*All products subjected to fall arresting 

forces should be removed from service 

immediately!

DECK/FLOOR/GROUND LEVEL

WORK SURFACE

WORK SURFACE

(ANCHOR POINT)

*The user shall be equipped with a means of 

limiting  the maximum dynamic forces exerted 

on the user during the arrest of a fall to a 

maximum of 8 kN (1800-lbf). In the EU these 

forces must be limited to 6kN (1350-lbf).

W

ARNING!!! SWING F

ALLS M

AY OC

CUR 

WHEN 

THE 

W

ORKER IS NO

T DIREC

TL

Y UNDER ANCHOR POINT

.  

Inspect retaining 

bushing for wear 

or damage.

MINIMUM CLEARANCE 2 feet (.6m) 

 

Summary of Contents for A555000

Page 1: ...MILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT ALL USERS OF THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE AVOID CONTACT WITH PHYSICAL HAZARDS THERMAL CHEMICAL ELECTRICAL ETC MAKE ONLY COMPATIBLE CONNECTIONS V2 1 B Patent US 8 312 966 US 8 646 575 US 8 973 705 B2 BANTAM BEAMER ADJUSTABLE FROM 3 5 14 inches Model A555000 ...

Page 2: ...ge connector must be removed from service and destroyed immediately USE LIMITATIONS This anchorage connector has been tested in compliance with the requirements of ANSI ASSE Z359 7 Compliance testing covers only the hardware and does not extend to the anchorage and substrate to which the anchorage connector is attached The anchorage connector must not be used outside its limitations or for any pur...

Page 3: ...ized beam D ring is centered on the anchorage connector for ease of sliding on beam flanges Particularly in rope access applications bodyweight may disengage the centering feature in some loading conditions This is not a safety concern but it may affect usability Adjustable Directions Notches Latch Handle Notches Latch Handle Adjustable Hook Adjustable Hook PERFORMANCE Minimum Breaking Strength 50...

Page 4: ... an ANSI Z359 compliant energy absorbing connecting component Energy Absorbing Lanyard or Self Retracting Lifeline and free fall limits of the connecting component must be followed The beam anchor must be attached to the I beam flange facing the user top flange if above bottom flange if below etc ...

Page 5: ...user shall be equipped with a means of limiting the maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 8 kN 1800 lbf In the EU these forces must be limited to 6kN 1350 lbf WARNING SWING FALLS MAY OCCUR WHEN THE WORKER IS NOT DIRECTLY UNDER ANCHOR POINT Inspect retaining bushing for wear or damage MINIMUM CLEARANCE 2 feet 6m ...

Page 6: ...el A555000 Batch XXXX Compliance OSHA 1926 502 OSHA 1910 140 ANSI Z359 18 Type A ANSI Z359 7 19 EN 795 2012 Type B CE 2777 Stainless Steel Aluminum Zinc Plated Steel Bronze Pat US 8 312 966 US 8 646 575 US 8 973 705 B2 MAX 1 888 523 3371 P N 112573 07 REV C 1 21 P N 112573 04 REV E 5 21 2777 WARNING ALL USERS OF THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS FAILURE TO DO SO MAY RESULT I...

Page 7: ...fficial periodic inspection must be made at least annually The inspection must be performed by a competent or qualified person other than the intended user If severe environmental conditions exist then inspections must be carried out more frequently All inspection results must be logged in the space provided above It is recommended that the anchor device is marked with the date of the next or last...

Page 8: ...125 1 888 523 3371 www wernerco com 105548 05 REV F 5 21 Notified Body responsible for the EC type examination and ongoing conformity SATRA Technology Europe Ltd Bracetown Business Park Clonee Dublin D15 YN2P Ireland Tel 353 0 1 437 2484 2777 ...