OBTAINING SERVICE

If the 

AmeriCool by Weltem Portable Dehumidifier

 requires Service:

1.  Use the TROUBLESHOOTING section in this manual to eliminate obvious causes.

2. Verify there are no circuit breakers tripped.

3.  Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the 

problem, call 

AmeriCool by Weltem Portable Dehumidifier 

Technical Support at 888-726-

6158 Please have the following information available BEFORE calling the Technical Support De-

partment:

a. Your name and address.

b. The serial number of the unit.

c. Where and when the unit was purchased.

d.  All of the model information about your 

AmeriCool by Weltem Portable Dehumidifier.

e.  Any information on the failure, including LED’s that may or may not be illuminated.

f.  A description of the protected equipment, including model numbers if possible.

SHIPPING LIST

• (1) PORTABLE DEHUMIDIFIER
• (1) Owner’s Manual
• (1) POWER CORD HOLDER
• (1) Metal handle / Drain hose

Summary of Contents for AmeriCool WPD-120

Page 1: ...ed Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference Americool by Weltem Portable Dehumidifier feature strong dehumidification performance for large areas where high humidity causes serious problems such as corrosion decay and odor The dedicated dehumidi...

Page 2: ...ays place the unit on an even level surface 3 Ensure the unit is connected to a grounded power supply of the correct rating capacity 4 The unit is designed to operate under 5 C 41 F 35 C 95 F and RH maximum 80 5 DO NOT use this unit for functions other than those described in this instruction manual 6 DO NOT tilt the unit 7 DO NOT cover or obstruct the unit s inlet and outlet grilles 8 DO NOT use ...

Page 3: ...able environments DO NOT operate a unit with a damaged power cord 19 The filters must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has been turned off and unplugged from the electrical outlet 20 Regularly clean the filters to maintain efficiency If the filters are not cleaned regularly the units output performance and efficiency will ...

Page 4: ...ilter Caster It makes the unit easy to move Condensate outlet It is where condensate comes out connected to drain pump 바이어명 Model 디스플레이 PART NO 1D R icen02616 제습기디스플레이국문 아이센 제습기 전제품 라벨 사이즈 129x74 적용모델 이동식에어컨 국내제습기 2016 04 19 신규 작 성 검 토 확 인 수정사항 1 2 3 4 5 6 7 8 1 2 3 4 5 1 재질 2 인쇄방법 스크린인쇄 3 인쇄색상 5도 4 표면처리 라미네이팅 OPP코팅 5 인쇄기준 도면 및 설계 제공 필름 6 외곽의 치수선 붉은선 은 인쇄후 절단선임 현재습도 온도 설정습도 온도 알 람 전원 송풍 제습 예약 Drai...

Page 5: ...or any other foreign material The unit is equipped with an approved NEMA plug configuration WPD 120 5 15P The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in areas where flammable gas leakage may occur Do not use the unit in areas where it will be exposed to rain or water Do not use the unit ...

Page 6: ...off when it is not on dehumidification mode It is controlled based on dehumidification sensor and relative humidity is displayed 2 Humidity measured on display 0 99 3 Setting range 20 80 Setting range is controlled by UP and DOWN button It is either increased or decreased by 5 3 When the gap between current temperature and target humidit is over 15 High mode works When less than 15 Low mode works ...

Page 7: ...ressing dehumidification button or selecting set time During setting mode user controls setting range by pressing the UP and DOWN button Setting range 0 12 hrs it is either increased or decreased by 30mins Current humidity Setup humidity TEMP 1 Current humidity and Target humidity are displayed 2 How to see temperature Press the blower and dehumidification button at the same time for a second then...

Page 8: ... the filter in a shaded area before replacing it Do not operate the unit without the filter installed and the filter guard in the closed position 5 Replace the clean filter and close the filter grill To remove front filter pulling up filter flame Slide filter up and use a vaccum cleaner to remove the dust from the filter Remove dust from the filter using a vacuum cleaner hose attachment if require...

Page 9: ...manual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is activated if abnormal operation occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is rectified within 3 minutes the unit will resume opera tion If...

Page 10: ... ⷄ NCJFOU UFNQFSBUVSF JT UPP IJHI ⷄ NCJFOU UFNQFSBUVSF JT UPP IJHI ⷄ 6OTUBCMF WPMUBHF TVQQMZ ⷄ FGFDUJWF DPNQSFTTPS ⷄ 0WFS DVSSFOU SFMBZ EFGFDU PS CSPLFO DPOOFDUJPO 5 EFIVNJEJGJDBUJPO TFOTPS IBT B MPPTF PS CSPLFO DPOOFDUJPO ⷄ P OPU VTF UIF BJS DPOEJUJPOFS JG BNCJFOU UFNQFSBUVSF JT IJHIFS UIBO ⳃ ⷄ POUBDU B RVBMJGJFE TFSWJDF BHFOU ⷄ 3FQMBDF DPNQSFTTPS POUBDU B RVBMJGJFE TFSWJDF BHFOU 5 0VUMFU UFNQFSB...

Page 11: ...Circuit Wiring Diagram WPD 120 2017 07 20 신규 수정사항 1 2 3 4 5 7 8 9 1 재질 은무데등롱지 25미크론 2 인쇄방법 씨링인쇄 3 인쇄색상 흑색1도 4 표면처리 라미네이팅 OPP코팅 5 인쇄기준 도면 및 설계 제공 필름 6 외곽의 치수선 붉은선 은 인쇄후 절단선임 WPD 180 210 0 6 CURRENT TEMP HUMID TARGET TEMP HUMID POWER BLOWER DEHUMID TIMER ...

Page 12: ...12 WPD 120 Owner s Manual ...

Page 13: ...13 WPD 120 Owner s Manual ...

Page 14: ...ifier Technical Support at 888 726 6158 Please have the following information available BEFORE calling the Technical Support De partment a Your name and address b The serial number of the unit c Where and when the unit was purchased d All of the model information about your AmeriCool by Weltem Portable Dehumidifier e Any information on the failure including LED s that may or may not be illuminated...

Page 15: ...15 WPD 120 Owner s Manual ...

Page 16: ...n vi modifications or alterations to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installation or service ix shipping damage to any units or spare parts during shipping This includes and is not limited to compres sors evaporators and condenser coils This warranty shall extend only to the original end user and shall be void if any labels or other id...

Reviews: