West Mountain Radio PWRguard PLUS Operating Manual Download Page 3

3

West Mountain Radio

Operating Manual

Installation

1.  Install the PWRguard PLUS between the power source and the 

loads to be protected.

 

NOTE:  The unit comes fitted with Powerpole® connectors for ease 

of installation into your power system. 

Input (power source) connects on the left side of the case. 

Output (load) connects on the right side of the case.

 

Make sure that you only connect the RED lead to POSITIVE, and the 

BLACK lead to NEGATIVE.

2.  Install the unit in a cool dry location.  The case may be fastened 

down using the mounting holes on the flanges.

3.  The external sense terminal is located within the unit. Remove the 

case and locate the small terminal-block on the left hand side. The 

terminal nearest the edge of the board pr5VDC through a 

330 ohm resistor and the right terminal is the sense input.

 

The piezo buzzer alarm can be disabled by removing the jumper 

from the terminal post marked “Buzzer”.

4.   When the power supply is switched on, the PWRguard Plus unit will  

become operational and the AUTO RESET and ON LEDs will   

both glow green. If the AUTO RESET LED does not turn on, hold  

the reset button down for 5 seconds until it does. If the YELLOW 

LED (Low fault) comes on instead of the ON LED, it means that your 

power supply or battery voltage is too low. PWRguard Plus requires 

at least 13 (+/- 0.1) volts to become operational when turned on.  If 

supply voltage range is between 11-13V, you will need to manually 

turn on by pushing reset.

 

This setup integrates PWRguard Plus into a UPS. The PWRGuard 

Plus input is connected to the output of the Super PWRgate. The 

PWRguard Plus output is connected to the input of the RIGrunner. 

This setup will protect the battery from deep discharge after an AC 

power loss, and all devices that are plugged into the RIGrunner from 

under and over voltage. After AC power is restored, the battery will 

be recharged through the Super PWRgate and PWRguard Plus will 

reset the system. 

5V DC

Sense Input

Buzzer Jumper

USB Programming Connector

Summary of Contents for PWRguard PLUS

Page 1: ...tainradio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2016 West Mountain Radio All rights reserved All trademarks are the property of their respective owners PWRguard PLUS ...

Page 2: ...d if you do not need an audible alert Modes of Operation Automatic and Manual Automatic Mode Supply Voltage Not In Normal Range When the supply voltage is outside of the normal range the PWRguard PLUS will disconnect the load Upon restoration of normal supply voltage the load will be reconnected automatically Sense Input Triggered When the sense input is activated the PWRguard PLUS will disconnect...

Page 3: ...inal post marked Buzzer 4 When the power supply is switched on the PWRguard Plus unit will become operational and the AUTO RESET and ON LEDs will both glow green If the AUTO RESET LED does not turn on hold the reset button down for 5 seconds until it does If the YELLOW LED Low fault comes on instead of the ON LED it means that your power supply or battery voltage is too low PWRguard Plus requires ...

Page 4: ...0S output terminal and then plug the PWRguard PLUS output into the RIGrunner input terminal This will provide protection for the battery and all the devices that are plugged into the RIGrunner Additionally after loss of AC mains power the PWRguard PLUS will reset the system after the power is restored Integrated Set Up ...

Page 5: ...reset mode the RED LED will turn off when the input voltage returns to less than 15V and the output will turn ON thereby relighting the GREEN LED and re powering the load YELLOW LED Low Fault The YELLOW LED low fault will light whenever the input voltage drops below 11 0V This LED will also briefly light if there are momentary dips below 11 0V This feature assures correct operation during turn on ...

Page 6: ...low fault will light whenever the input voltage drops below 11 0V This LED will also light briefly if there are momentary dips below 11 0V This feature assures correct operation during turn on surge currents and during SSB or CW transmission when powered from a battery supply The voltage may drop each time the power requirement peaks If the voltage continues to be below 11 0V for more than 5 secon...

Page 7: ...d off Red ON Voltage too high Blink Voltage good waiting for reset Yellow ON Voltage too low Blink Voltage good waiting for reset Short Interval Blink Battery Save Mode USB Programming Instructions Download and install the West Mountain Radio port diagnostics utility or use another terminal program such as Hyper Term During installation be sure to install the drivers on the PC The utility can be s...

Page 8: ...st Mountain Radio diagnostics utility program Find the PWRguard Plus in the list of devices Right click on the PWRguard Plus and select TEST When the terminal window pops up press enter in the terminal area and the following menu will appear West Mountain Radio PWRguard 1 14 1 Reset to factory settings 2 View Change Settings 3 Monitor mode 4 Force output ON 5 Force output OFF Function 0 If enter 2...

Page 9: ...to defects in workmanship or materials for one year after the date of purchase from West Mountain Radio Warranty does not cover damage caused by abuse accident misuse improper or abnormal usage failure to follow instructions improper installation alteration lightning or other incidence of excessive voltage or current If failure occurs within this period return the PWRguard Plus or accessory to Wes...