background image

lBaxxxx

OpeRaTINg INSTRUCTIONS

P4/8

voLtage dRop

Dimensions

LBax101

LBax201

LBax301

LBax501

Max voltage drop in the bar (V)

0.01

0.03

0.06

0.12

Power supply cable : 4x1,5² max length 

for acceptable voltage drop (m)*

>150

* For longer power supply cable, increase the section of the copper wire.

CONTROl

STROBe pNp

 & 

NpN

pNp : from 5 to 24V for 100% ON. From 0 to 1V for 100% OFF.
NpN : less than 1V for 100% ON. Above 2V for 100% OFF. Max 20V.

Brightness

d max

t max

f max

100%

N/A

CW

N/A

100% to 240%

1/5

30 ms

30Hz

D : Duty Cycle
t : pulse duration
f : frequency

OpeRaTINg CONDITIONS

-10° to +40°C

 (14° to +104°F)

 / 80% of humidity without condensation.

No thermal shock (max temperature variation: 10°C 

(18°F)

 in 24h).

Not for outdoor use.

The product is optimised for a lifespan >50kh in a 40°C 

(104°F) 

atmosphere.

In strobe mode, the strobing time is directly equivalent to the time during which the strobe entry is activated.

Summary of Contents for LBA Series

Page 1: ...ge in writing on the delivery documents It is also your responsibility to notify wenglorTPL in wri ting of the damage within 24 hours of receipt of the package If these instructions are not followed wenglorTPL reserves the right not to accept requests for return and exchange of damaged products The applicable Standard EN 62471 classifies LED Lighting into 4 classes according to their degree of haz...

Page 2: ...ad the attachment points symmetrically along the bar You can also use M4 screws not supplied fastened directly into Aluminium profile with a tightening torque from 0 5 to 1 5 Nm We also recommend the use of a thread locker not supplied to avoid any risk of loosening LBAxxxx Operating instructions Total length mm Height mm Width mm Illumination length mm A B C D LBAx101 158 45 47 6 125 LBAx201 283 ...

Page 3: ...5 male points 24V 1 2 3 4 Ground PNP 5 Dim0 10V STROBEPNP 24V NPN 1 2 3 4 Ground STROBENPN 24V 1 2 3 4 Ground PNP 24V NPN 1 2 3 4 Ground CONTINUOUSMODE or 2 4 1 24V 3 GND 5 DIM0 10V STROBE NPN STROBE PNP 5 Dim0 10V 5 Dim0 10V 5 Dim0 10V black brown blue grey white Front view Top view P3 8 ...

Page 4: ...From 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Brightness D max t max f max 100 N A CW N A 100 to 240 1 5 30 ms 30Hz D Duty Cycle t pulse duration f frequency operatingConditions 10 to 40 C 14 to 104 F 80 of humidity without condensation No thermal shock max temperature variation 10 C 18 F in 24h Not for outdoor use The product is optimised for a lifespan 50kh in...

Page 5: ... mode Please consider a tolerance of 5 when measuring the dimmed bri ghtness levels STROBE INPUT STROBE INPUT STROBE INPUT 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 240 100 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 100 LED are supplied with 240 maximum current After 30ms LED are supplied at 100 level After 30ms LED are supp...

Page 6: ...e 24V in the light input 10 Max functioning Voltage 30V in the light input Max consumption Strobe signal 5mA Installation Guidance Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter to prevent the operators from approaching the lighting source beyond the recom mendations of the manufacturer If the workstation permits it introduc...

Page 7: ...ows less temperature build up at the LED junction The junction temperature of the LED is directly correlated with the lifetime of the LED chip Maximum ambient air temperature maximum 40 C 104 F LEDs naturally lose some intensity over time because of heat Using the dimming and setting a reference brightness is a method for keeping the brightness level constant over a very long time especially on br...

Page 8: ... 49 0 7542 5399 800 support wenglor com www wenglor com wenglor Straße 3 88069 Tettnang Germany Features and presentations liable to changes without notice Ref WOI 010201 A1 2022 03 edition ...

Reviews: