background image

Weltech Interna onal Limited 

      

BW

2050

 

Manual

 

INTRODUCTION

 

The BW

2050 has been designed to give the operator complete          

fl

exibility for manual live bird weighing. The BW

2050 is ba ery           

operated and will weigh for up to 15 hours between recharging and    
will retain all weights even when the ba ery is 

fl

at. 



The BW

2050 can store up to 5000 bird weights.  



Weights can be placed into 1

50 separate stores.  



All informa on is stored un l the 

CLEAR

 sequence has been    

completed. 

The maximum weight the unit can weigh is 10kgs (22lbs) for the chicken 

version and 50kgs (110lbs) for the turkey weigher. 

 

 

BW

2050

 

Control

 

Panel

  

 

 

 

 

 

 

 

 

 

Printer, Computer and USB (op onal) ports are on the side 

Picture is of BW

2050 Full kit 

Summary of Contents for BW-2050

Page 1: ...and will retain all weights even when the ba ery is flat The BW 2050 can store up to 5000 bird weights Weights can be placed into 1 50 separate stores All informa on is stored un l the CLEAR sequence has been completed The maximum weight the unit can weigh is 10kgs 22lbs for the chicken version and 50kgs 110lbs for the turkey weigher BW 2050 Control Panel Printer Computer and USB op onal ports are...

Page 2: ...hows 0 000 KGS if not press TARE Power off the weigher and a ach the shackle Power on the weigher and press the TARE key The weigher will tare out the shackle weight and show 0 000 KGS This tared weight will stay in the weigher un l another tare is done SETUP OPTIONS To reset the weigher back to Factory se ngs hold the MEMORY STORE bu on and turn on The display will show WELTECH SET UP un l the bu ...

Page 3: ...is sent to the printer and can be changed using the INC or DEC bu ons Baud rate for serial port BLUETOOTH H SHK OFF Not an available op on PRINTER H SHK OFF This is not used with our printer PRINTER LINEFEED ON Sends line feed to printer after a new line PRINTER DELAY 0 1 SECS This is the delay time from pressing the print data button to the actual print function WEIGHT RANGE Chicken or Turkey To ...

Page 4: ... LOW LIMIT 0 050 Lower acceptance limit HIDE DISPLAY OFF Hides the weight when ready AUTO ZERO FILTER 6 Drives the display towards zero at low weights Do not alter VOLTAGE FILTER 6 Ba ery voltage filter steepness Do not alter DIVISIONS 1 Where a number of birds are being weighed together the program can be set to divide by the number of birds to give an average DEVIATION METHOD WELTECH Universal s...

Page 5: ... bu on To clear data already stored in the weigher press CLEAR the display will then ask you to press ENTER a er this the display will then ask you to confirm by pressing SET UP to escape press CLEAR Data will remain in the memory un l cleared The display will then show STORE 1 Ba ery charge indicator Time Select the house the weights are to be stored in by pressing MEMORY STORE press the INC or D...

Page 6: ...in the USB s ck Press the PRINT DATA key and the display will show WRITING TO USB When the weigher has finished the display will flash up FILE WRITTEN OK and the display will go back to the standard weighing display The USB s ck can now be removed and used on a computer If there is no USB s ck in the weigher when you try to write to the USB the display will show WRITING TO USB followed by NO STICK...

Page 7: ...ed in the weigher will remain in memory even if the unit automa cally turns off To recharge the ba eries fully leave on charge over night To check the ba ery voltage or charging voltage Hold the SET UP bu on down and turn ON the display will show WELTECH SET UP then DATA STORES press CLEAR and then the INC key If the INC or DEC key is pushed the display will show the date me and ba ery charge By pu...

Page 8: ...INT DATA Prints data INC DEC Increase se ngs Decrease se ngs CLEAR Clear data stored SET UP Engineers se ngs SET BANDS Set grading bands or target weights FAST SLOW Selects between fast or slow weighing PRINT OPTIONS Set type of printout Sta s cs Histogram Each ENTER Enters data into store command CAL Sets zero tare and calibra on Charging Socket RS232 Output Printer Computer USB STICK Socket if f...

Page 9: ... CLEAR Clear memory PRINT Print standard reports SETTS Print se ngs report RESET Restart the processor OFF Power down 16 USING THE USB Turn weigher on and open PRINT OPTIONS and make sure WRITE TO USB is on Plug USB s ck into port Shown on page 15 and press PRINT DATA Once the file is wri en FILE WRITTEN OK will appear on the screen the data is now downloaded Remove the USB s ck from the weigher a...

Page 10: ...ed in water Carrying the unit by the hook may cause damage to the loadcell and stop you from weighing This unit is fi ed with rechargeable ba eries and will last for 3 4 years INDEX Subject Page Introduc on 1 Calibra on 2 Setup Op ons 3 Operator Se ngs 4 Opera ng Instruc ons 9 Printer Output 12 Charging 13 Key Pad 14 PC Opera on 15 Remote Commands 16 Using The USB 17 Safety Considera ons 18 ...

Page 11: ...ts opera on and reliability and give our customers a product that suits their requirements SERVICE For service and repairs contact your local agent Weltech Interna onal Limited 10 Bramley Road St Ives Cambridgeshire PE27 3WS Email info weltech co uk Tel 44 0 1480 461611 Fax 44 0 1480 301010 Weltech Interna onal Limited ...

Reviews: