GENERAL INSTALLATION DATA
PLACE THE LAMINATED WARNING SIGN SUPPLIED WITH THE FRYER IN AN
AREA VISIBLE TO THE FRYER OPERATOR.
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels associated with
the unit prior to putting it into operation. Make sure all people associated with its use understand the
units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This
unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If
equipment is received in damaged condition, either apparent or concealed, a claim must be made
with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a
request for inspection of concealed damage must be made with carrier within 15 days. Be certain to
retain all contents plus external and internal packaging materials for inspection. The carrier will make
an inspection and will supply necessary claim forms.
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE
"ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND
REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/
CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE
INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing the equipment.
This appliance and control valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 PSIG (1.034 ATM). This appliance
must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than
1/2 PSIG (1.034 ATM). For your protection, we recommend a qualified installing agency install this
appliance. They should be familiar with gas installations and your local gas requirements. In any
case, your gas company should be called to approve the final installation. In addition, there should be
posted, in a prominent location, detailed instructions to be followed in the event the operator smells
gas. Obtain the instructions from the local gas supplier.
FRYER SHOULD BE RESTRAINED TO PREVENT TIPPING WHEN INSTALLED
TO AVOID SPLASHING OF HOT LIQUID. USE ADEQUATE TIES WHEN
INSTALLING THE FRYER.
INAPPROPRIATE USE DUE TO A LACK OF COMMON SENSE MAY RESULT IN
PRODUCT DAMAGE OR PERSONAL INJURY.
CAUTION
CAUTION
CAUTION
Weight
Model
N.P.T. Gas
Dimensions
BTU
Connection
Installed
Shipped
Width
Depth
Height
G
F
15
30,000
3/8” (1cm)
64 lbs
75 lbs
12”
G
F
30
70,000
1/2” (2cm)
110 lbs
118 lbs
24”
25 1/8”
23 3/8”
Specifications