15
GB
Operation
Put the tool into operation as described in the
chapter „Placing into operation“.
Please adhere to the operating instructions of the
connected devices.
Check to see if the mains voltage matches the
ratings on the nameplate.
Make sure the machine is switched off before
plugging in.
Optimal gas filtration is achieved as follows:
• Temperature of process air in gas filter < 38 °C
• Relative humidity < 60 %
• Gas molecules > 30 g/mol (better filtration
results are achieved with larger molecules)
• Boiling point of the gas molecules > 0 °C
Caution!
A high noxious gas concentration will
cause the activated charcoal to heat up.
To avoid overheating, the unit should be
run without noxious gases for several
minutes before switching off.
Technical Data
Solder fume extraction
MG100S
MP140
Dimensions L x W x H
460 x 210 x 640 mm
18.1 x 8.3 x 25.2 inch
420 x 200 x 440 mm
16.5 x 7.8 x 17.3 inch
Weight
15 kg
8 kg
Max. extraction capacity
100 m³/h (58,8 CFM)
100 m³/h (58,8 CFM)
Compressor performance
140 m
3
/h (82,3 CFM)
140 m
3
/h (82,3 CFM)
Rated power consumption
100 W
100 W
Rated voltage
110-240 V / 50/60 Hz
110-240 V / 50/60 Hz
Glass tube fuse (5 x 20)
2 x 6,3 AT, 250 V
2 x 6,3 AT, 250 V
Operating sound level from 1 m distance
< 52 dB(A)
< 54 dB(A)
Combined filter
Combined E12 high
efficiency submicron filter
(99.95 % particle separati-
on upto 0.12 μm) and wide
band gas filter
(50 % activated carbon, 50
% Puratex)
Combined E12 high
efficiency submicron filter
(99.95 % particle separati-
on upto 0.12 μm).
Interface
The full range of system functions can be operated and
remotely monitored via the interface using an optional
interface adaptor.
Note
The unit may emit dust from the main filter
after transportation. Make sure that the unit is
put into service in a suitable room.
PK Elektronik Vertriebs GmbH, E-Mail: [email protected], Internet: www.pkelektronik.com