![background image](http://html.mh-extra.com/html/werma/kombisign-71/kombisign-71_manual_957204006.webp)
WERMA SIGNALTECHNIK
Version 1.2.0 - 0911
6
2.3
Safety instructions
Caution!
-
Please also refer to the instruction leaflet for your WERMA signal tower.
-
The USB terminal element is not suitable for safety critical applications.
-
For use with 24 V WERMA signal elements with max. 90 mA.
2.4
Technical data
Operating voltage
5 V DC (USB)
Output voltage
24 V DC (+/- 10 %)
Current consumption
Typ. 500 mA
Output current
Max. 90 mA
Min. operating temperature
- 25 °C
Typ. operating temperature
+ 25 °C
Max. operating temperature
+ 60 °C
The signal tower elements can be triggered directly from a PC or Laptop via a standard USB
interface. The USB port must deliver min. 500 mA, if not a USB-Hub with external power supply
must be used.