West Mountain Radio PWRguard PLUS Operating Manual Download Page 9

9

West Mountain Radio

Operating Manual

FCC INFORMATION

For a Class B digital device or peripheral, the user instructions shall include the 

followling or similar statement, placed in a prominent location in the text of the 

manual:

Note: This equipment has been tested and found to comply with the limits for 

a class B digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection again harmful interference in a 

residential installation. This equipment generates,uses and can radiate radio 

frequency energy, and if not installed and used in accordance with the guaran-

tee that interference will not occur in a particular installation. If this equipment 

does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to 

correct the interference by one or more of the following measures: 

 

•Reorient or relocate the receiving antenna

 

•Increase the separation between the equipment and receiver        

 

•Connect the equipment into an outlet on a circuit different  

 

    

  from that to which the receiver is connected.

 

•Consult the dealer or an experienced radio/TV technician for     

 

  help.

Modifications not expressly approved by the manufacturer could void the user’s 

authority to operated equipment under the FCC Rules

.

PWRguard Plus Warranty

PWRguard Plus

 is warranted against failure due to defects in workmanship or materials for 

one year after the date of purchase from West Mountain Radio. Warranty does not cover 

damage caused by abuse, accident, misuse, improper or abnormal usage, failure to follow 

instructions, improper installation, alteration, lightning, or other incidence of excessive 

voltage or current. If failure occurs within this period, return the 

PWRguard Plus

 or accessory 

to West Mountain Radio at your shipping expense. The device or accessory will be repaired 

or replaced, at our option, without charge, and returned to you at our shipping expense. 

Repaired or replaced items are warranted for the remainder of the original warranty period. 

You will be charged for repair or replacement of the 

PWRguard Plus

 or accessory made after 

the expiration of the warranty period.

West Mountain Radio shall have no liability or responsibility to customer or any other person 

or entity with respect to any liability, loss, or damage caused directly or indirectly by use 

or performance of the products or arising out of any breach of this warranty, including, 

but not limited to, any damages resulting from inconvenience, loss of time, data, property, 

revenue, or profit, or any indirect, special incidental, or consequential damages, even if 

West Mountain Radio has been advised of such damages.

Except as provided herein, West Mountain Radio makes no express warranties and any 

implied warranties, including fitness for a particular purpose, are limited in duration to the 

stated duration provided herein.

                                                    www.westmountainradio.com

                                                         1020 Spring City Drive, Waukesha, WI 53186      

                                                   tel 262-522-6503 fax 262-522-6504

Summary of Contents for PWRguard PLUS

Page 1: ...tainradio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2016 West Mountain Radio All rights reserved All trademarks are the property of their respective owners PWRguard PLUS ...

Page 2: ...d if you do not need an audible alert Modes of Operation Automatic and Manual Automatic Mode Supply Voltage Not In Normal Range When the supply voltage is outside of the normal range the PWRguard PLUS will disconnect the load Upon restoration of normal supply voltage the load will be reconnected automatically Sense Input Triggered When the sense input is activated the PWRguard PLUS will disconnect...

Page 3: ...inal post marked Buzzer 4 When the power supply is switched on the PWRguard Plus unit will become operational and the AUTO RESET and ON LEDs will both glow green If the AUTO RESET LED does not turn on hold the reset button down for 5 seconds until it does If the YELLOW LED Low fault comes on instead of the ON LED it means that your power supply or battery voltage is too low PWRguard Plus requires ...

Page 4: ...0S output terminal and then plug the PWRguard PLUS output into the RIGrunner input terminal This will provide protection for the battery and all the devices that are plugged into the RIGrunner Additionally after loss of AC mains power the PWRguard PLUS will reset the system after the power is restored Integrated Set Up ...

Page 5: ...reset mode the RED LED will turn off when the input voltage returns to less than 15V and the output will turn ON thereby relighting the GREEN LED and re powering the load YELLOW LED Low Fault The YELLOW LED low fault will light whenever the input voltage drops below 11 0V This LED will also briefly light if there are momentary dips below 11 0V This feature assures correct operation during turn on ...

Page 6: ...low fault will light whenever the input voltage drops below 11 0V This LED will also light briefly if there are momentary dips below 11 0V This feature assures correct operation during turn on surge currents and during SSB or CW transmission when powered from a battery supply The voltage may drop each time the power requirement peaks If the voltage continues to be below 11 0V for more than 5 secon...

Page 7: ...d off Red ON Voltage too high Blink Voltage good waiting for reset Yellow ON Voltage too low Blink Voltage good waiting for reset Short Interval Blink Battery Save Mode USB Programming Instructions Download and install the West Mountain Radio port diagnostics utility or use another terminal program such as Hyper Term During installation be sure to install the drivers on the PC The utility can be s...

Page 8: ...st Mountain Radio diagnostics utility program Find the PWRguard Plus in the list of devices Right click on the PWRguard Plus and select TEST When the terminal window pops up press enter in the terminal area and the following menu will appear West Mountain Radio PWRguard 1 14 1 Reset to factory settings 2 View Change Settings 3 Monitor mode 4 Force output ON 5 Force output OFF Function 0 If enter 2...

Page 9: ...to defects in workmanship or materials for one year after the date of purchase from West Mountain Radio Warranty does not cover damage caused by abuse accident misuse improper or abnormal usage failure to follow instructions improper installation alteration lightning or other incidence of excessive voltage or current If failure occurs within this period return the PWRguard Plus or accessory to Wes...