background image

10

1. Make sure you are in distance measuring mode depicted by the arrow symbol       . If you’re in a different mode, 

press the mode button       until you see the arrow symbol on the screen.

2. Make sure to set your measuring device’s reference point and units (see p. 8).

3. Hold down the measurement button         for two seconds. You are now in continuous measuring mode. As the 

distance between the reference point and target point changes, the measurement will update on the screen and 

you will hear a tone. Press the measurement button to exit continuous measuring mode.

NOTE: 

The device will not save the measurements while you are in continuous measuring mode. The laser stays 

on the duration of the continuous measurement. DO NOT shine the laser towards people or animals.

MEASURING VOLUME

The volume measuring function is made for measuring the volume of a rectangular prismatic space. This function 

is depicted by the cube symbol      . 

OPERATION

       

WARNING:

 Do not direct the laser beam at persons or animals. Do not stare into the direct or reflected 

laser beam, not even from a distance. Looking into the laser beam or directing the laser beam into someone’s 
eyes can cause eye damage, blindness, and cause accidents.

1. Make sure you are in volume measuring mode depicted by the 

cube symbol      . If you’re in a different mode, press the mode button       

until you see the cube symbol on the screen.

2. Make sure to set your measuring device’s reference point and units 

(see p. 8).

3. If the laser beam is not ON, press the measurement button         to 

activate the laser. You will see the laser icon     in the top left corner 

when the laser is activated. Aim the laser to measure the length. Press 

the measurement button         again to take the measurement. The 

value will be seen on your display. 

4. Repeat step 3 two more times to measure the width, and height. 

The volume will automatically calculate after the third measurement is 

taken. The value of the last measurement will be seen on the top row 

of your screen and the volume will be on the bottom. Your screen will 

look like Fig. 6.

NOTE: 

A line will appear on the edge of the volume symbol to 

indicate which measurement you are recording.

CONTINUOUS MEASURING

The continuous measuring setting allows you to move the device and 

receive updated measurements every few seconds.

Fig. 6 

NOTE: 

The laser will automatically 

shut off after 30 seconds of inactiv-

ity to prolong battery life and limit 

accidents.

NOTE:

 The bottom number on your 

display is the current measurement 

being recorded. If you take multiple 

measurements, the previous mea-

surement moves to the top row.

Laser ON/OFF

Volume Mode

Battery 

Level

Units

Previous

Measurement

Volume

Summary of Contents for 10165

Page 1: ...ormance Pay close attention to the rules for safe operation warnings and cautions If you use your device properly and for its intended purpose you will enjoy years of safe reliable service IMPORTANT MODEL 10165 65 FOOT LASER DISTANCE MEASURE NEED HELP CONTACT US Have product questions Need technical support Please feel free to contact us at NOTICE Please refer to wenproducts com for the most up to...

Page 2: ...nance 14 Troubleshooting Guide 15 Exploded View Parts List 16 Warranty Statement 18 SPECIFICATIONS Model Number 10165 Laser Type 650 nm 1 mW Laser Class II Battery 2 AAA Batteries not included Operating Temperature 14 F 104 F Measuring Distance 65 feet Measuring Accuracy 3 0 mm 1 8 inch Measuring Distance 0 16 65 5 feet Weight 3 5 oz with batteries Dimensions 1 5 8 x 1 x 4 3 8 inches ...

Page 3: ...not meant to cover all possible conditions and situations that may occur WEN reserves the right to change this product and specifications at any time without prior notice Keep this manual available to all users during the entire life of the device and review it frequently to maxi mize safety for both yourself and others SAFETY ALERT SYMBOL Indicates danger warning or caution The safety symbols and...

Page 4: ...must deliberately close your eyes and immediately turn your head away from the beam 4 Never point the laser beam towards reflecting surfaces Never point the laser towards people or animals Even a laser beam with a low output can cause damage to the eyes 5 Do not allow children to use the laser measuring tool They could unintentionally blind other persons or them selves 6 Device inspection Before o...

Page 5: ...lacement parts before resuming operation 11 Do not leave the switched on measuring device unattended Switch the measuring tool OFF after use Other persons could be blinded by the laser beam 12 Protect the measuring device against moisture and direct sunlight Store in a dry shaded location Do not store at temperatures lower than 14 F or higher than 104 F 13 Do not subject the measuring device to ex...

Page 6: ...e Measure DISPLAY FUNCTIONS Use the diagram to the right to learn about the various icons on your laser distance measure A Laser ON OFF B Length Measurement C Area Volume Measurement Area Volume D Error Service Needed E Battery Level F Measurement Reference Top Base G Previous Measurement Value H Current Measurement Area Volume I Unit m ft in Laser Beam Outlet DO NOT POINT AT EYES Battery Cover Re...

Page 7: ...e chargeable batteries not included NOTE More measurements are possible when using 1 5V rechargeable batteries rather than 1 2V rechargeable batteries 1 Push the tab Fig 1 1 inwards and pull upwards to remove the bat tery cover Fig 1 2 2 Insert two AAA batteries not included into the battery compartment Fig 1 3 Follow the diagram inside of the battery compartment to place the batteries in the corr...

Page 8: ...the laser beam at persons or animals Do not stare into the direct or reflected laser beam not even from a distance Looking into the laser beam or directing the laser beam into someone s eyes can cause eye damage blindness and cause accidents SELECTING THE MEASURING REFERENCE POINT You can set your measuring device to measure from either the base of the unit or from the top of the unit See Figures ...

Page 9: ... symbol 1 Make sure you are in area measuring mode depicted by the area symbol If you re in a different mode press the mode button un til you see the area symbol on the screen 2 Make sure to set your measuring device s reference point and units see p 8 3 If the laser beam is not ON press the measurement button to activate the laser You will see the laser icon in the top left corner when the laser ...

Page 10: ...olume measuring mode depicted by the cube symbol If you re in a different mode press the mode button until you see the cube symbol on the screen 2 Make sure to set your measuring device s reference point and units see p 8 3 If the laser beam is not ON press the measurement button to activate the laser You will see the laser icon in the top left corner when the laser is activated Aim the laser to m...

Page 11: ...tery from dam age do not store at temperatures lower than 14 F or higher than 104 F Remove the batteries before storing for an extended period of time DISPOSAL When the product reaches the end of its lifetime please do not dispose of it with household waste Electrical and electronic products are hazardous to the environment and human health due to the presence of hazardous substances Take the prod...

Page 12: ...MATION 1 The reception lens and the laser beam outlet must not be covered when taking a measurement 2 You must hold the measuring device still while taking a measurement except when you are using the continu ous measurement function 3 The measurement reported is the distance to the center of the laser dot even if the target surface is angled 4 Once you select your measuring reference point align t...

Page 13: ...ing Screw Socket Head 1 4 10165 004 Large Battery Plate 1 5 10165 005 Positive Plate 1 6 10165 006 Negative Plate 1 7 10165 007 Back Cover 1 No Part No Description Qty 8 10165 008 Laser Module 1 9 10165 009 Screw 2 10 10165 010 Cross Head Screw 4 11 10165 011 PCB 1 12 10165 012 Display Screen 1 13 10165 013 Button Pad 1 14 10165 014 Front Cover 1 15 10165 015 Panel Board 1 ...

Page 14: ...ve parts and products may need to be sent to WEN before the replacements can be shipped out Upon the confirmation of a WEN representative your product may qualify for repairs and service work When re turning a product for warranty service the shipping charges must be prepaid by the purchaser The product must be shipped in its original container or an equivalent properly packed to withstand the haz...

Page 15: ...NOTES 15 ...

Page 16: ...THANKS FOR REMEMBERING ...