Type 4 Safety Light Curtain
7.2 Overview of All Functions
Emitter Settings
Receiver Settings
Range
Safety mode without contactor
monitoring
Test function
Safety mode with contactor monitoring
Start-up and restart inhibit without
contactor monitoring
Start-up and restart inhibit with
contactor monitoring
Signal output
NOTE!
In order to accept the modified configuration, a test object must be passed through the safety
field (beginning at the sensor connection on the control panel side up to the other end) within
30 seconds after electrical connection and activation of supply voltage. Interruption is con-
firmed by LED DIAG3 at the receiver.
This is always necessary when switching to a “less safe” operating mode:
• From restart inhibit to safety mode
• From contactor monitoring to operation without contactor monitoring
An overview of parameters configuration for the receiver is included in the index
(see section “12.2 Overview of Receiver Parameters Configuration” on page 63)
.