WELTECH BW-2050 Manual Download Page 9

REMOTE

 

COMMANDS

 

The following commands are accepted at the serial port. 

ID? 

   Send 

id 

message 

ALL? 

 

   Send 

ver cal every bird list for current store 

WGT?   Send 

current 

weight 

DATA? 

 

 

Send summary report for current store 

HYST? 

 

 

Send histogram for current report 

TARG?   Send 

target 

weight 

TARG,nnnn      

 

Set target weight 

DUMP? 

  Send 

all 

weights 

STATS   Send 

sta s cs summary 

SER? 

   Send 

serial 

number 

EACH  

 

 

Turns on the each bird print 

EAOFF   Turns 

o

 the each bird print 

HYON 

 

 

Turns on the histogram print 

HYOFF   Turns 

o

 histogram print 

STON 

   Turns 

on 

sta s c print 

STOFF   Turns 

o

 the sta s c print 

UP   

 

 

Send bird dump in binary Data Pod format 

DATE? 

 

 

Send the date ddmmyy 

TIME?   Send 

the 

me hhmm 

DATE,ddmmyy      

Set the date ddmmyy 

TIME,hhmm           

Set the  me hhmm 

CLEAR   Clear 

memory 

PRINT   Print 

standard 

reports 

SETTS   Print 

se ngs report 

RESET   Restart 

the 

processor 

OFF 

   Power 

down 

16 

USING

 

THE

 

USB

 

Turn weigher on and open 

PRINT

 

OPTIONS

, and make sure 

WRITE

 

TO

 

USB

 

is on.  

Plug USB s ck into port (Shown on page 15) and press 

PRINT

 

DATA

Once the 

fi

le is wri en 

FILE

 

WRITTEN

 

OK

 

will appear on the screen, the 

data is now downloaded. Remove the USB s ck from the weigher and 
plug into your computer. 

Go to 

MY

 

COMPUTER

 

and open 

USB

 

DISK

 

FILES

. Now select all the 

fi

les 

and right click, a small dropdown menu should appear with the op on 

OPEN

 

WITH..

 

now select 

CHOOSE

 

DEFAULT

 

PROGRAM

 

and select      

MICROSOFT

 

EXCEL

Or 

Open Microso  Excel. Select 

FILE

 in the top le  corner and then click 

OPEN

. It will now open a small window, click on 

MY

 

COMPUTER

 

and 

select the 

USB

 

DISK

 

icon. Select all the 

fi

les you want to see and then 

click open. (You selected mul ple 

fi

les by holding down 

CTRL

 and     

clicking each 

fi

le) 

17 

Summary of Contents for BW-2050

Page 1: ...and will retain all weights even when the ba ery is flat The BW 2050 can store up to 5000 bird weights Weights can be placed into 1 50 separate stores All informa on is stored un l the CLEAR sequence has been completed The maximum weight the unit can weigh is 10kgs 22lbs for the chicken version and 50kgs 110lbs for the turkey weigher BW 2050 Control Panel Printer Computer and USB op onal ports are...

Page 2: ...hows 0 000 KGS if not press TARE Power off the weigher and a ach the shackle Power on the weigher and press the TARE key The weigher will tare out the shackle weight and show 0 000 KGS This tared weight will stay in the weigher un l another tare is done SETUP OPTIONS To reset the weigher back to Factory se ngs hold the MEMORY STORE bu on and turn on The display will show WELTECH SET UP un l the bu ...

Page 3: ...is sent to the printer and can be changed using the INC or DEC bu ons Baud rate for serial port BLUETOOTH H SHK OFF Not an available op on PRINTER H SHK OFF This is not used with our printer PRINTER LINEFEED ON Sends line feed to printer after a new line PRINTER DELAY 0 1 SECS This is the delay time from pressing the print data button to the actual print function WEIGHT RANGE Chicken or Turkey To ...

Page 4: ... LOW LIMIT 0 050 Lower acceptance limit HIDE DISPLAY OFF Hides the weight when ready AUTO ZERO FILTER 6 Drives the display towards zero at low weights Do not alter VOLTAGE FILTER 6 Ba ery voltage filter steepness Do not alter DIVISIONS 1 Where a number of birds are being weighed together the program can be set to divide by the number of birds to give an average DEVIATION METHOD WELTECH Universal s...

Page 5: ... bu on To clear data already stored in the weigher press CLEAR the display will then ask you to press ENTER a er this the display will then ask you to confirm by pressing SET UP to escape press CLEAR Data will remain in the memory un l cleared The display will then show STORE 1 Ba ery charge indicator Time Select the house the weights are to be stored in by pressing MEMORY STORE press the INC or D...

Page 6: ...in the USB s ck Press the PRINT DATA key and the display will show WRITING TO USB When the weigher has finished the display will flash up FILE WRITTEN OK and the display will go back to the standard weighing display The USB s ck can now be removed and used on a computer If there is no USB s ck in the weigher when you try to write to the USB the display will show WRITING TO USB followed by NO STICK...

Page 7: ...ed in the weigher will remain in memory even if the unit automa cally turns off To recharge the ba eries fully leave on charge over night To check the ba ery voltage or charging voltage Hold the SET UP bu on down and turn ON the display will show WELTECH SET UP then DATA STORES press CLEAR and then the INC key If the INC or DEC key is pushed the display will show the date me and ba ery charge By pu...

Page 8: ...INT DATA Prints data INC DEC Increase se ngs Decrease se ngs CLEAR Clear data stored SET UP Engineers se ngs SET BANDS Set grading bands or target weights FAST SLOW Selects between fast or slow weighing PRINT OPTIONS Set type of printout Sta s cs Histogram Each ENTER Enters data into store command CAL Sets zero tare and calibra on Charging Socket RS232 Output Printer Computer USB STICK Socket if f...

Page 9: ... CLEAR Clear memory PRINT Print standard reports SETTS Print se ngs report RESET Restart the processor OFF Power down 16 USING THE USB Turn weigher on and open PRINT OPTIONS and make sure WRITE TO USB is on Plug USB s ck into port Shown on page 15 and press PRINT DATA Once the file is wri en FILE WRITTEN OK will appear on the screen the data is now downloaded Remove the USB s ck from the weigher a...

Page 10: ...ed in water Carrying the unit by the hook may cause damage to the loadcell and stop you from weighing This unit is fi ed with rechargeable ba eries and will last for 3 4 years INDEX Subject Page Introduc on 1 Calibra on 2 Setup Op ons 3 Operator Se ngs 4 Opera ng Instruc ons 9 Printer Output 12 Charging 13 Key Pad 14 PC Opera on 15 Remote Commands 16 Using The USB 17 Safety Considera ons 18 ...

Page 11: ...ts opera on and reliability and give our customers a product that suits their requirements SERVICE For service and repairs contact your local agent Weltech Interna onal Limited 10 Bramley Road St Ives Cambridgeshire PE27 3WS Email info weltech co uk Tel 44 0 1480 461611 Fax 44 0 1480 301010 Weltech Interna onal Limited ...

Reviews: