17
PROBLEM: The walking belt slows when walked on
SOLUTION:
a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 10.
b. If the walking belt is overtightened, treadmill perfor-
mance may decrease and the walking belt may be-
come damaged. Remove the key and
UNPLUG THE
POWER CORD.
Using the hex key, turn both idler
roller bolts counterclockwise, 1/4 of a turn. When the
walking belt is properly tightened, you should be able
to lift each edge of the walking belt 2 to 3 in. (5 to 7
cm) off the walking platform. Be careful to keep the
walking belt centered. Then, plug in the power cord,
insert the key, and run the treadmill for a few minutes.
Repeat until the walking belt is properly tightened.
c. If the walking belt still slows when walked on, please see the front cover of this manual.
PROBLEM: The walking belt is off-center or slips when walked on
SOLUTION:
a.
If the walking belt has shifted to the left,
first re-
move the key and
UNPLUG THE POWER CORD.
Using the hex key, turn the left idler roller bolt clock-
wise 1/2 of a turn. Be careful not to overtighten the
walking belt.
If the walking belt has shifted to the
right,
turn the left idler roller bolt counterclockwise 1/2
of a turn. Then, plug in the power cord, insert the key,
and run the treadmill for a few minutes. Repeat until
the walking belt is centered.
b. If the walking belt slips when walked on, first remove
the key and
UNPLUG THE POWER CORD.
Using
the hex key, turn both idler roller bolts clockwise, 1/4
of a turn. When the walking belt is correctly tightened,
you should be able to lift each edge of the walking
belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be
careful to keep the walking belt centered. Then, plug
in the power cord, insert the key, and carefully walk
on the treadmill for a few minutes. Repeat until the
walking belt is properly tightened.
b
a
b
2–3 in.
Idler Roller
Bolts