background image

12

EN

Fig. 1: Set language menu

Navigation by pressing the button:

5  

: Navigation up.

6  

: Navigation down.

  

: Enter Button.

The selection is confirmed by pressing the Enter button.

Meaning of the menu items:

3

Back 

: one level higher in the menu.

7

Run 

: Switch to display mode.

Change to the configuration menu by pressing any button.

Note:

 If no setting is made in the configuration menu for a period of 30 s, the Sensor returns automatically to 

the display view.
Pressing the button again returns the Sensor to the last menu view used. If a setting is made, it becomes active 
once you leave the configuration menu.

Important:

 To prevent any damage to the buttons, please do not use any pointed objects for setting.

The following explains the functions behind the individual menu items.

Summary of Contents for OY2TA104P0150E

Page 1: ...4P0150E High Performance Distance Sensor Operating Instructions Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Status 03 09 2019 www w...

Page 2: ...ons 7 3 3 Control Panel 8 3 4 Complementary Products 9 4 Mounting Instructions 9 5 Initial Operation 9 5 1 Operation using a controller without EDS file use 9 5 2 Default Settings 10 6 Functional Over...

Page 3: ...F5 23 7 7 Ethernet link object 0xF6 24 7 8 QoS object 0x48 25 7 9 Vendor specific object 0x64 26 7 9 1 Configuration assemblies 26 7 9 2 Static input assembly 26 7 9 3 Vendor object 27 8 Web based con...

Page 4: ...lined positions It is possible to mount sev eral sensors next to or across from each other without them influencing each other 2 Safety Precautions 2 1 Safety Precautions This operating instruction is...

Page 5: ...er Class EN 60825 1 1 Beam Divergence 2 mrad Light Spot Diameter see table 1 Port Type 100BASE TX PoE Class 1 Response Time 10 ms Temperature Range 25 50 C Reverse Polarity Protection yes Protection C...

Page 6: ...Input confirmation Contactor Monitoring Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Swi...

Page 7: ...7 3 2 Housing Dimensions 1 Transmitter Diode 2 Receiver Diode...

Page 8: ...off Operate status Green flashing Standby Red Serious error Red flashing Device error NS Network Status Off No IP address Green off CIP connection Green flashing IP configured no CIP connection Red Du...

Page 9: ...has been estab lished the display at the sensor will start Create a new project in the controller Add a new module to this project When selecting the communication module General Ethernet module shoul...

Page 10: ...y Mode Process Intensity Screensaver Filter 1 Laser ON Network IP Address 192 168 100 1 Subnet Mask 255 255 255 0 DHCP DHCP OFF Std Gateway 192 168 100 254 MAC Address See type plate on the product La...

Page 11: ...Mode Enable Change Lock Language Info Reset Password Run Min Medium Max Power save Screensaver Process Text Analyse Network Mode Rotate Intensity Display Filter 1 10 100 2 20 5 50 Laser On Off E A Te...

Page 12: ...ration menu by pressing any button Note If no setting is made in the configuration menu for a period of 30 s the Sensor returns automatically to the display view Pressing the button again returns the...

Page 13: ...he button the display is rotated by 180 The rotation is canceled by pressing this button again Intensity Set the display intensity see chapter 7 2 2 6 2 1 Display Mode The sensor display always shows...

Page 14: ...ed values over which the Sensor takes an average The larger the filter selected the slower the response time of the Sensor becomes when there is a change in the measured values A larger filter improve...

Page 15: ...ct too small The current measured value is below the working range Measuring range lower limit 3 Distance to object too large The current measured value is above the working range Measuring range uppe...

Page 16: ...he menu language can be changed in the menu item Language The user is automatically prompted for his desired language at initial operation and after each reset Language Set menu language Deutsch Engli...

Page 17: ...peration of the Sensor is disabled after supply power has been interrupted and is only enabled after successfully entering password Change Change password Lock Locking Sensor causes an immediate disab...

Page 18: ...nstance Get 3 Number of instances Get 6 Maximum ID number class attributes Get 7 Maximum ID number instance attributes Get Class services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Ins...

Page 19: ...sion Get 2 Max instance Get 3 Number of instances Get 4 Optional attribute list Get 5 Optional service list Get 6 Maximum ID number class attributes Get 7 Maximum ID number instance attributes Get Cla...

Page 20: ...x64 Assembly object object class ID 0x04 Class attributes ID Name Access 1 Revision Get 2 Max instance Get 3 Number of instances Get 6 Maximum ID number class attributes Get 7 Maximum ID number instan...

Page 21: ...utes Get 7 Maximum ID number instance attributes Get Class services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instance attributes ID Name Access 1 Open requests Get set 2 Open format...

Page 22: ...s Get 6 Maximum ID number class attributes Get 7 Maximum ID number instance attributes Get 8 Entry port Get 9 Port instance info Get Class services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_...

Page 23: ...ID number class attributes Get 7 Maximum ID number instance attributes Get Class services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instance attributes ID Name Access 1 Status Get 2 C...

Page 24: ...nstances Get 6 Maximum ID number class attributes Get 7 Maximum ID number instance attributes Get Class services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instance attributes ID Name...

Page 25: ...nce Get 3 Number of instances Get 6 Maximum ID number class attributes Get 7 Maximum ID number instance attributes Get Class services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instanc...

Page 26: ...char 19 of 19 25 Reserved1 1 The reserved byte at position 25 is required as padding The length field of the connection path is word based thus only allowing an even number of bytes for the configurat...

Page 27: ...ror Bit2 Dist to object too small Bit3 Dist to object too big Bit4 No signal Bit5 Signal too weak Bit6 Signal too strong Bit7 Warm up procedure Bit8 Temperature too high Bit9 Temperature too low Littl...

Page 28: ...r dflt 14 Display mode V USINT 8bit Get set 0 Process dflt 1 Analysis 2 Text 3 Network 15 Display language V USINT 8bit Get set 0 Deutsch 1 English dflt 2 Francais 3 Espanol 4 Italiano 16 Physical uni...

Page 29: ...verwritten by the controller 8 1 Opening the administration interface Launch the web browser Enter the manually configured IP address of the switch in the address bar of your browser and press the ent...

Page 30: ...30 EN...

Page 31: ...wser as described Example 192 168 100 10 The overview page Device general is not password protected If the pages of the device or port settings are opened a password query appears The following user d...

Page 32: ...e on the device itself 3 Category selection The web based settings are divided into four categories Device general Overview page with general information about the device Device settings Network and d...

Page 33: ...33 8 3 General device After the connection has been established the overview page General device is displayed 8 4 Device Settings...

Page 34: ...ed Any incorrect entry of values may result in the device no longer being accessible in the network It must be ensured that supply power is not interrupted while making changes to network settings Fur...

Page 35: ...Please note Settings are also preserved in the online state 9 Maintenance Instructions This wenglor Sensor is maintenance free It is recommended to clean the lens and the display regularly and to che...

Page 36: ...lity if it can be proved that wenglor had knowledge about for the errors in question at the time of creating the operating manual This operating manual is only a general description of technical proce...

Reviews: