INTRODUCTION

RISk ClaSS

This Technical User Guide contains warnings and guidance for correct and safe operation of the product. 
These instructions must be followed at all times. wenglorTPL will not be held responsible for problems caused 
by using the product contrary to these instructions and the Warranty will be deemed invalid.

UNpaCkINg

This product is packed at the factory using suitable materials for safe transport. To open the package, do not use 
any cutting blade to avoid damaging the product(s). Please use the delivered  accessories if needed. (Do not use any 
other products or equivalents to replace the delivered accessories).

In the event of damage occurring during shipping, it must be reported to the carrier at time of delivery (including 
noting the damage in writing on the delivery documents). It is also your responsibility to notify wenglorTPL in wri-
ting of the damage within 24 hours of receipt of the package. If these instructions are not followed, wenglorTPL 
reserves the right not to accept requests for return and exchange of damaged products.

The applicable Standard EN-62471 classifies LED Lighting into 4 classes according to their degree of hazard severity. 
The table below summarises the risks associated with our standard products.

Color

Class

Risk

White WHI, Red 630 nm

0

none

IR 850 nm

1

low

lBaxxxx

OpeRaTINg INSTRUCTIONS

wenglorTPL can provide guidance notes to minimise photo-biological risks, including the nominal minimum 
operating distance. Please contact wenglorTPL through your usual representative for this information.

BewaRe to the infrared light, invisible to the eyes.
To know if the light is on, please refer to the LED indicators.

In all cases, wenglorTPL recommends 
the use of protection glasses.

Summary of Contents for LBA Series

Page 1: ...ge in writing on the delivery documents It is also your responsibility to notify wenglorTPL in wri ting of the damage within 24 hours of receipt of the package If these instructions are not followed wenglorTPL reserves the right not to accept requests for return and exchange of damaged products The applicable Standard EN 62471 classifies LED Lighting into 4 classes according to their degree of haz...

Page 2: ...ad the attachment points symmetrically along the bar You can also use M4 screws not supplied fastened directly into Aluminium profile with a tightening torque from 0 5 to 1 5 Nm We also recommend the use of a thread locker not supplied to avoid any risk of loosening LBAxxxx Operating instructions Total length mm Height mm Width mm Illumination length mm A B C D LBAx101 158 45 47 6 125 LBAx201 283 ...

Page 3: ...5 male points 24V 1 2 3 4 Ground PNP 5 Dim0 10V STROBEPNP 24V NPN 1 2 3 4 Ground STROBENPN 24V 1 2 3 4 Ground PNP 24V NPN 1 2 3 4 Ground CONTINUOUSMODE or 2 4 1 24V 3 GND 5 DIM0 10V STROBE NPN STROBE PNP 5 Dim0 10V 5 Dim0 10V 5 Dim0 10V black brown blue grey white Front view Top view P3 8 ...

Page 4: ...From 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Brightness D max t max f max 100 N A CW N A 100 to 240 1 5 30 ms 30Hz D Duty Cycle t pulse duration f frequency operatingConditions 10 to 40 C 14 to 104 F 80 of humidity without condensation No thermal shock max temperature variation 10 C 18 F in 24h Not for outdoor use The product is optimised for a lifespan 50kh in...

Page 5: ... mode Please consider a tolerance of 5 when measuring the dimmed bri ghtness levels STROBE INPUT STROBE INPUT STROBE INPUT 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 240 100 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 100 LED are supplied with 240 maximum current After 30ms LED are supplied at 100 level After 30ms LED are supp...

Page 6: ...e 24V in the light input 10 Max functioning Voltage 30V in the light input Max consumption Strobe signal 5mA Installation Guidance Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter to prevent the operators from approaching the lighting source beyond the recom mendations of the manufacturer If the workstation permits it introduc...

Page 7: ...ows less temperature build up at the LED junction The junction temperature of the LED is directly correlated with the lifetime of the LED chip Maximum ambient air temperature maximum 40 C 104 F LEDs naturally lose some intensity over time because of heat Using the dimming and setting a reference brightness is a method for keeping the brightness level constant over a very long time especially on br...

Page 8: ... 49 0 7542 5399 800 support wenglor com www wenglor com wenglor Straße 3 88069 Tettnang Germany Features and presentations liable to changes without notice Ref WOI 010201 A1 2022 03 edition ...

Reviews: