GENERATOR PREPARATION
For subsequent operation, the oil level should be checked before each use, or after every 8 hours of opera-
tion. The generator is equipped with a low-oil sensor and will NOT start without a sufficient amount of oil.
Upper Limit
Lower Limit
Fig. 4
To check oil level (before every subsequent start):
1. Place the generator on a level surface. Make sure the engine is OFF
before adding or checking oil.
2. Remove and wipe the dipstick with a clean rag.
3. Insert the dipstick into the oil fill without screwing it in. Remove the
dipstick to check the oil mark (Fig. 4).
If the oil mark covers less than one half of the dipstick, slowly add oil
until the oil mark reaches to the top of the dipstick (or when you can
see the oil coming halfway up the oil fill threads).
4. Wipe clean any oil leaks and firmly tighten the dipstick.
OIL LEVEL SHUTDOWN
To protect the unit from damage, the generator is equipped with a low-oil-pressure shutoff that will automati-
cally shut down the engine when the oil level is too low. The oil level of the engine should be checked before
each start to ensure that the engine crankcase contains sufficient lubricant.
13
TIP:
Your WEN generator is compatible with the
WEN 55201
Magnetic Oil Dipstick (not included), avail-
able for purchase at
wenproducts.com
. The dipstick’s industrial-strength magnetic tip will collect metal
shavings from your generator’s oil tank to help preserve the engine and extend your generator’s lifespan.