![WELTECH BW-2050 Manual Download Page 4](http://html.mh-extra.com/html/weltech/bw-2050/bw-2050_manual_956076004.webp)
STABILITY
10
Repe
ons within stability jump limit.
Do not alter.
STABILITY
JUMP
5
Varia on in ADC count considered stable
do not alter.
WEIGHT
FILTER
3
Filters out movement on the weigher
FILTER
JUMP
0
Filters out excessive sharp movements
on the weigher
WEIGHT
FREEZE
ON
Shows accepted weight un l ready
EVENNESS
10%
Percentage above and below average
for sta s cs
HIGH
LIMIT
9.999
Upper acceptance limit
LOW
LIMIT
0.050
Lower acceptance limit
HIDE
DISPLAY
OFF
Hides the weight when ready
AUTO
ZERO
FILTER
6
Drives the display towards zero at low weights
Do not alter.
VOLTAGE
FILTER
6
Ba ery voltage
fi
lter steepness
Do not alter.
DIVISIONS
1
Where a number of birds are being weighed
together the program can be set to divide
by the number of birds to give an average
DEVIATION
METHOD
WELTECH
Universal standards (Weltech)
Bernard Ma hews standard
FAST
MODE
OFF
Selects the speed the weigher starts up in.
LANGUAGE
ENGLISH
Selects the language the weigher starts up in.
(English, Spanish, French or Portuguese)
6
7