background image

Operating instructions

ZAC5xPN0x

Ethernet Switches

EN

Translation of the Original Operating Instruction

Subject to change without notice

Available as PDF version only

Status: 22.01.2020

www.wenglor.com

Summary of Contents for ZAC5 PN0 Series

Page 1: ...Operating instructions ZAC5xPN0x Ethernet Switches EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Status 22 01 2020 www wenglor com...

Page 2: ...dustrial Ethernet Cable with Power over Ethernet 15 7 6 Connecting Digital Sensors and Actuators 15 7 7 Diagnosis 16 7 7 1 LED Display PROFINET Device ZAC50PN0x 16 7 7 2 LED Display PROFINET Device ZA...

Page 3: ...Industrial Ethernet there are several digital inputs and outputs directly on the switch that can be activated or evaluated via the network 2 Safety Precautions This operating instruction is part of t...

Page 4: ...1 4 pin D coding M12 1 4 pin D coding M12 1 4 pin D coding Type of Connection PoE Ports M12 1 8 pin type x M12 1 8 pin type x Type of Connection Digital I O ports M12 1 4 pin A coding M12 1 4 pin A c...

Page 5: ...nglor com 77 50 Suitable Plug 51 Suitable Plug 2 Suitable Plug 78 77 50 50 Socket 1 Socket 1 51 2 Socket 2 Socket 3 77 Socket 4 51 2 Socket 2 Socket 3 78 Socket 4 50 50 Socket 1 Socket 1 50 Socket 1 F...

Page 6: ...Socket 3 Suitable Plug 77 Function Pin 1 24 V DC 2 I O 3 4 Socket 1 GND I O Suitable Plug 5 Function Pin 1 0 V DC 2 0 V DC 3 4 24 V DC USystem 5 24 V DC UDigital I O Sensor 51 78 77 Suitable Plug 2 54...

Page 7: ...7 Industrial Communication 4 3 Housing Dimensions 4 3 1 ZAC5xxN01 4 3 2 ZAC50xN02...

Page 8: ...oducts Connection plug 7 8 5 pin Order number ZAT77NN01 Suitable Plug 77 S82 Connection socket 7 8 5 pin Order number ZAB78NN01 Suitable Plug 78 Connecting cable 7 8 5 pin Order number ZAV78R201 Cable...

Page 9: ...onnecting line 7 8 5 pin Order number ZAS78R601 Cable length 10 m Suitable Plug 78 S75 Connector Plug RJ45 8 pin Order number ZAT45NN01 Suitable Plug 45 S48 Connection plug M12 1 8 pin Order number ZA...

Page 10: ...m Order number ZAV50R501 Cable length 5 m Suitable Plug 50 S81 Order number ZAV50R502 Cable length 5 m Suitable Plug 50 S85 Connecting line M12 1 8 pin Order number ZAS50R601 Cable length 10 m Suitabl...

Page 11: ...ine Emitter Line Grounding Switching Distance Reduction Ethernet Receive Path Ethernet Send Path Interfaces Bus A B Emitted Light disengageable Magnet activation Input confirmation Contactor Monitorin...

Page 12: ...al sector business and commercial sectors The table below defines the tightening torques of the plugs and fastening options for ensuring compliant and faultless operation Connection type Tightening to...

Page 13: ...esigned for a maximum current of 9 A per pin This must be taken into account when looping the supply voltage The switch must be connected to a power supply of 18 to 32 V DC The USystem Sensor supplies...

Page 14: ...ices 7 3 Functional Earth The FE connection is on the lower front edge of the switch To ensure proper functioning in accordance with the EMC regulations specified in the data sheet we recommend using...

Page 15: ...ff on at least one of the two PoE ports see Industrial Ethernet Ports Settings on page 29 Assignment of the Industrial Ethernet connection with PoE 1 2 3 4 5 6 8 7 Pin Function 1 TxD 2 TxD 3 RxD 4 RxD...

Page 16: ...OUT Power Power www wenglor com ZAC50PN01 ZAC50PN02 ZAC51PN01 7 7 1 LED Display PROFINET Device ZAC50PN0x CS MS PoE max The status displays for the communication are marked on the switch with CS and...

Page 17: ...ng output at UB Pin 2 4 Red Output Short circuit at Pin 2 4 7 7 2 LED Display PROFINET Device ZAC51PN01 CS MS The status displays for the communication are marked on the switch with CS and MS Designat...

Page 18: ...ondition Function L A Green Link exists Green flashing Communication via port X0 IO 0 0 IO 1 0 Designation Condition Function IO 0 0 IO 1 0 Yellow Input UB at Pin 2 4 Output Switching output at UB Pin...

Page 19: ...matic S7 controller from Siemens Insert the device into the PROFINET cable Afterwards call up the object properties of the device Assign a name of your choice to the device Allocate an Ethernet addres...

Page 20: ...ty Port2 BitArea 0 1 1 1 Enabled Yes 258 1 byte PoE Functionality Port3 BitArea 0 2 1 1 Enabled Yes 258 1 byte PoE Functionality Port4 BitArea 0 3 1 1 Enabled Yes 258 1 byte PoE Functionality Port5 Bi...

Page 21: ...igital in out Module ID 0x00000001 Submodule 0x00000001 Format cyclical input and output data Example x1P4 Digital I O Port 1 Pin 4 ZAC5xPN0x Input Output Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit...

Page 22: ...pi 0x00000000 Slot 0x0001 Subslot 0x0001 Channel 1 Port 2 Pin2 2 Port2 Pin4 3 Port4 Pin2 4 Port4 Pin4 AlarmSpecifier 0x01 Diagnosis appears ChannelErrorType 0x0100 manufacturer specific Diagnostic I O...

Page 23: ...ndependent monitoring or a test environment to be set up It is not needed for normal operation on the controller Attention When using on a controller settings changed through the website are overwritt...

Page 24: ...24 Web based Configuration...

Page 25: ...s line of the browser Example http 192 168 100 1 delivery state The overview page Device General is not password protected If the pages of the device or port settings are accessed a password prompt ap...

Page 26: ...on 8 2 Overview page After the connection is established the overview page of the switch is displayed Through the language selection the website can be changed from English delivery state to German It...

Page 27: ...he switch briefly from the power supply WARNING Error free operation of the product can only be guaranteed if the correct network settings are entered in the web user interface Any incorrect entry of...

Page 28: ...rformance monitoring is deactivated this is displayed on the switch with a red flashing PoE max LED During operation the performance monitoring can be changed from inactive to active Here all PoE devi...

Page 29: ...on the uppermost level The Industrial Ethernet ports contain information on the number of packages received correctly and incorrectly as well as packages sent correctly In addition to the information...

Page 30: ...digital inputs outputs each The digital inputs outputs are configured on the Digital I O Ports page Pin 2 and pin 4 can each be configured as input or output If the pin is configured as output the pin...

Page 31: ...ive residues can be cleaned using aromatic free white spirit or isopropyl alcohol IPA Use cleaning agent at a maximum of 25 C Never use steam cleaners Never use solvents with aromatic compounds alcoho...

Page 32: ...glor shall only assume liability if it can be proved that wenglor had knowledge about for the errors in question at the time of creating the operating manual This operating manual is only a general de...

Reviews: