background image

Thank you for placing your trust in our company
by purchasing the Weller WHA900 Hot Air Station.
This product meets or exceeds the requirements
established by Weller for superior performance,
versatility and quality.

1. Cautions! / Warnings!

Please read these Operating Instructions and the
attached Safety Information carefully prior to initial
operation. Failure to observe the safety warnings
may result in accident, injury, or risk to health.

The manufacturer shall not be liable for damage
resulting from misuse of the machine or unautho-
rized alterations.

Warning:

This product when used for soldering

and similar applications, produces chemicals
known to the State of California to cause cancer
and birth defects or other reproductive harm.

Safety Information:

Always place the soldering iron in its original 

holder

Remove all inflammable objects from the prox-

imity of the hot soldering tool.

Use suitable protective clothing to prevent the

risk of burns associated with molten solder.

Never leave a hot soldering iron unattended.

Never work on electrically live circuits or com-

ponents.

Always wear eye protection when working with 

soldering and desoldering applications.

The Weller WHA900 Hot Air Station corresponds
to the EC Declaration of Conformity in accordance
with the basic safety requirements of Directives
89/336/EEC and 73/23EEC.

2. Description

The WHA900 hot air station was developed for
general soldering re-work on Surface Mount com-
ponents. The temperature of the hot air is con-
trolled electronically and is variable between
100°F and 1000°F. 120 VAC (8) is required to
operate the unit. The air flow is variable electroni-
cally within the range of approximately 5-50
l/minute and is generated by a self contained
pump. The hot air is activated using the Start/Stop
Push Button, (5) at the front of the unit.

The WHA900 is grounded through the 120 VAC
three wire power cord.

Standby mode:

This unit has a power-on function to activate a
Standby Mode (or secondary temperature airflow
setting). Before switching on the unit, choose the
Temperature and the Airflow settings that you
would prefer to use for the Standby Mode of oper-
ation.

Activating Standby:
Adjust the Temperature and Airflow control to the
desired Standby setting. Depress the Start/Stop
push button and hold while switching on the unit.
Keep the button depressed for approximately 5
seconds after turning the unit on. The pump will
start and the Standby function is activated. When
the unit is switched on, the Temperature and the
Airflow will be set to the Standby values. When
you depress the Start/Stop push button, the
Airflow and Temperature will go to the actual “Set”
values. The actual “Set” values should be set at a
normal Temperature and Airflow settings capable
of performing the rework application. Depress the
button again and the unit will go back to the
Standby values.

Note: To change the Standby settings, you must
first Deactivate Standby Mode as described
below.

Deactivating Standby:
If the Standby function is activated, depress the
Start/Stop push button while switching on the unit.
Keep the button depressed for about 5 seconds.
The unit is now in the original operating mode.
Repeat the “Activating Standby” directions to
assign new preferred settings.

3. Placing Into Operation

Note: Safety rest must be formed before tool use.

Place the hot air pencil in the formed safety rest
with the nozzle in a raised position to prevent
damage to work bench. Check to be sure the sup-
ply voltage is consistent with the information on
the station label. Before connecting to the 120
VAC power source, set the desired temperature
(2) and the air flow on (3) and switch on the unit
at the power switch (4). The LED will flash slowly
to indicate the unit has reached the Set
Temperature.

English      

2

Summary of Contents for WHA5R0FE

Page 1: ...WHA900 Operating Instructions ...

Page 2: ...Table of Contents Page WHA900 Detail View 1 Technical Data 1 1 Cautions Warnings 2 2 Description 2 3 Placing Into Operation 2 4 Operating Guidelines 3 5 Accessories 3 6 Packing List 3 7 Nozzles 4 5 6 ...

Page 3: ...ly 7 Fuse T 10 Amp 8 Receptacle 120 VAC Technical Data WHA900 Detailed View Dimensions 8 3 16 L 6 5 8 W 4 1 4 H Main Voltage 120 VAC Power consumption 750 WATTS Hot Air Pencil output 700 WATTS Fuse T 10 AMP Temperature Control Variable between 100 F and 1000 F Temperature Control accuracy 54 F Flow Control Variable between 5 50 l min Noise Level 56dB A distance 1m at max airflow level 1 ...

Page 4: ...p Push Button 5 at the front of the unit The WHA900 is grounded through the 120 VAC three wire power cord Standby mode This unit has a power on function to activate a Standby Mode or secondary temperature airflow setting Before switching on the unit choose the Temperature and the Airflow settings that you would prefer to use for the Standby Mode of oper ation Activating Standby Adjust the Temperat...

Page 5: ...rflow Knob to 4 Wait approximately 5 minutes before continuing 5 Read the temperature value indicated on the measuring instrument 6 If the temperature has to be corrected depress and hold the Start Stop push button for approximate ly 15 seconds while the hot air is activated The green LED 1 will light continuosly 7 While the green LED 1 is continuosly lit immediately turn the temperature knob slig...

Page 6: ...s 4 Ø 1 7 x 45 mm Ø 067 x 45 in 0058736882 Ø 2 5 mm Ø 098 in 0058736881 Ø 4 mm Ø 157 in 0058736867 Ø 7 mm Ø 280 in 0058736870 Ø 2 5 x 9 5 mm Ø 098 x 374 in 0058736883 Ø 11 5 mm Ø 453 in 0058736836 RD11 Made to Order ...

Page 7: ...83 in 0058736818 11 x 11 mm 433 x 433 in 0058736839 21 5 x 14 8 mm 846 x 583 in 0058736840 19 x 12 mm 748 x 472 in 0058736841 14 x 10 mm 551 x 394 in 0058736842 10 x 8 mm 394 x 315 in 0058736843 Measuring Nozzle 0058736875 Adapter 0058750722 ...

Page 8: ...1 23 in 0058736833 26 x 26 mm 1 024 x 1 024 in 0058736804 20 5 x 20 5 mm 807 x 807 in 0058736807 17 5 x 23 5 mm 689 x 925 in 0058750721 18 x 18 mm 709 x 709 in 0058736814 15 5 x 13 mm 610 x 512 in 0058736837 14 x 10 mm 551 x 394 in 0058736838 ...

Page 9: ...058736890 36 x 36 mm 1 417 x 1 417 in 0058736891 27 x 14 mm 1 063 x 551 in 0058736892 29 x 17 mm 1 142 x 669 in 0058736877 35 5 x 23 mm 1 398 x 906 in 0058736998 48 5 x 30 5 mm 1 909 x 1 201 in 0058736999 44 x 32 mm 1 732 x 1 260 in 0058736858 48 5 x 38 mm 1 909 x 1 496 in 0058750709 61 x 38 mm 2 402 x 1 496 in 0058750714 ...

Page 10: ...Hot Air Nozzles 8 Made To Order Nozzles Contact for Quote 12 x 27 mm 472 x 1 063 in 0058736880 38 x 38 mm 1 496 x 1 496 in 0058736890 40 x 40 mm 1 575 x 1 575 in 0058736891 ...

Page 11: ...d d T To oo ol ls s P O Box 728 Apex NC 27502 0728 U U S S S Sh hi ip pp pi in ng g A Ad dd dr re es ss s 1000 Lufkin Road Apex N C 27539 Tel 919 387 0099 Fax 919 387 2379 For inquiries concerning Technical Customer Service please call 800 476 3030 Ext 1 C Ca an na ad da a S Sh hi ip pp pi in ng g A Ad dd dr re es ss s C Co oo op pe er r T To oo ol ls s 164 Innisfil Street Barrie Ontario Canada L4...

Reviews: