- 26 -
Installation manual
M-WRG-M/MB-FK1 / FK2
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L AT I O N & H E AT R E C O V E R Y
9.19
Sealing ventilation pipes on external wall
NOTE
If the external plaster encloses the ventilation
pipes all round and without gaps, you can skip the
steps described in this section.
►
Chamfer both pipe breakthrough edges
(item 1 in Fig. 30) to roughly 5x45° to cre-
ate enough space for the sealing joints with
permanently elastic sealant.
►
Fill the chamfers of the pipe breakthrough
edges all-round with permanently elastic
sealant on the outside.
NOTE
►
Only use a solvent-free sealant if the sealant is applied to polystyrene.
9.20
Attaching the outer wall terminal
WARNING
Do not run without the outer wall terminal.
►
Please note that the ventilation unit must
not be used without the outer wall terminal
for safety reasons.
►
Attach the outer wall terminal to the outer
wall.
NOTE
Installation of the outer wall terminal is described
in the separate installation manual “Outer wall
terminals M-WRG-ES...”, part no. 5300-20-01.
Fig. 30:
Sealing ventilation pipes on the
external wall
Fig. 31:
Attaching the outer wall terminal