a. Failure to do will result in the solenoid not engaging and as a result no water will pass
through the filters.
5. Connect a drain line to the output side of the TCR head. This will allow you to flush filters into a
bucket, or sink. Please see Blue water line placement in the picture below.
6. Turn the water on for 30 minutes.
7. Prior to turning off the water supply, ensure:
a. For RO only systems, the TDS is .02% vs the tap water TDS (98% reduction).
8. If you have issues achieving these readings, make sure you have 60-70 PSI feeding the system,
the drain is not restricted in any way including a reversed check valve, the inline flow restrictor
is in place and working properly and the unit is properly flushed. Please contact technical
support for further assistance.
14