7.3 Locking

If 18 to 30 V DC is continuously applied to the teach-in input, the teach-in key is locked and protected against 
inadvertent changes.

1. Change the A1/A2/E3 pin function to external teach-in.
2. Permanently connect pin A1/A2/E3 to voltage within a range of 18 to 30 V DC.
3. The sensor is protected against inadvertent changes caused by the teach-in key.

7.4 Switchable Emitted Light

Emitted light from the sensor can be switched off by means of an IO-Link parameter. Beyond this, the sen-
sors’ inputs can be programmed via IO-Link so that the “switchable emitted light” function can also be activat-
ed by applying 24 V to the respective input.

7.5 External Teach-In

Teach in output A1/A2 via the teach-in input. 

1. Set the pin function for I/O1 or I/O2 to external teach-in input using IO-Link or wTeach.
2.  Connect the pin selected for use as an input to 24 V in order to teach-in switching output 1 (2 sec.) and 

switching output 2 (5 sec.). 

3. As soon as voltage drops at the input, the outputs are taught in.
 

NOTE!
Please note that during external teach-in via one of the two configurable output pins, both 
independent switching points are stored to the sensor and can be read out at any time via 
the process data using IO-Link. If both outputs need to be evaluated via the pins, the previ-
ously configured teach-in input must be configured once again as an output. 
If the La function (switchable emitted light) is not needed, pin 5 (I3 pin function) can also be 
used as a teach-in input, in order to teach-in switching outputs O1 and O2 using the proce-
dure described in point 2. 

7.6 Error output

The error output is switched in the following cases:

• Signal from object too weak
• Incorrect installation
• The object is located outside of the working range.

Summary of Contents for P1PY0 Series

Page 1: ...ructions EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 1 0 Status 01 04 2019 www wenglor com P1PY0xx High Performance Di...

Page 2: ...1 Spot diameter 8 3 3 Accessory Products 9 3 4 Layout 10 3 5 Control Panel 11 3 6 Scope of Delivery 11 4 Transport and Storage 11 4 1 Transport 11 4 2 Storage 11 5 Installation and Electrical Connecti...

Page 3: ...eans of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in accorda...

Page 4: ...proved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product charact...

Page 5: ...owing industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry Plastics industry Woodworki...

Page 6: ...arking and the guarantee may be rendered null and void Modification of the product is impermissible 2 5 General Safety Precautions NOTE These instructions are an integral part of the product and must...

Page 7: ...re drift 10 C Tu 50 C 1 Temperature drift Tu 10 C Tu 50 C 2 5 Temperature range 40 60 C Number of switching outputs 2 Switching output voltage drop 2 5 V Switching output PNP switching current 200 mA...

Page 8: ...mm Table 1 3 2 Switching Distance Deviation Typical characteristic curve based on Kodak white 90 remission P1PY 0 500 1000 1500 2000 2500 3000 5 0 7 5 2 5 0 0 2 5 5 0 7 5 10 0 Sr mm dSr mm Sr switchi...

Page 9: ...cessory Products wenglor can provide you with suitable connection technology for your product Suitable connection technology no 2 S02 35 S06 IO Link master wTeach2 software DNNF005 Protective Housing...

Page 10: ...10 Technical Data 3 4 Layout P1PY001 P1PY003 P1PY002 P1PY004 1 receiver diode 2 emitter diode M4 screw 0 5 Nm Dimensions specified in mm 1 mm 0 03937...

Page 11: ...n transit In the case of damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following point...

Page 12: ...ted in a mechanically secure fashion Specified torque values must be complied with see section 3 4 Layout page 10 ATTENTION Risk of property damage in case of improper installation The product may be...

Page 13: ...priately qualified personnel 5 3 Diagnostics Causes for Triggering the Contamination Warning A1 A2 Continuous blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz...

Page 14: ...bject off off on off off off off blinking off Required action in case of fault NOTE Shut down the machine Analyze and eliminate the cause of error with the help of the diagnostics information If the e...

Page 15: ...t 1 lights up in order to confirm successful teach in Foreground Teach In for Switching Output 2 1 Mount the sensor in accordance with the mounting instructions 2 Position the object in front of the s...

Page 16: ...r to the background 3 Configure or teach in the switching output the switching output function via IO Link 4 The sensor is switched as soon as an object is located between the background and the senso...

Page 17: ...I O2 to external teach in input using IO Link or wTeach 2 Connect the pin selected for use as an input to 24 V in order to teach in switching output 1 2 sec and switching output 2 5 sec 3 As soon as v...

Page 18: ...d damage the product The product must be protected against contamination during initial start up 9 Proper Disposal wenglor sensoric GmbH does not accept the return of unusable or irreparable products...

Reviews: