background image

 Liberty Open - Operator & Maintenance Manual 

7. Defects

 

Check for any signs of defects? 

 

 

8. Safe Working Load

 

Subject to the repairs, renewals or alterations          (If any) stated in 

section 6, what is the safe working load of the lift? 

 

 

9. Other Observations

 

 

 

10. Declaration

 

 

 

 

 

 

I/We certify that on the date below, I/we thoroughly examined this lift and that the foregoing is a correct report of 

the examination. 

 

Signature(s): 

        

 

Position: 

 

Service Engineer 

Service Engineer 

Address(es): 

 

 

 

 

Date: 

 

 

Kg 

OP00 7100_A.doc 

Page 

22

 of 

34

 

 

Summary of Contents for LIBERTY OPEN

Page 1: ...LIBERTY OPEN OPERATOR MAINTENANCE O M MANUAL Wessex Lift Co Ltd Budds Lane Romsey Hampshire SO51 OHA UK OP00 7100 Revision A October 2013...

Page 2: ...ovided that such electronic or printed copy of this manual or revision must contain the complete text of this copyright notice and provided further that any unauthorised commercial distribution of thi...

Page 3: ...all Stations Internal Standard Controls 8 4 2 In Car Internal Standard Controls 2 Stop 8 4 3 Sensitive Safety devices Safety Edges 9 4 4 Gate Interlocks 9 4 5 Operation of the Platform lift Overview 1...

Page 4: ...ce today Our in depth knowledge of associated building and electrical work and management expertise ensures that the installation of all Wessex Equipment is completed with the minimum of disruption to...

Page 5: ...r purposes other than those described in the manual Material must not be transported unattended in the lift Components higher than 2 2 metres must not be transported in the lift 2 3 WARNING Overload D...

Page 6: ...switch as follows 1 Open the pump box enclosure and trip the MCB 2 Switch off the lift units main power switch lock and tag and place a warning sign prominently at each platform lift entrance advising...

Page 7: ...g the relevant optional extras 3 3 Safety Gear The use of rupture valves prevents the rapid descent of the lift in the event of a hydraulic hose or pump failure 3 4 Platform Sizes OP01 1460 x 800 OP02...

Page 8: ...stop the lift in the event of an emergency press the red emergency stop button The button will stay locked down The lift will not work when the stop button is in this position To release twist the re...

Page 9: ...carrier comes into contact with an obstruction the lift will stop The lift can only be restarted once the obstruction has been removed 4 4 Gate Interlocks Notes Latch Plate removed for clarity Gate t...

Page 10: ...t pressure i e the buttons must be kept depressed throughout the travel If released the platform lift will stop immediately When the platform lift reaches the correct landing it will stop automaticall...

Page 11: ...the options selected on purchasing the lift Entering Exiting the Lift The lift can be configured to allow the user to enter and exit the lift without the need to reposition their wheelchair or other...

Page 12: ...in car directional control button wait 3 seconds and then select the new direction of travel button The lift will then move in the new direction Alternatively the original direction of travel can be...

Page 13: ...e The lift incorporates a facility that will allow the lift to be lowered to the ground floor in the event of a power failure 1 In the event of a power failure the lower Green directional arrow will i...

Page 14: ...se key in a convenient place in case of an emergency 2 Pull the red solenoid knob and the lift will lower towards the ground releasing the knob will stop the platforms descent When the platform has re...

Page 15: ...before manually opening the Gate Remove the rubber grommet on the Gate lock infill Align and insert the gate release key provided Twist approximately turn and pull the Gate open Note It is recommende...

Page 16: ...use ladders to clean the exterior of the lift or the interior panels by balancing ladders on the platform If you wish your lift to be cleaned we recommend that you use a 3rd party contractor or conta...

Page 17: ...the Gates are closed and interlocked Ensure that the mains power is turned on Ensure that the lift is not isolated via a key switch this will result in the call buttons not being illuminated check la...

Page 18: ...nd ask for The Customer Care department A member of staff will record details of your request and initiate the necessary actions to resolve the problem Outside normal office hours telephone the emerge...

Page 19: ...n accordance to BS 6440 2011 standard Annex E which includes but is not limited to the following Interlocking devices Electrical safety devices Earth continuity Supporting and suspensions means for li...

Page 20: ...riod Months Engineers Name Company Signature Date 3 6 12 1 Year 18 24 2 Years 30 36 3 Years 42 48 4 Years 54 60 5 Years 66 72 6 Years 78 84 7 Years 90 96 8 Years 102 108 9 Years 114 120 10 Years Circu...

Page 21: ...sure Oil levels seals Guide rails tracks and fixings Hydraulic components Push buttons Batteries Pads and Guides Door mechanism Trailing cables Door Gate Interlocks Wiring and fuses Door locks Isolato...

Page 22: ...ons If any stated in section 6 what is the safe working load of the lift 9 Other Observations 10 Declaration I We certify that on the date below I we thoroughly examined this lift and that the foregoi...

Page 23: ...0mm Lift Access Configurations Through Access and LH RH Side Access Clear opening width1 800mm 1460 x 800 900mm 1460 x 900 1460 x 1100 Clear Opening Height Required1 2000mm Light at lifting platform f...

Page 24: ...on Not regarded as a health or environmental hazard under current legislation 4 First Aid Measures Inhalation Move the exposed person to fresh air at once Get medical attention if any discomfort conti...

Page 25: ...container 8 Exposure Controls and Personal Protection Ingredient Comments OES Occupational Exposure Standard MEL Maximum Exposure Limit Protective Equipment Ventilation Provide adequate general and lo...

Page 26: ...Toxicological Information Health Warnings No specific health warnings noted 12 Ecological Information Ecological Information Dangerous for the environment if discharged into watercourses 13 Disposal...

Page 27: ...R Phrases Full Text R 36 Irritating to eyes R 51 53 Toxic to aquatic organisms may cause long term adverse effects in the aquatic environment Disclaimer The information provided in this document has...

Page 28: ...hetic Mineral oils are generally low hazard products They may cause slight temporary irritation if splashed in the eye They may cause slight skin irritation following frequent or prolonged skin contac...

Page 29: ...requirements avoid elevated temperatures Suitable Materials Coatings Most common metals and plastics are suitable for storage Unsuitable Materials Coatings Product may soften some rubbers 9 Reactivity...

Page 30: ...itation of lung tissue which may give rise to chemically induced pneumonia children are more susceptible than adults Carcinogenicity No carcinogenic effects are normally associated with these products...

Page 31: ...The use of suitable skin barrier cream can be beneficial Observe good standards of personal hygiene Keep exposure to oil mists and fumes to a minimum 15 Packaging Labelling and Transport Classificati...

Page 32: ...N Model OP01 OP02 OP03 Enclosed Platform Lift Manufacturer Wessex Lift Co Ltd Address Budds Lane Romsey Hampshire SO51 0HA Telephone No 44 0 1794 830 303 Fax No 44 0 1794 512621 E Mail info wessexlift...

Page 33: ...lines 1 The Lifting Platform should be thoroughly examined by a technically competent person at intervals not exceeding six months as recommended in EN 81 41 2010 2 Paint work or any other damage iden...

Page 34: ...5 EC Electromagnetic Compatibility Directive 2004 108 EC Conformity Assessment Procedure As defined in Regulation 13 of Supply of Machinery Safety Regulations 2008 Conformance of a type sample with th...

Reviews: