background image

Here are the SS7 parameters that Wellgate 5290 need. 
 
- E1 Information: 
     Line code 
     Framing Method 
      Clocking Source 
 
- SS7 Information: 
     - Point Code assigned to   Wellgate 5290 
      - Destination point code 
      - Adjust Point Code if any 
      - CIC number for each trunk 
      - ITUT white book or blue book 
      - Any country variance 
      - SS7 time slot 
      - Does the SS7 include voice channel or not 
 
 
Example: 

E1 information 
Line code                       HDB3 
Clocking Source             First E1 
Framing                         CRC4 E1 framing

 

  

SS7 Information 
Switch type                    Q767 
OPC                              4118 
DPC                              5122 
STP                               5089 
Time Slot                       1 of the 1st E1 
Starting CIC                    2 
Number of Circuits          119 
CIC to Skip                     16,32,48,64,80,96,112,128 
SS7 Variant                    Base Only 
Network Indicator            International 
SS7 include voice channel

 

 