 1 Selec...

Page 35: ...t Manual March 2018 Rev A WESTELL COM 2017 Westell Technologies March 2018 Doc No CS14000802UM rA 1 877 844 4274 Page 35 of 52 Figure 6 2 Destination Directory Figure 6 3 Software Installation 5 Click...

Page 36: ...communication with the Signal Booster and GUI 4 Button to change PORT settings related to IP connection 6 Verify that the IP address in the upper left of the page is correct 192 168 1 150 if it is not...

Page 37: ...ture Displays the Signal Booster s manufacturer Signal Booster Type Displays Signal Booster Model Number Signal Booster S N Displays Signal Booster Serial Number S W Version Displays firmware version...

Page 38: ...nd 1 downlink Stop frequency 800MHz Band Allows sub band 1 to be set to Select Sub band 2 Uplink Start Frequency Displays sub band 2 uplink Start frequency Stop Frequency Displays sub band 2 uplink St...

Page 39: ...Gain dB Displays status of the uplink gain UL Output dBm Displays uplink output level ALC Level dBm Displays Automatic Gain Control Level HPA Displays Uplink HPA On Off Item Section 6 Isolation Isola...

Page 40: ...GH BATT High Power Alarm DC FAIL BATT AC Power Alarm DL HPA FAIL DL Path HPA Alarm UL HPA FAIL UL Path HPA Alarm Item Section 8 VSWR DL UL Ratio VSWR Ratio Status Display 0 00 to 30 00 Limit VSWR Rati...

Page 41: ...e shut down level to be set Downlink Shutdown Allows the downlink shutdown level to be set to on or off Shutdown Level dBm Allows the maximum shutdown level to be set between 23 and 37 Uplink Shutdown...

Page 42: ...A 1 877 844 4274 Page 42 of 52 Item Section Shutdown Period Allows the shutdown period to be set in minutes and seconds Item Section 3 Location Company Company information display Address Address info...

Page 43: ...s sub band 1 to be set to Select Sub band 2 Uplink Start Frequency Displays sub band 2 uplink Start frequency Stop Frequency Displays sub band 2 uplink Stop frequency Downlink Start Frequency Displays...

Page 44: ...isplays status of the uplink gain Atten dB Sets the attenuation value AGC Atten dB Displays attenuation value controlled by AGC AGC Control Auto Gain Control Function On Off AGC Level dBm Sets the uni...

Page 45: ...check UL VSWR UL Path VSWR check Manual Amp User HPA OFF Alarm BATT FAIL LOW BATT Low Power Alarm BATT FAIL HIGH BATT High Power Alarm DC FAIL BATT AC Power Alarm DL HPA FAIL DL Path HPA Alarm UL HPA...

Page 46: ...emsoftware asrequired 1 Click the Control button to display the Control page 2 Click inthe menulocatedonthe leftside of the Control page The System Upgrade progress window Figure 7 1 displays Figure 7...

Page 47: ...ck dialog window Figure 7 2 The firmware upgrade begins as indicated by the progress bar in the Firmware Version Check window Figure 7 3 Figure 7 3 Firmware Update Status Item Function 1 Stop Button t...

Page 48: ...Figure 7 4 IP Settings 1 With Control ON the IP Change button is activated 7 2 1 IP Change Window Figure 7 5 IP Change Window 1 Successful completion of IP Read Status LED turns green and change icon...

Page 49: ...S14000802UM rA 1 877 844 4274 Page 49 of 52 7 2 2 Static IP Setting Figure 7 6 Static IP Setting 1 Please write the Address netmask broadcast gateway 2 If have all information set please press YES but...

Page 50: ...2018 Rev A WESTELL COM 2017 Westell Technologies March 2018 Doc No CS14000802UM rA 1 877 844 4274 Page 50 of 52 Appendix A ImportantProductInformation A 1 Registration Number FCC NVRPS71090 P8 A 2 UL...

Page 51: ...s dBc Decibelsrelative tothe carrier dBi Decibelsrelative toisotropic dBm The powerratio indecibels dB of the measured powerreferencedtoone milliwatt mW DC DirectCurrent DL Downlink FCC Federal Commun...

Page 52: ...PS71090 P8 Product Manual March 2018 Rev A WESTELL COM 2017 Westell Technologies March 2018 Doc No CS14000802UM rA 1 877 844 4274 Page 52 of 52 Appendix C Downlink Uplink VSWR Alarm Timing Diagram...

Reviews: