17
Device Requirements
Max. Cord Length (ft) by Wire Gauge
Amps
Watts (120V) Watts (240V)
#8 wire
#10 wire
#12 wire
#14 wire
#16 wire
2.5
300
600
NR
NR
NR
375
250
5
600
1200
NR
NR
300
200
125
7.5
900
1800
NR
350
200
125
100
10
1200
2400
NR
250
150
100
50
15
1800
3600
NR
150
100
65
NR
20
2400
4800
175
125
75
50
NR
25
3000
6000
150
100
60
NR
NR
30
3600
7200
125
65
NR
NR
NR
40
4800
9600
90
NR
NR
NR
NR
CAUTION:
Do not connect 50Hz loads to the generator.
SOME NOTES ABOUT POWER CORDS
Long or thin cords can drain the power provided to an electrical device by the generator. When using such cords,
allow for a slightly higher rated wattage requirement by the electrical device.
USING THE GENERATOR
*NR = Not Recommended
If an overload occurs, shut down the generator. Unplug all electrical devices and wait five minutes. Then, start the
unit back up again to get power back.
120V Duplex
Receptacle
Ground
Voltage
Selector
Fig. 8 - Control Panel
120V/240V
Receptacle
(L14-30)
DC 12V/8.3A
Receptacle
Circuit Breaker