21
4. Technical Data
Electrical Data
Temperature Range
–25…60 °C
Storage Temperature
–40…85 °C
Supply Voltage
20,4…28,8 V DC
20,4…26,4 V AC
Input Circuitry
1-, 2-channel
Response Time (start automatic)
typ. 120 ms
Response Time (start monitored)
≤
25 ms
Drop-out Time (emergency stop) (stop 0)
typ. 15 ms, max. 20 ms
Drop-out Time (emergency stop) (stop 1)
0,1...30 s
Drop-out Time (mains failure)
≤
55 ms
Power consumption
2.4 W / 5.9 VA plus signal output
Frequency range
50 Hz/60 Hz
Fuse rating for the operating voltage
Internal electronic trip,
tripping current F1: > 750 mA;
tripping current F2: > 75 mA;
Reset after disconnection of supply voltage;
tripping current F3: > 140 mA
Current and voltage at S11, S12, S21, S22
24 V DC, 10 mA
Current and voltage at X1, X2
24 VDC, start impulse, 25 mA / 25 ms
Current and voltage at X1, X3
24 VDC, start impulse, 950 mA / 10 ms
Utilisation category (EN 60947-5-1)
Stop 0: AC-15: 230 V AC/6 A
DC-13: 24 V DC/5 A
Stop 1:
AC-15: 230 V AC/3 A
DC-13: 24 V DC/2 A
Contact resistance in new state
max. 100 m
W
Safety Output
Safety Output
NO
Safety Outputs Stop 0
2
Safety Outputs Stop 1
1
Switching capacity Safety Output Stop 0 (250 V)
8 A ohmic (inductive in case of appropriate protective
wiring); min. 5 V / 5 mA
The derating curve must be taken into account
Switching capacity Safety Output Stop 1 (250 V)
6 A ohmic (inductive in case of appropriate protective
wiring); min. 10 V / 10 mA
The derating curve must be taken into account
Fuse rating safety output stop 0
external (Ik = 1000 A) to EN 60947-5-1
Safety fuse 10 A quick blow, 8 A slow blow
Fuse rating safety output stop 1
external (Ik = 1000 A) to EN 60947-5-1
Safety fuse 8 A quick blow, 6,3 A slow blow
Signal Output
Signal Output
semiconductor
Number of Signal Outputs
1
Signal Output Switching Current (24 V DC)
100 mA
Fuse rating Signal Output
100 mA (internal electronic trip F4)