28
Web-based Configuration
PoE information (ZAC50PN0x):
The switch monitors the current PoE power consumption constantly. The webpage shows the maximum avail-
able PoE performance of the switch as well as the currently reserved and outgoing PoE performance.
Every PoE device registers in a specific PoE performance class when starting. This performance is then re-
served in the switch. Mostly, the maximum reserved performance is not demanded, however. It is possible to
optimally utilize the maximum PoE performance of the switch by deactivating the PoE performance monitoring.
If the PoE performance monitoring is deactivated, this can cause performance impairments of the device. In
this case, the maximum output PoE performance must not be more than the maximum PoE performance of
the switch. If the performance monitoring is deactivated, this is displayed on the switch with a red flashing PoE
max LED. During operation, the performance monitoring can be changed from inactive to active. Here, all PoE
devices are restarted automatically in order to save the reserved performance of the individual ports.
Change password:
An additional window opens, in which the new password can be entered.
Please note: If you forget the password, the switch can only be set to the delivery state via a reset on
the controller.
Reset:
The following settings can be reset to the delivery state by pressing the “Reset” button.
• Parameter of the digital I/O ports: All digital I/O ports are switched to input
• Parameter PoE: PoE monitoring is switched to one and on all ports
the PoE power supply is activated
• The password is reset to the delivery state (“admin”)
Please note: The network settings are not reset hereby! If you do not know the network settings, the
device must be connected to a controller in order to reset the settings.